| 1 | Providing labour for deployment of team consistiing of one electrion(ITI qualified) and two helper and providing transport and T&P for locating the fault in HT/LT line in OH/UG Line/cable by visual inspection recce of faulty area and repairs to the fault by means of replacement of Unservicable Jumpers /Fuse wires / Burnt lugs/all type of insulator/ MCCB etc. inclusive restraining of broken/loose ACSR conductorss/Earth wire etc Making tamporary connection if required to make the countinity of supply , The Cable required shall be given by department from AGE E/M store for temporary resume the power supply.The area coming under Sub Station No. 01,02,05 & Map pocket-5 shall be covered under the subject work to maintain the countinity of supply complete all as directed by Engineer-in-chargeNote: (i) Materials requried for fault repairs will be measured under relevant items of this BOQ.(ii) Contractor will depute the dedicated team (one electician (ITI holder) and two helper)., Contractor will be responsible for the safety of his team deployed. No dispute regarding safety of person would be entertain later on. If any mishappening occures during rectifaction of fault in HT/LT lines contractor will be fully liable to bear all the expenses of staff deployed.(iii) Contractor will provide all set of T & P such as (a) HV (11000Volts) digital insulation tester (b) LV (1100V) digital insulation tester (c) Digital clamp meter up tp 1100 V and 1000Amps (d) Search light, rain coat (e) Cutting pliers (f) Screw Driver set, box spanner/wretched spanner (g) Allen key set (h) 11000V grade safety gloves, rubber boots, Safety belt and helmets, torch lights etc (i) Earthing rod (j) Bamboo ladder for desired height. (k) PVC tape roll (HV/LV) for routine maintenance and protection of the trademan incl safety equipment such as Hand gloves, Rubber boots, safety belt and helmets etc communication device (Mobile Phone) to deployed persons, Electrcian team (One Electrician (ITI Holder and Two Helper) as per site requirement. (iv) On intimation of any type of repair/maintenance work of HT/LT switch gear incomer as well as out going feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity /nature of the work involved to restore the power supply and communicate with SBA on duty and getting permit card for working on HT lines and deposit the permit card after rectification of fault, all the activities shall be carried out within reasonable time as given by the Engineer-in-Charge.(v) Contractor will provide necessary complaint slip, complaint boook & permit book, contractor will direct the instructions to indis for lodgging the complaints duly marked the location, time and date for earlier rectifications.(vi) After getting the complaints, team deployed by the contractor will rectify the complaints within stipulated time i.e within 2 hours from the time of receiving of complaints.(vii) Contractor should also provide a dedicated supervisor for collection of complaints from SBA, JE, USER etc. He would be held responsible, in case complaints are not collected |
| 2 | Material and labour for providing following stationary require to lodge the complaint, as per requirement and as per existing sample for a minimum period of 9 Months from the date of commencement of contract to sub stn No.1,2 5 and Map Pocket No.-5 complete all as directed by Engineer-in-charge:- (i) Complaint Register/books as per sample. (ii) Complaint Slip/job card as per sample.(iii) Permit book as per sample.(iii) Other materials ie glue stick,pen, pencil, carbon paper and stainless steel scale 1'. |
| 3 | Connecting /disconnecting connection of air-conditioner in married officers quarters, OTM, offrs Mess from the existing over head lines complete all specified and as directed by Engineer-in-charge. Note:-Cables and materials for connection will be provided by occupant /user of the accn |
| 4 | Supply only the HT fuse wire of 5 Amps capacity. |
| 5 | Supply only the HT fuse wire of 10 Amps capacity. |
| 6 | Supply only the HT fuse wire of 20 Amps capacity. |
| 7 | Supply only the HT fuse wire of 32 Amps capacity. |
| 8 | Supply only the HT fuse wire of 40 Amps capacity. |
| 9 | Supply only the HT fuse wire of 60 Amps capacity. |
| 10 | Supply only the HT fuse wire of 100 Amps capacity. |
| 11 | Material and labour for replacement of HT Disc insulator 11KV on single/two/four pole structure by dedicated team well known working on HT lines by using all means of safety gears/T&P after getting job card and permit slip of shut down all as specified and as directed by Engineer-in-charge.. |
| 12 | Material and labour for replacement of HT Pin insulator 11kV on single/two/four pole structure by dedicated team well known working on HT lines by using all means of safety gears/T&P after getting job card and permit slip of shut down all as specified and as directed by Engineer-in-charge.. |
| 13 | Material and labour for replacement of LT Pin insulator 1.1KV on LT pole height 9.0 M by dedicated team well known working on LT lines by using all means of safety gears/T&P after getting job card and permit slip of shut down all as specified and as directed by Engineer-in-charge. |
