| 1 | Excavation in post holes (or similar holes) each n.exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth aroud in layers not exceeding 25 cm with soft/loose soil complete all as specified and directed by Engineer-in-Charge |
| 2 | M & L for hardcore of guage exc 63 mm but n.exc 100 mm deposited spread and levelled in layers n.exc 15 cm thick watered and rolled/rammed to a true surface with broken bricks complete all as specified and directed by Engineer-in-Charge |
| 3 | M & L for cement concrete in foundation filling, subbase and mass concrete type C2 1:3:6 (40 mm graded aggregate) complete all as specified and directed by Engineer-in-Charge |
| 4 | M & L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6 m mean radius in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge |
| 5 | M&L for Rendering 15 mm thick cement plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of wall and to be finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge |
| 6 | M&L for Rendering 15 mm thick cement plaster in cement mortar (1:4) on other than fair faces of brick work and surfaces to be finished even and smooth without using extra cement all as specified.(incl all necessary scaffolding, lifting arrangement) complete all as specified and directed by Engineer-in-Charge |
| 7 | M&L two coats of cement based paint on newly plastered surface including preparation complete all as specified and directed by Engineer-in-Charge |
| 8 | M&L for two coats of oil bound distemper of wall to newly plastered surfaces including preparation of surfaces complete all as specified and directed by Engineer-in-Charge |
| 9 | S&F Pre -painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge |
| 10 | S&F Pre -painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge |
| 11 | S&F for structural steel works of Fe 410W (Gde E 250) quality A, as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. including painted one shop coat of zinc chromate/red oxide primer paint (including preparation of surface) before fabrication complete all as specified and directed by Engineer-in-Charge |
| 12 | Painting to steel surfaces of any description over 10 cm in width or girth not otherwise described for two coat of synthetic enamel paint over a coat of red oxide, zine chrome complete all as specified and directed by Engineer-in-Charge |
| 13 | M&L for PCC 1:2:4 type B1 using (20 mm graded aggregate) as in blocks for hold fasts, benching, coping apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-ChargeNote : From work required for these item included in the unit rate of this item. |
| 14 | M&L 75 mm thick PCC type C2 1:3:6 (40mm graded aggregate) as in Plinth protection filled with mastic filling and 10 mm wide joints between the walls and plinth protection shall be filled with mastic filling complete all as specified and directed by Engineer-in-Charge |
| 15 | M&L for 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded aggregate) for sub base in flooring complete all as specified and directed by Engineer-in-Charge |
| 16 | M&L for 25 mm thick PCC 1:2:4 type B-1 (using 20mm graded aggregate) for subbase flooring complete all as specified and directed by Engineer-in-Charge |
| 17 | M&L for machine cut kota stone slab flooring 20-25 mm thick laid over and including cement screed base 15 mm thick in cement mortar 1:6, including cutting as required, rubbing and polishing to granite finish over complete all as specified and directed by Engineer-in-Charge |
| 18 | M&L for machine cut kota stone slab 20-25 mm thick as in riser of steps, skirting, dado and pillar laid over and including rendering of 10 mm thick in cement morter 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting as required, rubbing and polishing to granite finish complete all as specified and directed by Engineer-in-Charge |
| 19 | M&L for precast chequered tiles (factory made rectified) of size tiles 300mX300mmX25mm over 20mm thick cement screed layer in cement mortar 1:4 ,top layer glazed made in grey cement and pigment in required patterns(compressive strength not less than 250 kg per Sqm) as approved by complete all as specified and directed by Engineer-in-Charge |
| 20 | M&L for point wiring with and incl 1.5 sqmm (nominal area) PVC insulated multistranded copper conductor FRLS in PVC caping casing with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal ,One light point/fan point controlled by one way switch complete all as specified and directed by Engineer-in-Charge. Make of cable for wiring - Havells/Polycab/Anchor. |
| 21 | All as per the description of serial item No 1 here in before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engineer-in-Charge |
| 22 | All as per the description of serial item No 1 here in before but for one 3 pin socket outlet 15 Amp independent board with cable of size 2.5 Sqmm with 1.5 sqmm copper conductor in green colour for earth continuity conductor, complete all as specified and directed by Engineer-in-Charge |
| 23 | S&F for switch piano flush type 5/6 Amp single pole one way, all as specified and directed by Engr-in-charge. |
| 24 | Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings all as specified and directed by Engr-in-charge. |
| 25 | M&L Ceiling rose surface bakelit 65x50mm three terminals complete and making necessary connections all as specified and directed by Engr-in-charge. |
| 26 | S&F MCB DB 4- Way, single door, 240 volts for Sheet Steel, Phosphatised, Powder Painted MCB DBs with Bus Bar,Neutral Link, Earth Bar and Din Rail (In accordance with IS 13032, IS 8623, IEC/BSEN 60439-3) and all as specified and directed by Engr-in-charge. |
| 27 | S&F MCB SP 6-32 Amps 'B' series 240V 50Hz 10 KA suitable for lighting and other domestic loads complete including taking down all as specified and directed by Engr-in-charge. |
| 28 | Supply & fixing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminiuum solid conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire one Twin core 10 sqmm solid conductor all as specified and directed by Engr-in-Charge. |
| 29 | S&F energy saving 10 Watt LED IP 65 Bulk head luminaries, complete with all accessories, internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size 230V,50 HZ all as specified and directed by Engr-in-charge. |
| 30 | Supply and fx Socket outlet 2 in 1, 3 pin, 6A all as specified and directed by Engr-in-charge. |
| 31 | Supply and fixing SPN 32 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 32 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified and directed by Engr-in-charge or indicated including testing on completion |
| 33 | Supply and fx Socket outlet 2 in 1, 3 pin, 6A all as specified and directed by Engr-in-charge. |
| 34 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |