| 1 | SCHEDULE A PART I (BUILDING WORKS) |
| 2 | Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I . |
| 3 | SCHEDULE A PART II (INTERNAL WATER SUPPLY) |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch ‘A’ Part II. |
| 5 | SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS) |
| 6 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONS as listed in Sch ‘A’ Part III. |
| 7 | SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) |
| 8 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch ‘A’ Part IV . |
| 9 | SCHEDULE A PART V (EXTERNAL ELECTRIFICATION) |
| 10 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION as listed in Sch ‘A’ Part V |
| 11 | SCHEDULE A PART VI (SEWAGE DISPOSAL) |
| 12 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Sch ‘A’ Part VI |
| 13 | SCHEDULE A PART VII (BOUNDRY WALL, FENCING AND GATE) |
| 14 | Lump sum price worked out by the contractor for BOUNDRY WALL, FENCING AND GATE as listed in Sch ‘A’ Part VII |
| 15 | SCHEDULE A PART- VIII (AIR CONDITIONER AND REGRIGERATION WORKS) |
| 16 | Lump sum price worked out by the contractor for (AIR CONDITIONER AND REGRIGERATION WORKS) as listed in Sch ‘A’ Part VIII |
| 17 | SCHEDULE A PART- IX EARTH WORK) |
| 18 | Lump sum price worked out by the contractor for (EARTH WORK) as listed in Sch ‘A’ Part IX |
| 19 | SCH \\"A\\" PART X (MISCELLENEOUS B/R AND E/M ITEMS) |
| 20 | Supply and fix for, flame proof, weather proof enclosure made of cast aluminium alloy LM6 weather proof IP65, finished inside and outside with light grey epoxy powder coating for MCB distribution board, single phase and neutral, with incoming and outgoing terminal chamber, copper bus bar chamber of suitable rating, with and including separate MCB chambers suitable for acommodating 04 (Four) Nos. of 10 Amps MCB SP 'C' curve and 01 (One) No. of MCB SPN 40 Amps 'C' curve, including cable glands terminals, hardware mounting arrangement including necessary welding, cutting and drilling work for the DBs to be fixed on channel of the frame with necessar nut, bolt and washers with channel/ plate of suitable size etc, complete all as specified and directed.Note : Rate is inclusive of all spare part and MCB. |
| 21 | Material & Labour for point wiring for one light point/ Ex-Fan point controlled by one flame proof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including stove enamelled steel ERW conduit 25 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete all as specified and directed by Engr-in-Charge. |
| 22 | S & F flame proof Switch rotary type with termination box in LM6, 16A single pole 230 V complete all as specified and directed nuy Engr-in-Charge. |
| 23 | Supply and fixing LED light fitting 1x20 Watt flameproof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protectionwith die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and directed by Engr-in-Charge. |
| 24 | Supply and fixing of flame proof Aluminum exhaust fan 300 mm sweep RPM 1400 with copper winding wire and fitting including making hole in the wall as directed by Engineer in Charge |
| 25 | M&L for earthing complete with galvanised iron plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50Mtrs below ground level) connected to GI EARTH STRIP 32x6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified including 40 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, PCC chamber using PCC(1:3:6) type C-1 using 20mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results (in white) on a black painted M.S. Plate (size 300x300x3mm th) duly welded with angle iron of size 40X40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.Note :- (i) GI earth strip and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) The rates quoted by the contractor are deemed to be included for MS sheet of size 300x300x3mm th, fixed with necessary nuts and bolts on angle iron of size 40X40x5mm, 60cm long and grouted with PCC block of size 200x200x250mm(PCC 1:3:6 using 20mm grade stone aggregate including necessary earth work for marking the result and purpose. |
| 26 | M & L for Cutting existing CI/GI pipe line 150 mm dia for insertion of tee of size 150 x 150 x 50 mm for branch connection including excavation and earth work complete |
| 27 | M & L for construction of brick masonry valve pits with sub-class B brick built in cement mortar (1 : 6) of size 600 x 600 x600 mm (internal dimension) with one brick walling and 750 mm x 750 mm x 100 mm base foundation with PCC (1 : 3 : 6) rendering cement plastering 10 mm thick with cement mortar (1 :4) on internal & exposed surfaces including MS cover of size 75 x 75 cm made out from 3 mm thick MS sheet including MS cover of size 75 x 75 cm made out from 3 mm thick MS sheet including 30 x 30 x 5 mm angle iron framing on MS cover as well as on top wall of the valve pit & painting of the MS cover with two coat of synthetic enamel paint over a coat of red oxide primer including necessary earth work all as specified and directed |
