| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group C |
| 3 | Makes:- (KEI/Anchor/Finolex/L&T(Entice)/Legrand(Myrius)/Schneider(Livia) |
| 4 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 5 | (Makes:-KEI,Anchor,Finolex) Legrand (Myrius), L&T(Entice), Schneider(Livia) |
| 6 | Wiring for circuitl submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 7 | 2x1.5 Sq. mm. |
| 8 | 2x4 Sq. mm. |
| 9 | 2x10 Sq. mm. |
| 10 | 2x16 Sq. mm. |
| 11 | 4x4 Sq. mm. |
| 12 | 4x10 Sq. mm. |
| 13 | 4x16 Sq. mm. |
| 14 | (Makes:-KEI / Anchor / Finolex) |
| 15 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel PVC conduit as required. |
| 16 | 3x1.5 Sq. mm. |
| 17 | (Makes:-KEI / Anchor / Finolex) |
| 18 | Supplying and fixing of following sizes of medium class PVC conduit along with accesssories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 19 | 50mm dia. |
| 20 | (Makes:-BEC Plast / Anchor / Finolex) |
| 21 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 22 | 2 Modules |
| 23 | 8 Modules |
| 24 | Makes:- L&T/Legrand/Schneider. |
| 25 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 26 | 5/10 Amps. Modular switch |
| 27 | 5/6 amp modular socket outlet |
| 28 | 25 Amps. 1 Way Modular switch with indicator |
| 29 | Socket 10A/25A Combined 2M |
| 30 | Makes:- L&T/Legrand/Schneider. |
| 31 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. |
| 32 | Makes:- Legrand/L&T/Schneider. |
| 33 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. |
| 34 | Makes:- Legrand/L&T/Schneider. |
| 35 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- |
| 36 | Single Pole. Cat-A. |
| 37 | Makes:- Legrand/L&T/Schneider. |
| 38 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 39 | 40 Amp., Double pole |
| 40 | 63 Amp., Double pole |
| 41 | Makes:- Legrand/L&T/Schneider. |
| 42 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 43 | 63 A, Four Pole |
| 44 | Makes:-Legrand/L&T/Schneider. |
| 45 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 46 | 40 Amp., Double pole |
| 47 | 63 Amp., Double pole |
| 48 | Makes:- Legrand/L&T/Schneider. |
| 49 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 50 | 12 Way, Double door |
| 51 | 16 Way, Double door |
| 52 | Makes:- Legrand/L&T/Schneider. |
| 53 | Providing and fixing Double door 04 Way PPI DBs, available in CRCA sheet steel, RAL 9003, powder coated Provided with 100A insulated phase bus-bars, neutral bars with shrouds, earth bars, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification labels With provision for FP MCB/Isolator/RCCB/RCBO as incomer, DP RCCB/RCBO as sub-incomer and SP MCBs as outgoings as required complete in all respects. |
| 54 | 04 Way PPI DB Hrz. |
| 55 | Tier PPI DB - 8 Way |
| 56 | Makes:- L&T/Legrand/Schneider. |
| 57 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 58 | Earthing with Copper earth plate 600 mmx600 mmx 6 mm thick |
| 59 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, Copper tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 60 | Lightning conductor finial, made of 25 mm dia 300 mm long copper |
| 61 | Providing and fixing Copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. |
| 62 | Copper tape 20 mm x 3 mm thick (For Vertical run) |
| 63 | Copper tape 20 mm x 3 mm thick (For Horizontal run) |
| 64 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 65 | 8 SWG Copper Wire |
| 66 | Providing, installation, testing and commissioning of BLDC ceiling fan with socket type regulator, including wiring the down rods of strandard length (upto 30cm) with 16/0.20mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required with five years warranty. |
| 67 | Ceiling Fan 1200mm sweep (BLDC) |
| 68 | Makes:- Usha/Bajaj/Crompton |
| 69 | Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required. |
| 70 | Exhaust Fan, Light duty, (Domestic) |
| 71 | Makes:- Usha/Bajaj/Crompton |
| 72 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required. |
| 73 | Armoured Cable 70 Sq.mm. (3.5 core) |
| 74 | Armoured Cable 120 Sq.mm. (3.5 core) |
| 75 | Makes:- KEI/Polycab/Havells |
