| 1 | 6.13 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 : Cement mortar 1:4 (1 cement :4 coarse sand) |
| 2 | 11.5 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 3 | 11.38 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 4 | 9.20 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.9.20.1 : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 5 | 12.45.4 : Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineerin-charge and as per anufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 |
| 6 | 21.10 : Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 7 | 9.145 : Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineerin-charge. |
| 8 | 9.146 : Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles afterinserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of engineer-in-charge. |
| 9 | 13.43 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :13.43.1 : Water thinnable cement primer |
| 10 | 13.41 : Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :13.41.1 : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 11 | 13.42 : Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.13.42.1 : Two or more coats on new work. |
| 12 | 13.81 : Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.13.81.1 : Two coats |
| 13 | 13.85 : Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.13.85.3 : With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 14 | 13.98 : Wall painting with plastic emulsion paint of approved brand andmanufacture to give an even shade:13.98.1 : One or more coats on old work |
| 15 | 13.60 : Wall painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade :13.60.1 : Two or more coats on new work |
| 16 | 13.50 : Applying priming coat:13.50.2 : With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. |
| 17 | 13.62 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :13.62.1 : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 18 | 13.50 : Applying priming coat:13.50.3 : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 19 | 13.48 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.3 : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 20 | 13.47 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:13.47.1 : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 21 | 9.96 : Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :9.96.1 : 300x16 mm. |
| 22 | 9.97 : Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.1 : 300x10 mm. |
| 23 | 9.97.3 : 200x10 mm |
| 24 | 9.100 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.100.1 : 125mm |
| 25 | 9.100.2 : 100 mm |
| 26 | 9.100.3 : 75 mm |
| 27 | 4.17 : Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 28 | 19.3 : Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :19.3.5 : 300 mm diameter S.W. pipe Please Enable Macros to View BoQ information |