| 28 | Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed. |
| 29 | Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item |
| 30 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed |
| 31 | Supply, installation, testing and commissioning of 11kv, 3 Phase, 50Hz, totally enclosed metal glad SF-6 switch gear having rupturing capacity 350MVA of rating 630 Amp, extensible outdoor duty (IP 55 enclosure) SF6 gas insulated 4 Way motor operated Ring Main Unit comprising of 2 nos.630 AmpsVacuum Circuit Breaker as incomer for Commercial Supply (11Kv UPPCLSupply) and DG 11 Kv Supply and 2 nos. 630 Amps Vacuum Circuit Breaker as outgoing , cable termination from the front, breaking capacity 21KA/3sec (Internal Arc Classification AFLR 21kA-1sec with Bottom Exhaust both for tank and cable box as per IEC 62271-200), enclosed in robotically welded stainless steel tank having IP67 Degree of Protection, leak rate of SF6 gas less than 0.1% and tested as per IEC 60056/60694/60298. Protection CTs shall be ring core type, complete all as specified and directed. The outer enclosure shall have IP 55 protection,it should be Top Opening Canopy type, Indoor RMU placed inside Outdoor Enclosure should not be acceptable. Both the Load break switch and Breaker should have line side earth switch both incomer should be electrically & mechanically interlock. |
| 32 | (A) NOTE:- Other details:- System Particulars: (i) Nominal System Voltage : 11kV. (ii) Voltage variation on supply side : ±10 %. (iii) Corresponding Highest System Voltage: 12kV. (iv) Frequency : 50 Hz with ± 3 % tolerance.(v) Number of Phase : 3 Phases. (vi) Neutral earthling : Solidly earthed. (vii) Fault level (minimum) kA /Sec : 21/3). (viii) Lightning Impulse Withstand Voltage (kVp) : 75 (ix) One minute dry/wet power frequency withstand voltage primary (kV rms) : 28KV (x) Rated Dynamic Withstand Current (kAp) : 52.5KA. (xi) Number of Short Circuit Operations at rated short circuit current of 21 kA for Breaker - 50 Nos. (xii) Earth switch should have 5 closing operation at short circuit current (making operations E2 class) independent of breaker. Earth switch manual closing shall be driven by a fast acting / snap action mechanism, independent of operator and VCB action. (xiii) Side and rear cable entry is not acceptable, all operation, interlock, cable terminations and door shall be front side only. |
| 33 | (B) Applicable Standards for this RMU scope of work - IEC 62271-200. (i) The Ring Main Units shall confirm to the latest applicable, IEC 62271-100, IEC 62271-200. (ii) All live parts, bus bars, shall preferably be enclosed in non- magnetic and non-ferrite grade stainless steel tank Grade SS441 of minimum 2 mm thickness. The RMU shall be type tested for internal arc test of 21KA/1 sec AFLR with Bottom Exhaust for Safety of Personnel for both Tank as well as Cable Compartment as per IEC62271-200. The outer closure shall have IP 55 protection for complete switchgears, however it should be Top Opening Canopy & Indoor RMU placed inside Outdoor Enclosure should not be acceptable. The protection relay shall be for 3 O/C + 1E/F (IDMT Type) Self powered numerical protection relay with low and high set of over current and earth fault , MODBUS communication along with RS 485 Port / USB Port. (iii) Internal Arc Classification should be with Bottom exhaust only. RMUs should be manufactured, inspected, and invoiced from the OEM factory. (iv) Wireless Temperature & climatic sensor should be provided, Thermal Sensors to be mounted in Cable chamber on each function on cable termination and one number of wireless climatic sensor to be mounted on RMU at suitable location to monitor temperature and humidity data on HMI though PLC. (v) 1 set of surge arrester fix in outgoing way. (vi) VCB, Numerical Relay, HMI, FRTU and Thermal / climatic sensor should be of same make for better functioning, maintenance, and coordination. CA NO. CE(AF)/PRZ/GKP/07 of 2026-27 Sl Page No 37 SCHEDULE ‘A’ PART- I(BUILDING WORK) Srl No Description of items of works Drg No Unit No of units Rate in Rs Amount In Rs |
| 34 | (B) Applicable Standards for this RMU scope of work - IEC 62271-200. (i) The Ring Main Units shall confirm to the latest applicable, IEC 62271-100, IEC 62271-200. (ii) All live parts, bus bars, shall preferably be enclosed in non- magnetic and non-ferrite grade stainless steel tank Grade SS441 of minimum 2 mm thickness. The RMU shall be type tested for internal arc test of 21KA/1 sec AFLR with Bottom Exhaust for Safety of Personnel for both Tank as well as Cable Compartment as per IEC62271-200. The outer closure shall have IP 55 protection for complete switchgears, however it should be Top Opening Canopy & Indoor RMU placed inside Outdoor Enclosure should not be acceptable. The protection relay shall be for 3 O/C + 1E/F (IDMT Type) Self powered numerical protection relay with low and high set of over current and earth fault , MODBUS communication along with RS 485 Port / USB Port. (iii) Internal Arc Classification should be with Bottom exhaust only. RMUs should be manufactured, inspected, and invoiced from the OEM factory. (iv) Wireless Temperature & climatic sensor should be provided, Thermal Sensors to be mounted in Cable chamber on each function on cable termination and one number of wireless climatic sensor to be mounted on RMU at suitable location to monitor temperature and humidity data on HMI though PLC. (v) 1 set of surge arrester fix in outgoing way. (vi) VCB, Numerical Relay, HMI, FRTU and Thermal / climatic sensor should be of same make for better functioning, maintenance, and coordination. CA NO. CE(AF)/PRZ/GKP/07 of 2026-27 Sl Page No 37 SCHEDULE ‘A’ PART- I(BUILDING WORK) Srl No Description of items of works Drg No Unit No of units Rate in Rs Amount In Rs |
| 35 | Construction of CCR building, complete all as specified and all as shown in drawings. |
| 36 | Construction of FOL store building, complete all as specified and all as shown in drawings. Total amount of Schedule ‘A’ Part-I carried over to BOQ Rs 4280000.0 Signature of Contractor AAD (Contracts)For Accepting Officer SCHEDULE ‘A’ PART- II(INTERNAL WATER SUPPLY) Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 37 | S & F galvanised steel water tubes 15mm bore medium grade with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 38 | S & F galvanised steel water tubes 20 mm bore medium grade with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 39 | S & F Gun metal gate valves with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed. |
| 40 | S & F pillar taps 15mm bore , cast copper alloy fancy type with capstan heads, chromium plated, quarter turn, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 41 | S & F bib taps 15mm bore chromium plated, cast copper alloy, fancy type, quarter turn, with cup concealed type long shank, with capstan head screwed down, screwed for iron pipe or brass ferrule complete fixed to CPVC/ GI pipes including all necessary fittings all as specified and directed. |
| 42 | S & F angle cock 15mm bore , cast copper alloy fancy type, chromium plated, screwed down high pressure, with with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for iron pipe or brass ferrule complete including all necessary fittings complete all as specified and directed. |
| 43 | S&F CP Health faucet (ABS Body) stainless steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified Total amount of Schedule ‘A’ Part-II carried over to BOQ Rs 22107.22 Signature of Contractor AAD (Contracts)For Accepting Officer SCHEDULE ‘A’ PART- IIIINTERNAL ELECTRIFICATION Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 44 | Material and labour for point wiring with two single core 1.5 sqmm FRLS cable (nominal area) stranded copper conductor, PVC insulated unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia with modular metal flush box (suitable size and thickness) and modular white cover plate with frame of suitable module and wiring to be terminated in pressed steel sunken boxes including all accessories and using single core 1.5 Sqmm (nominal area) stranded copper conductor, PVC insulated unsheathed cable as in earth wire (green colour) connected to common earth dolly complete all as specified and directed for following :- |
| 45 | (a) One light, fan, bell point controlled by one switch. |
| 46 | (b) One 3 pin switch socket outlet point 5 Amps on independent board. |
| 47 | All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size. |
| 48 | M&L for Modular switch 1 way 6A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge. |
| 49 | M&L for Modular socket outlet 2/3 pin combined 2 module, 6 Amps, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge. |
| 50 | M&L for Modular socket outlet 2 in 1, 6 pins 6A and 16A, combined 2 module, complete all as specified and directed by Engineer in charge. |
| 51 | M&L for Modular switch 1 way 16A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge. |
| 52 | S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete all as specified and directed. |
| 53 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 54 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 55 | Supply & fixing MCCB DB VTPN 4 way with metal recessed double door, IP-43 protection suitable for MCCB as incommer and MCB as out going , VTPN DB's 415 Volt 3 Phase complete with appropriate size copper bus bar and neutral link of and including cutting chases to wall for fixing of DB and making good disturbed wall/surface all as required at site i.e directed by Engr-In-Charge. Note: MCCB 100 Amps shall be measured and paid seperately. |
| 56 | Supply and fixing factory made epoxy powder coated distribution board SPN 4 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed. |
| 57 | Supply and fixing MCB single pole 240 volt C curve 10 KA 5 to 32 Amps capacity all as specified and directed incl taking down old one. |
| 58 | Supply and fixing MCB single pole & neutral 240 volt 'C' curve 10 KA 40 to 63 Amps complete all as specified and directed incl taking down old one. |
| 59 | Supply and fixing MCCB, 415 Volt C curve 16 KA, 100 Amps capacity complete all as specified and directed incl taking down old one. |
| 60 | M&L Sub main wiring complete with 4 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V, FRLS grade with multistranded copper conductor ISI marked drawn through PVC rigid conduit and accessories fixed on surface/wall celing etc including provision of 1 run of 6 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity. |
| 61 | M&L Sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated unsheathed cable 1100V, FRLS grade with multistranded copper conductor ISI marked drawn through PVC rigid conduit and accessories fixed on surface/wall celing etc including provision of 1 run of 4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity. |
| 62 | M&L Sub main wiring complete with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed cable 1100V, FRLS grade with multistranded copper conductor ISI marked drawn through PVC rigid conduit and accessories fixed on surface/wall celing etc including provision of 1 run of 2.5 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity. |
| 63 | Supply and fix exhaust fan made of steel body complete with louvers shutters , 300 mm sweep, 900 RPM single phase, 230 Volts AC, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing and including writing MES No complete all as specified and directed. |
| 64 | Supply and fix ceiling fan 1200 mm sweep,BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor , class of insulation :B 3 Nos blade, 30 cm long down rod, 2 Nos, canopies, shackle kit, safety rope, copper winding , power factor not less than 0.9, service value (CMM/W0 minimum 6.00 Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374-2019), THD not less than 10 %, elctronic regulator unit for speed control and all remaining accessories including safety pin, nut, bolts and washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including wiriting MES No all as specified and directed. Total amount of Schedule ‘A’ Part-III carried over to BOQ Rs 344463.8 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- IVEXTERNAL WATER SUPPLY Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 65 | Supply & Fixing of 25 mm bore galvanized steel tubing , medium grade with all fittings and fixed to walls , ceilings or laid in floors, trenches complete as per IS 1239 Part-II all as specified and directed |
| 66 | Supply & Fixing of 50 mm bore galvanized steel tubing , medium grade with all fittings and fixed to walls , ceilings or laid in floors, trenches complete as per IS 1239 Part-II all as specified and directed |
| 67 | Supply and Fix Gun-metal, globe or gate valves, 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed |
| 68 | Supply and Fix Gun-metal, globe or gate valves, 50 mm dia with iron wheel head, screwed both ends for iron pipe and fixed Total amount of Schedule ‘A’ Part-IV carried over to BOQ Rs 60501.28 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VEXTERNAL ELECTRIC SUPPLY Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 69 | M&L for Sand cushioning/covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed.Note :- Punned thickness will be measured at the time of measurement and payment. |
| 70 | Supply and laying un-reinforced precast concrete cable cover, class HV, Type I, flat size 300 mm x 180 mm x 40 mm laid dry for protection of UG cable complete all as specified and directed |
| 71 | Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 400 Sqmm 3.5 core all as specified and directed |
| 72 | Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core all as specified and directed |
| 73 | BLANK |
| 74 | Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 35 Sqmm 3.5 core all as specified and directed |
| 75 | Supply and lay in trenches or passing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm 3 core all as specified and directed |
| 76 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed |
| 77 | S&F of 80 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified . |
| 78 | S&F of 100 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified . |
| 79 | M&L of indoor end terminal joints cold shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 95 Sqmm 3 Core all as specified and directed. |
| 80 | M&L of straight through joints cold shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 95 Sqmm 3 Core all as specified and directed. |
| 81 | S&F air termination multi point aluminium rod 12 mm dia and 300mm long fixed on PCC post 0.25x0.25m alongwith 1 mtr 40mm GI pipe med grade complete all as specified and directed. |
| 82 | S & F Aluminium strip 32x6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified. Total amount of Schedule ‘A’ Part-V carried over to BOQ Rs 7399491.0 Signature of Contractor AAD (Contracts) For Accepting Officer CA No CE (AF)/PRZ/GKP/07 of 2026-27 Sl Page No 44 SCHEDULE ‘A’ PART- VISEWAGE DISPOSAL Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs 1.0 2.0 3.0 5.0 6.0 1.0 M&L for PCC 1:3:6 type C-2 (using 20mm graded stone aggregate ) in concrete bed to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore. RM 20.0 466.89 9337.8 2.0 M & L for 150 mm bore reinforced concrete pipes, class NP 2 with one collar per length of pipe, complete all as specified. RM 22.0 364.0 8008.0 Total amount of Schedule ‘A’ Part-VI carried over to BOQ Rs 17345.8 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VIIBOUNDRY WALL, FENCING AND GATE Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 83 | M&L for PCC type B-2 1:2:4(40mm graded agg) as in foundation complete all as specified and directed. |
| 84 | S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 85 | Supply only chain link MS galvanised fencing, any size or type of minimum dia 3.15 mm or above as directed |
| 86 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standard rails, straining bolts etc. |
| 87 | M&L for mild steel round bar 10 to 12mm dia confirming Fe-410-W (Gde.E-250) Fe 290 (Gde - E-165) as in stiffeners to chain link fencing etc all as specified and directed. |
| 88 | M&L for Mild steel screw bolts with neck dia 11-15mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long |
| 89 | M&L for two coat synthetic enamel paint over a coat of red oxide primer on new steel surface of any description over 10cm width or girth including preparation complete all as specified |
| 90 | M&L for PCC type B-2 1:3:6(40mm graded agg) as in foundation complete all as specified and directed. |
| 91 | M&L Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing in repairs to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. as directed (each line of wire to be measured). Total amount of Schedule ‘A’ Part-VII carried over to BOQ Rs 185830.28 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VIIIAIR CONDITIONING AND REFRIGERATION WORK Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 92 | Supply, installation, testing and commissioning of Split type Air Conditioner of Capacity 1.5 TR, Inverter type,Indoor unit with copper coiling coil and outdoor unit with copper tube condenser coil complete with cordless remote control, filled with the latest environment friendly refrigerant R-32 fitted with highly energy efficient rotary compressor of copper wound, including PVC FRLS grade multistranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, Copper connection pipes with insulation, GI brackets/stand for outdoor unit, clamps, nuts, bolts,washers, drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with PCC, white cement and painting work to match with the existing surface of wall complete all as specified and directed. Note :- (a) Installation work to be carried out by (OEM or Authorised dealer).(b) Copper connection pipes with insulation exceeding 3 Mtrs and PVCdrain pipes shall be measured and paid in this account only.(c) Compressor Warranty 5 years. |
| 93 | Supply and fixing 20 mm bore Low density polyethylene (LDPE) drain pipe of pressure rating 6 kgf/sqcm for Split AC complete all as specified and directed. |
| 94 | S&F sheet metal enclosure with metal clad socket and earth plug with one number MCB 20/32 Amp including connecting complete all as specified (Make: Havells/HPL/Legrand ). Total amount of Schedule ‘A’ Part-X carried over to BOQ Rs 153562.44 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- IXEARTH WORK Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 95 | Excavating in soft loose soil for post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm |
| 96 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil. |
| 97 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 98 | Removal of excavated material not exceeding 50 mtr and deposintg where directed at a level n.exceeding 1.5 m above the starting point complete all as specified and directed. Total amount of Schedule ‘A’ Part-X carried over to BOQ Rs 549812.14 Signature of Contractor AAD (Contracts) For Accepting Officer Please Enable Macros to View BoQ information |