| 1 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 2 | Brick work with F.P.S. bricks of class designation 75 insuperstructure above plinth level upto floor V level in allshapes and sizes in :5.2.1 Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 3 | Half brick masonry in Superstructure , above plinth level uptofloor V level using bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 4 | Providing and laying cement concrete including curing,compaction etc. complete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns,piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks,plain window sills, fillets, levelling course etc up to floor fivelevel excluding the cost of centering and shuttering. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate20mm nominal size). |
| 5 | Providing and fixing 1st quality standard white, grey, ivory,fume red brown, light green, light blue and other light shadesceramic glazed vitrified tiles with water absortion less than orequal to 0.08% confirming to IS:13753 & IS : 15622 on walls,pillars etc. laid on a bed of neat cement slurry finished withflush pointing in the white cement mixed with pigment tomatch the shade of the tile complete (excluding the cost ofcement plaster on walls and pillar).7.20.1 Size 600mm x 1200mm |
| 6 | Add extra for Fixing glazed/ Ceramic/ Vitrified floor tiles withcement based high polymer modified quick-set tile adhesive(Water based) conforming to IS: 15477 , using 5kg. adhesiveper sqm of tile area, in average 3mm thickness instead ofcement mortar. |
| 7 | Plaster on new surface on walls in cement sand mortar 1:4including racking of joints etc. complete fine finish :12.2.1 20 mm thick. |
| 8 | Removing white or colour wash by scrapping and sandpapering and preparing the surface smooth including necessaryrepairs to scratches by sandla/loi. (only for colour changing ). |
| 9 | Providing and applying white cement based putty overplastered surface to prepare the surface even and smoothcomplete12.22.1 New Plastered Surface (three or more coats) |
| 10 | Applying one coat of Cement primer of approved brand andmanufacture on wall surface including all scaffolding: |
| 11 | Wall painting with plastic emulsion paint of approved brandand manufacture to give an even shade including allscaffolding:12.40.1 Two or more coats on new work including prepartion of basewith primer, putty, lippy etc complete in all respect. |
| 12 | Providing and applying superior quality emulsion for wallpainting with Velvet touch/Royal paint etc of approved brandand manufacture to give an even shade with putty andpreparation of surface applying with the help of paint roller thework complete in all respect as per direction of Engineer-incharge.12.64.1 New Work Three or More coat |
| 13 | Providing and fixing 15 mm thick densified tegular edged ecofriendly light weight calcium silicate false ceiling tiles ofapproved texture as per direction of Engineer-in-charge ofsize 595 X 595 mm in true horizontal level suspended oninter locking metal grid of hot dipped galvanized steelsections (galvanizing @120 grams per sqm) consisting ofmain „T‟ runner suitably spaced at joints to get requiredlength and size of 24X38mm made from 0.33 mm thick(minimum) sheet, 1200mm centre to centre, and cross „T‟ ofsize 24X32mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main „T‟ at 600mm centre tocentre to form a grid of 1200X600mm and secondary cross‟T‟ of length 600mm and size 24X32mm made out of 0.33mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mmresting on periphery walls/partitions on a perimeter wall angle precoatedsteel of size (24X24X3000mm made of 0.40mm thick(minimum) sheet with the help of rawl plugs at 450mm centreto centre with 25mm long dry wall screws @ 230mm intervaland laying 15mm thick densified edged calcium silicate ceiling tiles of approved texture in the grid including cutting/making opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc., wherever required, Main „T‟ runners to be suspended from ceiling using 50 mm long M 6 dash fasteners, 6mm G.I. fully threaded rods with galvnised steel L cleat level adjusters of size 80x25x2mm, spaced at 1200mm centre to centre long main „T‟ bottom exposed with 24mm of all T-sections shall be pre-paintedwith polyster baked paint, for all heights, as per specifications, drawing and as directed by engineer-in-charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs)having area less than 0.30 Sqm. The calcium silicate ceiling tiles shall have NRC. |
| 14 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work(i) Full Edge moulding |
| 15 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with whitecement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. South Zed Black Above 3601 Cm2 Slabs |
| 16 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 17 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :35 mm thickDecorative teak veneer both side |
| 18 | Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry :Size 125 x 100mm |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 20 | French sprit polishing :Two or more coats on new work including a coat of wood filler. |
| 21 | Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
| 22 | Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent with pair of CP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. |
| 23 | Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R- 410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 1.5 TR ISEER not less then 3.8 |
| 24 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own inhouse NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 25 | Armoured 2 core x 2.5 Sq.mm |
| 26 | Armoured 2 core x 1.5 Sq.mm |
| 27 | Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be prsent. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapourbarrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 28 | 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 29 | 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 30 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 100 mm dia per running inch length |
| 31 | Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 32 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 33 | Short point (up to 3 mtr.) |
| 34 | Medium point (up to 6 mtr.) |
| 35 | Long point (up to 10 mtr.) |
| 36 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket,Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 37 | On board |
| 38 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, ound / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated river, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum ower consumption should not more than the specified rating nd Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name ngraved/ Embossing/ Screen printing on housing. OEM must ave its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer nnexure \\"A\\" attached with this BSR , Minimum lumen output 1950 lm |
| 39 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 40 | P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Opening of following size and made out from 24 SWG GI sheet as per instructions of Engineer in charge including fixing with suitable fasteners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Suitable for 450 mm sweep Exhaust Fan |
| 41 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 42 | 1 x 1.5 sq.mm |
| 43 | 1 x 2.5 sq.mm |
| 44 | 1 x 4.0 sq.mm Please Enable Macros to View BoQ information |