| 14 | Material and labour for replacement of multi-jointed ACSR jumpers of HT over head lines with and including XLPE/PVC insulated 11000 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red, yellow, blue and black for neutral including fixing with ACSR conductors with suitable size PG (Parellel Groove) clamp complete all as specified and directed. Note: Length of one jumper shall not exceeding more than 3.0 mtrs |
| 15 | Material and labour for replacement of multi-jointed ACSR jumpers of HT over head lines with and incl XLPE/PVC insulated 11000 volts multi stranded aluminium conductor single core cable of size 240 sqmm as per colour code in sequence Red, yellow, blue and black for neutral incl fixing with ACSR conductors with suitable size PG (Parellel Groove) clamp complete all as specified and directed. (Length of one jumper not exceeding more than 3.0 mtrs |
| 16 | Material and labour for replacement of multi-jointed ACSR jumpers of LT over head lines with and incl XLPE/PVC insulated 1100 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red, yellow, blue and black for neutral incl fixing with ACSR conductors with suitable size PG (Parellel Groove) clamp all as specified and as directed by Engineer-in-charge. Note: Length of one jumper not exceeding more than 3.0 m |
| 17 | Material and labour for replacement of multi-jointed ACSR jumpers of LT over head lines with and including XLPE/PVC insulated 1100 volts multi stranded aluminium conductor single core cable of size 240 sqmm as per colour code in sequence Red, yellow, blue and black for neutral incl fixing with ACSR conductors with suitable size PG (Parellel Groove) clamp complete all as specified and as directed by Engineer-in-charge. (Length of one jumper not exceeding more than 3.0 m |
| 18 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for e 10 sqmm cable including necessary crimping with crimping tool all as specified and as directed by Engineer-in-charge.. |
| 19 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for 16 sqmm cable including necessary crimping with crimping tool all as specified and as directed by Engineer-in-charge.. |
| 20 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for cable up to 25 sqmm including necessary crimping with crimping tool all as specified and as directed by Engineer-in-charge.. |
| 21 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for 35 sqmm cable including necessary crimping with crimping tool complete all as specified and as directed by Engineer-in-charge.. |
| 22 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for 50 sqmm cable including necessary crimping with crimping tool complete all as specified and as directed by Engineer-in-charge. |
| 23 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for 70 sqmm cable including necessary crimping with crimping tool complete all as specified and as directed by Engineer-in-charge.. |
| 24 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for 95 sqmm cable including necessary crimping with crimping tool complete all as specified and as directed by Engineer-in-charge.. |
| 25 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for 120 sqmm cable including necessary crimping with crimping tool complete all as specified and as directed by Engineer-in-charge.. |
| 26 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for 150 sqmm cable including necessary crimping with crimping tool complete all as specified and as directed by Engineer-in-charge.. |
| 27 | Supply and fix in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for 185 sqmm cable including necessary crimping with crimping tool complete all as specified and as directed by Engineer-in-charge.. |
| 28 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for sqmm including necessary crimping with crimping tool complete all as specified and as directed by Engineer-in-charge.. |
| 29 | Supply and fixing in replacement cable lugs aluminium heavy duty type working voltage 1100 Volts suitable for cable up to 300 sqmm including necessary crimping with crimping tool complete all as specified and as directed by Engineer-in-charge.. |
| 30 | Supply and fixing in replacement MCCB 4 pole 415 volt , AC 50 Hz with adjustable thermal and magentic release ( adjustable type) 63 Amp with breaking capacity 25 kA complete all as specified and as directed by Engineer-in-charge.. |
| 31 | Supply and fixing in replacement MCCB 4 pole 415 volt , AC 50 Hz with adjustable thermal and magentic release ( adjustable type) 100 Amp with breaking capacity 25 kA complete all as specified and as directed by Engineer-in-charge.. |
| 32 | Supply and fixing in replacement MCCB 4 pole 415 volt , AC 50 Hz with adjustable thermal and magentic release ( adjustable type) 160 Amp with breaking capacity 25 kA complete all as specified and as directed by Engineer-in-charge.. |
| 33 | Supply and fixing in replacement MCCB 4 pole 415 volt , AC 50 Hz with adjustable thermal and magentic release ( adjustable type) 200 Amp with breaking capacity 25 kA complete all as specified and as directed by Engineer-in-charge.. |