| 76 | Providing and fixing decorative LED mirror light having high quality design suitable for LED tube up to 10Watt (1000 lumen) 6500K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, complete with all accessories, connections, testing and commissioning etc. as required. With 5 year waranty. |
| 77 | 10 Watt LED Mirror Light, 2 ft. |
| 78 | Makes:- Bajaj/Havells/Philips |
| 79 | Providing and fixing of LED fixture 600mm x 600mm 36Watt +/- 1W recess/surface mounted having minimum system lumen efficacy of 100lm/W with with CRCA housing and PMMA diffuser with P.F. >0.95, THD<10%, CCT 5700K, CRI 80. The LED shall be tested with LM80-08 standard with useful life of 50000 hrs. at L70. The input voltage range shall be 150V as required complete with connections, testing etc.With 5 year waranty. |
| 80 | 36 Watt LED 2'x2' Recess/surface panel |
| 81 | Makes:- Panasonic/Wipro/Havells |
| 82 | Providing and fixing decorative extruded tube fixture having high quality design suitable for LED tube up to 18Watt (1800 lumen) 6500K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, including one no. tube rod 18 Watt complete with all accessories, connections, testing and commissioning etc. as required. complete in all respects.With 5 year waranty. |
| 83 | LED 18 Watt Tube fixture |
| 84 | Makes:- Philips/Wipro/Havells |
| 85 | Providing and installation of LED fixture 18W +/- 1W LED round/square surface/recess mounted downlighter with minimum system lumen efficacy of 85 lm/W with and P.F. >0.95 with THD <20%, CCT 6000K, CRI 80. The LED with useful life of 50000 Hrs. at L70. The input voltage range shall be 150V as required complete with connections, testing etc.With 5 year waranty. |
| 86 | 18 Watt LED round/square Surface/recess |
| 87 | Makes: Usha/Bajaj/Crompton |
| 88 | Providing and fixing of LED Bulkhead 10W +/- 1W with minimum system lumen efficacy of 100 lm/W with and P.F. >0.95 with THD<10%, CCT 5700 K, CRI 70, surge protection 4 kV. The LED with useful life of 50000 hrs. at L70 with 5 years warranty. The input voltage range shall be 150V to 270V as required with all accessories, i/c connections, testing and commissioning etc. as required complete in all respects. |
| 89 | LED Bulk Head, 10 Watt |
| 90 | Makes:- Bajaj/Wipro/Havells |
| 91 | Supplying and fixing of LED street light luminaire with the use of the latest technology 45 Watt (4500 lumens), 6500K made of CRCA housing and it should be compatible with specifications i.e. power factor ≥ 0.95, harmonic distortion ≤ 10% and efficacy ≥ 80 lumens per watt, CRI > 70, suitable for input voltage AC 150-270V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.as required.With 5 year waranty. |
| 92 | LED 45 Watt Street light |
| 93 | Makes:- Bajaj/Wipro/Havells |
| 94 | Supplying and erection of following depth sheet metal cubical main panel/pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of MCCB's, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, Main Power Panel made out of M.S. CRC Sheet 14/16G, base frame 75 x 40 x 3 mm channel duly painted with Siemens grey powder coated paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form. The cubical panel shall be including MCCB 200A 4P as incomer, MCCB 63 A 4 Pole 5 Nos. as outgoings, Digital Metering set and busbar copper 300 Amp. and the panel should be approved/tested from the CPRI Lab and should be confirm to IS 64139 as required complete in all respects. |
| 95 | Light & Power Panel - MCCB 200A 4P 25 kA as incomer |
| 96 | Supplying and erection of following depth sheet metal cubical main panel/pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of MCCB's, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, Main Power Panel made out of M.S. CRC Sheet 14/16G, base frame 75 x 40 x 3 mm channel duly painted with Siemens grey powder coated paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form. The cubical panel shall be including MCCB 400A 4P as incomer, MCCB 250 A 4 Pole 1 Nos., MCCB 200 A 4 Pole 1 No, MCCB 125 A 4 Pole 1 No, MCCB 100 A 4 Pole 1 No, MCCB 63 A 4 Pole 1 No as outgoings, Digital Metering set and busbar copper 500 Amp. and the panel should be approved/tested from the CPRI Lab and should be confirm to IS 64139 as required complete in all respects. |
| 97 | Main Panel - MCCB 400A 4P 36 KA as incomer Please Enable Macros to View BoQ information |