| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed by Engineer in charge. All kinds of soil including carriage of materils in all leads and lifts. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) including carriage of materils in all leads and lifts. |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 4 | Foundations, footings, bases of columns, etc. for mass concrete |
| 5 | Lintels, beams,plinth beams, girders, bressumers and cantilevers. |
| 6 | Suspended floors, roofs, landings, balconies and access platform. |
| 7 | Columns, Pillars, Piers, Abutments, Post sand Struts |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) i/c carriage of material in all leads and lifts. |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement 1.5 oarse sand 3 graded stone aggregate 20 mm nominal size). i/c carriage of material in all leads and lifts. |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering finishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) i/c carriage of material in all leads and lifts. |
| 11 | Steel reinforcement for R.C.C work including straightening, cutting,bending, placing in position and binding all complete above plinth level. TMT bars of grade Fe-500D or more i/c carriage of materils in all leads and lifts. |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. i/c carriage of material in all leads and lifts. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. i/c carriage of material in all leads and lifts. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 15 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes i/c carriage of material in all leads and lifts. |
| 16 | Providing and fixing steel door windows and ventilator standard steel hollow section size outer frame 70x50 mm thick & Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete , Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides & M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat & final paint coat with approved paint & Pdg. & fixing glass fiber sheet including all necessary fitting i.e. tower bolt, handle etc.. including carriage of material in all lead and lift. |
| 17 | Providing and fixing stainless steel powder coated sliding door bolts of required color and shade with bolts and nuts, screws etc complete including carriage of material in all leads and lifts.250x16 mm |
| 18 | Providing and fixing stainless steel powder coated tower bolts (barrel type) of required shade and colour with screws, etc. complete including carriage of material in all leads and lifts.200x10mm |
| 19 | Providing and fixing stainless steel powder coated handles to required colour and shade with necessary screws, etc. complete including carriage of material in all leads and lifts.125mm |
| 20 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600X600 mm |
| 21 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of tile 600X600 mm |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter. |
| 23 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion including carriage of material in all leads and lifts |
| 24 | Bend 87.5° 110 mm bend |
| 25 | PVC plain shoe 110 mm diameter |
| 26 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.including carriage of material in all leads and lifts:-110 mm diameter |
| 27 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) upto any height /Depth i/c carriage of material in all leads & lifs. |
| 28 | 15 mm cement plaster on rough side of single or half brick wall of mix upto all heights/depths in mement Mortor 1:6 (1 cement: 6 coarse sand).i/c carriage of material in all leads & lifts |
| 29 | 20 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) upto all heights i/c carriage of material in all leads & lifts. |
| 30 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 31 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer including carriage of material in all leads & lifts. |
| 32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm including carriage of material in all leads & lifts. |
| 33 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. Please Enable Macros to View BoQ information |