| 34 | Material and labour for replacement Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to Gl wire 4mm dia by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover, charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 15mm dia GI pipe light grade for projection of earth lead, wire mesh and connected to earth point complete all as shown in electric plate No 3 of SSR part -I 2009.including testing on completion complete all as specified and as directed by Engineer-in-charge. |
| 35 | Material and labour for replacement Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI strip 32 x 6mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover, charcoal & common salt. filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia Gl pipe light grade for protection of Gl strip, wire mesh and connected to earth point complete all as shown in electric plate No 3 of SSR part -I 2009.including testing on completion complete all as specified and as directed by Engineer-in-charge. |
| 36 | Material and labour for fixing, installation, commissioning and testing of switch Air break, Gang operated with 15 insulator switch Triple pole, mechanicaly operated, mounted on insulator and steel frame, for current rating 200 Amp operating Voltage 11 KV out door, vertical mounted type, complete with locking arrengement, assembly with fuse mount carrier and fuse element of required capacity and isolator suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity as required at site and directed by Engr-in-Charge, with DO fuses assembly and one number operating rod of 25 mm dia bore medium grade GI pipe of suitable length, worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD including nut, bolt, washers including taking down existing unservicable set complete all as specified and as directed by Engineer-in-charge. |
| 37 | Supply and fixing Lightening arrestor expulsion type conform to IS 3070 (part I) complete with all fittings transmission classes discharge Capacity 65 KA suitable for 11 KV out door type complete, including taking down the existing LA complete all as specified and as directed by Engineer-in-charge. |
| 38 | Supply and fixing in replacement MCCB 4 pole 415 volt , AC 50 Hz with adjustable thermal and magentic release ( adjustable type) 250 Amp with breaking capacity 25 kA complete all as specified and as directed by Engineer-in-charge.. |
| 39 | Supply and fixing in replacement MCCB 4 pole 415 volt , AC 50 Hz with adjustable thermal and magentic release ( adjustable type) 400 Amp with breaking capacity 25 kA complete all as specified and as directed by Engineer-in-charge.. |
| 40 | Supply and fixing in replacement of old U/S ACB Microprossessor relese based type 50H2. 4 Pole 600 Amp, 50 KA, with electronic protection unit with LSI/LSIg+NEUTRAL O/L+ OVER TEMPERATURE PROTECTION complete including taking down the u/s VCB complete all as specified and as directed by Engineer-in-charge.. |
| 41 | Supply and fixing ACB Microprossessor relese based type 50Hz, 4 Pole 800Amp 50 KA, with electronic protection unit with LSI/LSIg+NEUTRAL O/L+OVER TEMPERATURE PROTECTION complete including taking down the u/s VCB complete all as specified and as directed by Engineer-in-charge.. |
| 42 | Material and labour for Periodical cutting of trees/trimming of branches along the HT/LT overhead lines in a girth of 03 mtrs on either side of the conductors including removing the same and dumping out of MD land complete all as specified and as directed by Engineer-in-charge. Note:- The cost of tool and plants required for Periodical cutting of trees/trimming of branches along the HT /LT overhead lines are deemed to be included in rate quoted by the contractor. |
| 43 | Material and labour for cutting of grass, vegetation and bushes etc and surface dressing the area surrounding HT two pole / four pole structure, plinths, substations , at AGE E/M store yard and rubbish off the premises as directed complete all as specified and as directed by Engineer-in-charge. |
| 44 | Supply and fixing including commissioning factory made 16 M high mast light 360/150--3/3 shaft in two section suitable for 47 m/sec wind speed along with head frame, luminaires carriage suitable for 6-9 luminaires in symmetrical arrangement including the following:(i) Raising and lowering system comprising double drum winch,(ii) 4mm diameter SS wire rope,(iii) trailing cable, connector,(iv) integral power tool motor,(v) manual handle, junction box, lightning finial.(vi) Supply and fix foundation bolts along with nuts, washers, anchor plate and common template.(vii) Supply and fix LED type single dome aviation obstruction light.(viii) Supply and fix outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| 45 | Supply and fixing including commissioning factory made 16 M high mast light 360/150--3/3 shaft in two section suitable for 47 m/sec wind speed along with head frame, luminaires carriage suitable for 6-9 luminaires in symmetrical arrangement including the following:(i) Raising and lowering system comprising double drum winch,(ii) 4mm diameter SS wire rope,(iii) trailing cable, connector,(iv) integral power tool motor,(v) manual handle, junction box, lightning finial.(vi) Supply and fix foundation bolts along with nuts, washers, anchor plate and common template.(vii) Supply and fix LED type single dome aviation obstruction light.(viii) Supply and fix outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |