| 1 | SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS. |
| 2 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 3 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed. |
| 4 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed. |
| 5 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed. |
| 6 | Dismantling timber scantlings unframed work in fillets, rails, posts, rafters, purlins, etc. under 40 Sqcm in section, in any position, complete all as specified and as directed. |
| 7 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed. |
| 9 | Dismantaling of brickwork or stone/ boulder/ block masonry, including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar of any description, complete all as specified and as directed. |
| 10 | Taking down PVC pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories, complete all as specified and as directed. |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. |
| 12 | Dismantling water tanks capacity exceeding 500 Litres but not exceeding 1000 Litres and removing to store, complete all as specified and directed. |
| 13 | Pre-painted galvalume aluminium zinc coating galvanised iron based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 14 | Pre-painted galvalume aluminium zinc coating galvanised iron based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 15 | Galvanised, corrugated mild steel sheeting 0.63mm thick, with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws, in roofs, walls etc. with grade of zinc coating 275, complete all as specified and as directed. |
| 16 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation filling, complete all as specified and as directed. |
| 17 | Plain cement concrete M-10(1:3:6), type C-1, (using 40mm graded crushed stone aggregate), nominal mix in surface channels and drains, including necessary form work, complete all as specified and as directed. |
| 18 | Pre-cast cement concrete block masonry M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) with solid blocks, exceeding 10cm in width and incluing setting in cement mortar 1:6, complete all as specified and as directed. |
| 19 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 20 | Preparation of new plastered surfaces of walls and applying two coats of cement paint over one coat of priming plastered and other surfaces with alkali resistant priming paint, complete all as specified and as directed. |
| 21 | Vitrified Ceramic tiles of light shade, 10mm thick (square/ rectangular) polished, non-skid, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 22 | Vitrified Ceramic tiles of light shade, 10mm thick (square/ rectangular) polished, non skid area of each tile not exceeding 0.36 Per Square Metre, in skirting or in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including fixed over screed bed or bedding layer of mortar 10mm thick in cement mortar 1:4, complete all as specified and as directed. |
| 23 | Non-skid, coloured, ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 Per Square Metre but not exceeding 0.38 Per Square Metre, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 24 | Glazed ceramic coloored tiles in vertical surface/ dado, size 300x200x6/7mm, 300x450x6/7mm, 350x250x6/7mm, or 450x350x6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including rendering of 10mm thick in cement mortar 1:4 as backing of tiles, complete all as specified and as directed. |
| 25 | Harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc, suitable for curtains, complete all as specified and as directed. |
| 26 | Pressed steel frames for doors of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed. |
| 27 | Flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete al as specified and as directed. |
| 28 | Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, having 140mm overall length of cover plate, fixed in floor, complete all as specified and as directed. |
| 29 | Mortice lock, brass, vertical type, size 100 mm, 4-lever, suitable for aluminium door, complete all as specified and as directed. |
| 30 | Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed. |
| 31 | Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed. |
| 32 | Extruded aluminium alloy handles, fabricated type, anodised, size 150mm, complete all as specified and as directed. |
| 33 | Anodised aluminium snap grid frame work for false ceiling, powder coated, comprising of aluminium Tee (weight of section not less than 280 gms/mtr) and aluminium angle (weight of section not less than 280 gms/mtr), grid size 605x605mm, including Hangers 6.0mm dia, galvanised iron (upto1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3 mm size 60mm long and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed. |
| 34 | Providing and fixing everest board 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, grid size 595x595mm, for false ceiling all as specified, complete all as specified and as directed. |
| 35 | Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed. |
| 36 | Plywood, grade BWP, type BB, having 05 Nos of ply and 6mm thick, fixed with nails to timber frame work in walls, complete all as specified and as directed. |
| 37 | Plain fillets size exceeding 13.0 Sqcm but not exceeding 25.0 Sqcm, square, rectangular or triangular in section, made with second class hardwood, clean sawn, secured with nails, complete all as specified and as directed. |
| 38 | Plain fillets size exceeding 3.0 Sqcm but not exceeding 6.0 Sqcm, square, rectangular or triangular in section, made with second class hardwood, clean sawn, secured with nails, complete all as specified and as directed. |
| 39 | PVC sheet fillet 5mm thick of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and as directed. |
| 40 | Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and as directed. |
| 41 | PVC (SWR) pipes, 110mm bore, single socketed, capacity not, less then 4.50 Kgf/Sqcm, in any length fixing with adhesive/ solvent cement, laid in trenches or in floors, complete all as specified and as directed. |
| 42 | PVC (SWR) pipes, 75mm bore, single socketed, capacity not, less then 4.50 Kgf/Sqcm, in any length fixing with adhesive/ solvent cement, laid in trenches or in floors, complete all as specified and as directed. |
| 43 | PVC (SWR) bends of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed. |
| 44 | PVC (SWR) bends of 75mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed. |
| 45 | PVC (SWR) floor trap, 75mm diameter of outlet, plain with grating including jointing with adhesive, complete all as specified and as directed. |
| 46 | Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) with lid, hoisted and fixed in position all as specified in SSR Part-I including ball valves high pressure of PTMT with epoxy coated aluminium rod and highdensity plastic ball screwed for iron pipe and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed. |
| 47 | Angle/ Stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed. |
| 48 | Bib taps, cast copper alloy, chromium plated, fancy type, long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed. |
| 49 | PVC connections 15mm size with brass nuts, of length 450mm, fixing in repairs, complete all as specified and as directed. |
| 50 | Brass chromium plated basin mixer for mixing hot and cold water screwed down for iron pipe and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed. |
| 51 | Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 52 | Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed. Please Enable Macros to View BoQ information |