| 1 | M&L for preparation of old surfaces by complete removal of existing treatment of painted walls incl pillar etc. by mechanical equipments like electric wall sander/water jet machine and applying cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coat of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturer's specification complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for preparation of old surfaces by complete removal of existing treatment of painted ceiling incl beams etc. by mechanical equipments like electric wall sander/water jet machine and applying cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coat of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturer's specification complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L for preparation of old surfaces by complete removal of existing treatment of painted wall/ceiling incl pillar etc. by mechanical equipments like electric wall sander/water jet machine and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces complete, by mechanical means as per manufacturer's specification complete all as specified and directed by Engineer-in-Charge. |
| 4 | Taking down cement plastering at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L rendering 15 mm thick in CM 1:6 on brick masonry or concrete surfaces of walls finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for preparation of new surfaces of walls incl pillar etc. and applying cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coat of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturer's specification complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L for rendering 15mm thick in 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins facia etc in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5 mm in CM 1:4 mixed with liquid water proofing liquid (ISI marked) @ 200ml/bag of cement or as per manufacturer’s instructions upto 3 storey height, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note :- Supply only water proofing liquid shall be measured and paid separately under relevant items. |
| 8 | Supply only integral water proofing liquid complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for preparation of new surfaces of wall/ceiling incl pillars etc. and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces by mechanical means as per manufacturer's specification complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & fair without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for preparation of new surfaces of ceiling incl beams etc. and applying cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coat of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturer's specification complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for preparation of surfaces and applying one coats of oil bound distemper with roller on old treated surface of wall etc complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for preparation to old decorated, plastered or unplastered surfaces of ceiling, by brooming down, scraping down smoke spots, moulds, mossand efflorescent salts etc. and applying one coat of white (lime) wash including cornices pilasters etc complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material and labour for preparation of wall/ceiling surfaces and applying 1.5mm thick cement based external wall care putty on old or new plaster surface complete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L for preparation to old painted surfaces of wood or wood based material over 10cm width or girth of any description & applying one coat of synthetic enamel paint by mechanical means complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for preparation to old painted surface of steel over 10cm width or girth of any description & applying one coat of synthetic enamel paint by mechanical means complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for preparation of surfaces and applying one coats of cement base paint on old treated surface of wall etc complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 18 | M&L for preparation of surfaces and applying one coats of cement base paint on old treated surface of wall etc complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |