| 1 | Surface excavation not exc 30cm deep and averaging more than 15cm deep and getting out in soft/loose soil, complete all as specified and directed. |
| 2 | Excavation in trenches not exc 1.5 m deep and nexc 1.5 m width in soft/loose soil, complete all as specified and directed. |
| 3 | M&L PCC Type D-2, 1:4:8 using 40 mm aggregate as in foundation, complete all as specified and directed. |
| 4 | Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 5 | Returning filling in with approved excavated soil including spreading, levelling in layers not exc 25cm thick, complete all as specified and directed. |
| 6 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed. |
| 7 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed. |
| 8 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. |
| 9 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 10 | All as per item No 09 herein before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed. |
| 11 | M&L for RCC design mix M-25 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 12 | M&L for RCC design mix M-25 (20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 13 | M&L for RCC design mix M-25 (using 20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed. |
| 14 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6, complete all as specified and directed. |
| 15 | Rendering 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surface finished fair and even complete all as specified and directed. |
| 16 | M&L two coats of cement base paint over a coat of white wash on newly plastered surface on wall including preparation of surface, complete all as specified and directed. |
| 17 | S&F rolled mild steel in Plate girder or single stanchions, built up of one beam or channel section with flange plates,caps,bases, splices, angle brackets,cleats, Nut and bolt and other connection for column and strut etc conforming to Fe-410 Gde E-250 quality A, complete all as specified and directed. |
| 18 | S&F mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel, hollow or flat sections) including distance pieces, cleats etc. conforming to Fe-410 Gde E-250 quality A, complete all as specified and directed. |
| 19 | M&L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 20 | S&F Pre-painted galvalume aluminium zinc coting GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws ,complete all as specified and directed |
| 21 | S&F Pre-painted galvalume aluminium zinc coting GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws ,complete all as specified and directed |
| 22 | M&L for Hardcore of broken stone or boulder of gauge nexc 63mm, deposited, spread and levelled in layers nexc 15cm thick, watered and rammed to a true surface, complete all as specified and directed |
| 23 | M&L for cement concrete 1:2:4 type B1 using 20 mm graded aggregate as in levelling course with smooth finish, complete all as specified and directed. |
| 24 | M&L for 25mm thick sand filling under floors including watering and consolidation, complete all as specified and directed. |
| 25 | M&L 80mm thick M-40 grade machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 with grey cement and pigment, complete all as specified and directed. |
| 26 | M&L for laying or near ground level factory made Kerbstone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 including making joints with or without grooves including making drainage opening whereever required, complete all as specified and directed. |
| 27 | M&L machine cut kotstone slab flooring 16-18 mm thick over 20mm thick CM (1:4) screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 28 | M&L machine cut kotastone slab 14-16 mm thick in riser of steps, skirting dado and pillar laid over 15mm thick CM (1:4) screed bed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 29 | Excavation over areas not exc 1.50m deep and getting out any type of soil, complete all as specified and directed. |
| 30 | M&L for spreading and levelling in layers not exc 25cm thick well ramming , watering, complete all as specified and directed |
| 31 | Rolling and consolidating formation surfaces of road in cutting with 8 to 12 tonne power roller, complete to required level, gradient slope, camber, super elevation including filling depression and including approved earth which may occur during rolling process, complete all as specified and directed. |
| 32 | M&L for 150mm thick GSB grade II as per MORTH specification,surface formed,water and rammed, rolled and consolidated to required camber and gradient by using earth compactor complete all as specified and directed. |
| 33 | M&L for Laying and compaction of 150mm thick compacted thickness in two layer (75mm each) Wet Mix Macadam (WMM) grading as per table 400-13 of MoRTH Specifications for road and bridge works 2013 manufactued in WMM Plant, material comprising of clean, crushed, graded aggregate andgranular material premixed with water to a dense mass, spreading wit sensor paverand rolling with vibratory roller of capacity 80-100 KN static weight and consolidating to required gradient and camber, complete all as specified and directed. The finished surface tolerance to be as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013 complete all as specified and directed. |
| 34 | Providing and laying 100mm thick dry lean concrete (DLC) of compressive strength not less than 10Mpa at 7 days for each consecutive group of 5 cube or individual strength of cube shall not be less than 7.5Mpa at 7 days using table 600-1 for grading of aggregate minimum cement content shall not be less than 150Kg/cum as per MORTH specifcation incl spreading and compacted by using mechanical vibratory roller of capacity 8 to 12 tonne complete all as specified and directed. |
| 35 | M&L for 400 micron polythene film black laid over sand layer with side and end overlappings shall not be less than 300mm complete all as specified and directed. |
| 36 | M&L for PQC of flexural strength 45kg/sqcm in field using minimum 400kg of cement per cubic meter (with maximum size of coarse aggregate upto 40mm) thickness of concrete 100mm including formwork for laying in bays and mixing of non-circular synthetic fibre and admixture as per manufacturer's instructions complete all as specified and directed.Note :- non-circular synthetic fibre and admixture shall be measured and paid seperately. |
| 37 | Providing Broom finished surface of concrete pavement while concrete is green, complete all as specified and directed. |
| 38 | Supply only non-circular synthetic fibres with circumcircular dia 30-35 micron, designed for melting point of 240-260 degree celsius and having specific gravity of 1.34 to 1.40, Recron 3S for mixing the it in PQC as per manufacturers instructions, complete all as specified and directed. |
| 39 | Supply only admixture complast SP-430-A-1 including plant and labour for mixing the admixture in PQC as per manufacturers instructions complete all as specified and directed. |
| 40 | Forming construction joint 25mm deep and 10mm wide using diamond cutter and sealed with polyurethane sealant colplises with BS:5212 and priming the sides provision of closed cell polyethylene backup rod 12mm dia applying tape in false complete all as specified and directed. |
| 41 | M&L for forming 25mm thick expansion joint filled with DURA board HD100 (band supreme or equvialent) apply bond breaker tape on tape on top of board for complete filled with polyurethene sealant above backup rod shall be 12mm complies with BS:5212 and priming the sides and makiing tape on ealse of point to prevent concrete slab 300mm complete all as specified and directed. |
| 42 | Forming construction/Dummy joint 85mm deep x 10mm wide and filled with extanded polyurethane foam (Armoury Board) applying bond backup tape of Armour board for complete with of joint provision of closed cell polybackup rod 12mm dia sealed with 10mm (depth minimum above backup rod) complete all as specified and directed. |
| 43 | Supply and installation wall mounted heavy duty air circulator fans industrial type 600 mm sweep, 240V, automatic rotation, air delivery not less than 245 cub mtr/min, 1440 RPM including making neccesary connection with suitable size copper wire complete all as specified and directed. |
| 44 | Supply and fixing LED tubelight fitting 1x 20W, 220V, AC with driver, holder, aluminium housing, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 45 | Supply and fixing LED bldg light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 46 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 47 | M&L for point wiring light/fan point with PVC insulated FRLS unsheathed single core cable of multistranded copper conductor of size 1.5 sqmm as phase & neutral drawn in and including PVC conduit medium grade not less than 20 mm dia, ISI marked, duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated FRLS unsheathed copper conductor(Green in color) as earth wire and connected to common earth dolly incl provn of electrogalvanised steel terminal switch box and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing switches/ socket/ regulators etc. complete all as specified and directed. |
| 48 | All as per item No 47 above but for One 6 pin 15/16 amps socket outlet on independent board with cables of size 2.5 sqmm |
| 49 | S&F switch Piano Flush button single pole one way 5 Amp complete all as specified and directed. |
| 50 | S&F switch piano flush single pole one way 15/16 Amps complete all as specified and directed. |
| 51 | S&F socket outlet flush type 5/6 pin 15 Amps 230V AC complete all as specified and directed. |
| 52 | S&F ceiling rose PVC polycarbonate 3 copper terminals complete all as specified and directed. |
| 53 | M&L for Sub main wiring with two single core PVC insulated unsheathed, grade cable 2.5 sq.mm (nominal area) FRLS type multi stranded copper conductor and one run of 2.5 sq.mm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS including provision of cutting chases for conduit and sinking for boxes and laying through and including provision of 20mm dia 'medium grade' PVC conduit and fittings, complete all as specified and directed.NOTE:- (i) Two runs of 2.5 sq.mm copper conductor, one run of 2.5 sq.mm copper earth continuity conductor and one run of PVC conduit and its fittings shall be measured as one unit length.(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. |
| 54 | S&F MCB DB SPN 4 way with 200 amps 240 volts rated busbar in sheet steel enclosure.double door type complete all as specified & directed. |
| 55 | S&F MCB DB SPN 8 way with 200 amps 240 volts rated busbar in sheet steel enclosure.double door type complete all as specified & directed. |
| 56 | Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 57 | Supply & fixing MCB, SPN, AC, 240 volts of 40 Amps to 63 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 58 | Supply, laying, testing XLPE cable Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core incl earth work complete all as specified and directed. |
| 59 | M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below NGL and top edge of the plate not less than 1.5 Mtr deep below NGL, surrounded with adequate qty of char coal dust mixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate incl excavation, earth work, returning filling in , removal of surplus soil to a distance in n.exc. 50 mtr incl GI wire 4mm dia nut bolts etc to earth plate one end connected to continuous earth wire incl GI pipe watering light grade with CI funnel and wire mesh and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both ways with 10mm dia MS bar lifting handles, all as described in electric plate No. 3 of SSR part-I complete all as specified and directed. Please Enable Macros to View BoQ information |