|
| 1 | Supply and erection of fancy/ decorative lights of following types / specifications including making connection, testing and commissioning etc. as selected by occupant of house. The job includes cost of LED lamps, (As per Complete Item No. 1 of the DNIT). |
| 2 | Fancy bollard in military green colour |
| 3 | Supply & erection of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 250mm sweep only. (As per Complete Item No. 2 of the DNIT). |
| 4 | DSR ITEM NO. 9.2Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, (As per Complete Item No. 3 of the DNIT). |
| 5 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 6 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 7 | DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | 3 x 1.5 sq. mm |
| 10 | 3 x 2.5 sq. mm |
| 11 | 4 x 1.5 sq. mm |
| 12 | DSR Item No. 1.10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 13 | Group B |
| 14 | DSR item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 15 | DSR item No.1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 16 | DSR item No.1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 17 | DSR ITEM NO. 8.9.5Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, (As per Complete Item No. 10 of the DNIT).). |
| 18 | 18-22 watt |
| 19 | DSR Item No. 8.13.7LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, (As per Complete Item No. 11 of the DNIT). |
| 20 | 25 Watt |
| 21 | DSR Item No. 8.16.3LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, (As per Complete Item No. 12 of the DNIT). |
| 22 | 100 Watt |
| 23 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Single pole |
| 25 | Triple pole and neutral |
| 26 | Triple pole |
| 27 | DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, (As per Complete Item No. 14 of the DNIT). |
| 28 | 12 way (4 + 36), Double door |
| 29 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, (As per Complete Item No. 15 of the DNIT). |
| 30 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 31 | Supply & erection of Cabin Fan 16” sweep oscillating type complete with blades & regulator. The fan should have 2 of pull cord switches, one for oscillation and one for speed regulation. The fan should be of Havells make Swing / Crompton make WM Wind FIO (HiSpeed) / Orient make 400 mm (16\\") Wall-45/ Bajaj make media BW07 400 mm wall only. (As per Complete Item No. 16 of the DNIT). |
| 32 | DSR item No.1.18 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 33 | 4 Pair |
| 34 | DSR Item No. 39.17 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard., (As per Complete Item No. 18 of the DNIT). |
| 35 | 1 Run of cable |
| 36 | S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. (As per Complete Item No. 19 of the DNIT). |
| 37 | DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 38 | 100 A,36KA,FPMCCB Please Enable Macros to View BoQ information |