| 1 | Supply, installation , testing and commissioning Heavy duty plastic packaged Air cooling unit Evaporative type model No VC 20U and 11771 CFM at zero static , power consumption 1.1 KW along with cool flow dispenser for enhanced cooling and weather resistant and body material with UV stabilized Engineering Plastic Body for design powerful air delivery , 04 Side cooling pads for superior cooling and single phase motor and fan to deliver the powerful air flow for better cooling , auto connection of water tank to quick fill ,water connection with ball valve drain and overflow connection complete with to be must comprising as given below:-Tank Capacity -70 Ltrs , Cooling Media:- Honeycomb pads Pad Thickness:- 100mmAir moving device:- FanFan diameter:- 620 MMCooling Surface area of pads\\"- 1.6 SqmMinimum cooling efficiency:- 80%Discharge flow:- Top/Bottom ( as per site condition )Cooling Area:- 2000 SqftNominal Air delivery: - 20000 CMHController :- as per standard and OEM recommended |
| 2 | Supply, installation , testing and commissioning Heavy duty plastic packaged Air cooling unit Evaporative type model No VC 11U and 6400 CFM at zero static and power consumption 0.45 KW along with cool flow dispenser for enhanced cooling and weather resistant and body material with UV stabilized Engineering Plastic Body for design powerful air delivery , 03 Side cooling pads for superior cooling and single phase motor and fan to deliver the powerful air flow for better cooling , auto connection of water tank to quick fill ,water connection with ball valve drain and overflow connection complete with to be must comprising as given below:-Tank Capacity -50 Ltrs , Cooling Media:- Honeycomb pads Pad thickness:- 60 mm Air moving device:- FanFan diameter:- 425 MMCooling Surface area of pads\\"- 1.45 SqmMinimum cooling efficiency:- 80%Discharge flow:- Top/Bottom/Side ( as per site condition )Cooling Area:- 700 SqftNominal Air delivery: - 11000 CMHController :- as per standard and OEM recommended |
| 3 | Supply and fixing of Canvas cloth connection suitable size for air cooler complete all as specified and directed. |
| 4 | Supply and installation of GI, Pre fabricated rectangular GI ducts, of 24 SWG, Galvanised Iron Sheet thickness 0.70 mm complete with MS flanges and bracing (as specified), necessary supports using thread rods (as directed) and anchor bolts, supply air collars, vanes, splitters,any retrofit work complete with for suitable air flow incl cutting on wall and make a good to disturbed area as per existing complete all as specified and directed. |
| 5 | Supply, installation, double deflection ABS Grill as per suitable size \\" with powder coating with Damper including civil work with core cut, chiselling , cutting of wall , plaster etc and making good disturbed surfaces area after fitting the all respect all as specified and directed. |
| 6 | Supply , installation , testing and commissioning of Paramount/Nitrile rubber close cell flat insulation 09 mm thick on SA Duct on required sun expose area appllied on Newly installed Ducting line complete all as specified and directed. |
| 7 | Supplying, Laying ,and testing in of XLPE insulated armoured heavy duty electric cable of the size 25 Sqmm 4 core following size ,1100 Volts grade , with stranded aluminium conductor served with an inner sheathing of PVC tape armoured with GI wire and over all PVC sheathed in laid trenches/ passing through pipe/duct/road crossing/surface of wall/in hume pipe etc including fixing hardware,clamps,gland, thimble and making good the damaged surfaces etc complete all as specified and as directed. |
| 8 | Supply and Fixing in repair Sheet metal enclosers made out of CRCA mild steel sheet not less than 1.2mm thick,, IP-54 protection, flush mounted for metal door, powder coated double door VTPN 4 way, 415 V AC with 200 Amps rated copper bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCCB and outgoing MCBs / MCCBs/ Isolators and earth & neutral bus bar etc conforming to IS/IEC-61439-2:2011, BS-5484 , including flush to wall and existing surface to be matched complete all as specified and as directed by Engineer-in- charge.Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 9 | Supply and fixing in replacement of MCCB 100 Amp, 4 Pole, 415 volt, ISI Marked,short circuit breaking capacity not less than 25KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, thimbles, nuts, bolts, washers etc .complete all as specified and directed. |
| 10 | supply and fixing in replacement of sheet metal enclosure MCB board, 02 way, with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including DP MCB 16 Amp, 10 KA alongwith l cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. |
| 11 | supply and fixing in replacement of sheet metal enclosure MCB board, 04 way, with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including FP MCB 63 Amp 10KA alongwith l cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. |
| 12 | Supply and Fixing of metallic exhaust fan of sweep 300 mm along with metallic louver complete including cutting of wall, making of proper hole sufficient to fix exhaust fan and smoothing of the surface before fixing of exhaust all as specified and directed. |
| 13 | Material and labour sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to matched and finised with existing surface are included in the ratecomplete all as specified and directed.Make of cable - Polycab/Havells/Grandlay cable Note:- (i) 2 run of 6.0 Sqmm main cable, one run of 6.0 Sqmm earth wire and two run length of PVC conduit of size 25mm shall be considered as one running length.(ii) The wiring shall be done in proper color coding using Red,Yellow, Blue for phases, Black for neutral and Green for earth. |
| 14 | Material and labour sub main wiring with 06 Sq mm nominal cross sectional area, Four single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to matched and finised with existing surface are included in the ratecomplete all as specified and directed.Make of cable - Polycab/Havells/Grandlay cable Note:- (i) 4 run of 6.0 Sqmm main cable, one run of 6.0 Sqmm earth wire and two run length of PVC conduit of size 25mm shall be considered as one running length.(ii) The wiring shall be done in proper color coding using Red,Yellow, Blue for phases, Black for neutral and Green for earth. |
| 15 | M&L labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed. |
| 16 | M & L for Cutting existing steel tubing 25/32 mm for alterations or additions (Each cut measured) including screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector complete all as specified and directed. |
| 17 | Supply and fixing of 3 layer PVC water Tank capacity of 1000 Ltr incl ball brass valve high pressure ,with polythene float and flynut complete fiitting on existing roof complete all as specified and directed. |
| 18 | Supply laying in replacement of CPVC pipes size of 25 mm dia, SDR 11 & plain SDR -11 fitting fixed to wall/ceiling or in floor etc, including all fitting i.e bend, tee,coupler,flange,end cap etc complete all as specifed and as directed |
| 19 | Supply laying in replacement of CPVC pipes size of 16 mm dia, SDR 11 & plain SDR -11 fitting fixed to wall/ceiling or in floor etc, including all fitting i.e bend, tee,coupler,flange,end cap etc complete all as specifed and as directed |
| 20 | Supply and replacement of CPVC Ball Valve size of 25MM dia complete all as specified and as directed. |
| 21 | Supply and replacement of CPVC Long handle Ball Valve size of 15 MM dia complete all as specified and as directed. |
| 22 | Note:- 1. All kind of civil work ānd Cooler stand made angle MS angle iron frame work as per site requirement for installation of Air Ducting cooler and fixing/hanging of Air Duct will be included in the overall rate quoted by the firm.2. Work of Air duct cooler will be executed through specialized agency having minimum 03 year experience in this field. |
| 23 | Demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars etc., in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and directed. |
| 24 | Excavation in trenches in soft/Loose soil not exc 1.5m wide & not exc 1.5m deep for foundation of manholes,sewerage pipe lines, etc. & including getting out complete all as specified. |
| 25 | M&L cement concrete in foundation type D-2 1:4:8 (40 mm graded aggregate ) filling and mass concrete in manholes etc complete all as specified and directed. |
| 26 | M&L brick work with sub class 'B' brick old size burnt clay bricks, straight or curved on plan exc 6.0m mean radius built in cement mortor 1:6 complete all as specified. |
| 27 | M&L for cement concrete type B0 1:2:4mix (12.5 mm stone aggregate) as in coping / Bed block on brick wall (Channels/ drain wall)& similar work etc including necessary form work complete all as specified and directed |
| 28 | Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. |
| 29 | M & L for rough cast plastering including 15mm thick rendering in cement plaster 1:4 complete as specified and after applying under coat of cement mortar 1:3 not less than 20mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied complete including taking down cement lime plaster and applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 30 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 31 | Returning filling including spreading levelling watering and well ramming in layers n exc 25 cm in soft/loose soil, etc complete all as specified and as directed. |
| 32 | Removal of excavated material to a distance not. exceeding 50m & depositing where directed at level not exceeding 1.5m above the starting point complete all as specified and as directed . |
| 33 | M & L for complete remaoval of existing treatement (any layers of rxisting treatment) and efflorescence from old decorated surface of wall/pillars/cornices by scraping down with using Mechanical sander machine (inmcluding provision of dust sucking) upto entire satisfaction of engr-in-charge brooming down and preparing the surfaces smooth and make good by applying 2mm thick wall care putty with white cement based equvilent as approved by engr-in-charge and sanding the surface by Mechanical sander machine to make the surface even and smooth upto entire satisfaction of Engr-in-charge and after that applying two coat of plastic emulsion paint(with roller brush only) complete all as specified and as directed . |
| 34 | M & L for complete removal of existing treatment (any layers of existing treatment) effloressence from old decorated surface of wall/pillars/cornices by scraping down with using Mechanical sander machine (inmcluding provision of dust sucking) upto entire satisfaction of engr-in-charge brooming down and preparing the surfaces and after that applying two coat of acrylic smooth exterior emlusion paint as approved tint/colour by using paint roller brush only complete all as specified and as directed . |
| 35 | Excavating in post holes or similar holes each n.exc 0.50 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earth arround in layers n exc 25cm watering and ramming surplus soil to a distance e exc 50m and making good as in soft/loose soil complete all as specified and directed. |
| 36 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling, sub base and mass concrete complete all as specified and as direceted. |
| 37 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 38 | Refixing only roof trusses (Framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing ( Beam, tee, angle, channelor flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 39 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 40 | M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 roof trusses/ framing for roofing, purlins, grill/guard bars, gates etc, complete all as specified and directed |
| 41 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an green colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 42 | Fixing only Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an green colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 43 | M& L for preparation of steel surfaces over 10cm in width or girth and applying 02 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 44 | Surface excavation n.exc 30cm depth & average 15 cm deep & getting cut in soft/loose soil complete all as specified and as direceted. |
| 45 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. |
| 46 | M&L for rendering 15mm thick in cement mortar in 1:4 on Fair face of brick work or concrete surfaces even and fair without using extra cement complete all as specified and as directed |
| 47 | M & L applying Two coat of cement based paint on New plastered surface of wall over a coat of primer including preparation etc complete all as specified and directed. |
| 48 | Removing excavated material exc 1.50 Km but not exceeding 5 Km and depositing where directed |
| 49 | Supply only hard core broken to gauge exc 63mm and n exc 100 mm for filling of embankment. |
| 50 | M&L for 75mm thick PCC 1:4:8 type B-2 cement concrete in foundation, filling and mass concrete complete all as specified and as directed. |
| 51 | M&L for 25mm thick PCC 1:2:4 type B-0, (20mm graded aggregate) complete all as specified and as directed. |
| 52 | M&L for apoxy flooring 2mm (1+1) including surface preparation, grinding and cleaning surface area, cracks filling with the help of epoxy mortar there after application of apoxy primer Triflor EP 25 and application of self levelling under layer base coat Triflor SLUL 1mm thick and application of self Levelling top coat Triflor SL 1000 complete all as specified and as directed.Note:- Applicatiuon of apoxy flooring shall be done by authorised applicator. |
| 53 | Expanded metal,exc 4 kg/sqm cut to length,bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified amd directed |
| 54 | M & L steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified amd directed |
| 55 | M& L Steel work in tubular post 10mm Dia including special shaped washer etc complete using ERW or including butt welded tubes conforming to I.S-4923-1979 grade St -2240 including rolled mild steel as in joist channel ,angle,or tee sections fixed independently , without connecting plates , etc (cut to ordinary legth ie within 20mm of tile length indicated of gde Fe 410 -S ,complete all as specified amd directed |
| 56 | M & L Mild steel screw bolts (machine made ) with hexagonal or square heads at one end and screwed the other or screwed both ends ,each screwed end to be fiitted with washer and one hexagonal or square nut length of bolt exc 5 cm but n exc 10cm long complete all as specified amd directed . Please Enable Macros to View BoQ information |