Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving not exceeding 15cm thickness (below or above ground level) etc. complete all as specified and directed. |
| 2 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement sime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 3 | M&L for Brickwork with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 4 | All as per description of item No 3 above but except bricks etc. complete all as specified and directed. |
| 5 | M& L for Brick work with sub class 'B' bricks using old size bricks straight or curved on Sqm plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed |
| 6 | Dismantling of Brick tiles or terracing tiles, single layer on roofs complete all as specified and directed. |
| 7 | Demolition of Mud in roof, any thickness, including plastering and leeping (whether full thickness removed or a part thereof) complete all as specified and directed. |
| 8 | M&L for roughening surfaces of old/concrete floor by backing sweeping clean and washing down with water etc. complete all as specified and directed. |
| 9 | M & L for PCC padding 1:2:4, type B-1(using 20 mm garded stone aggregate) as in roof padding in specified slope complete all as specified and directed.. |
| 10 | M&L for 15mm thick screed bed or bedding layer of mortar in CM 1:4, using WPC complete all as specified and directed. |
| 11 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application, over a coat of hot blown bitumen 85/25 1.20 kg/Sqm complete all as specified and directed. |
| 12 | M&L for 40 mm thick brick tiles laid over and including cement mortar 1:6 and joints grouted flush in CM 1:3 mixed with 5% of crude oil by weight of cement. complete all as specified and directed. |
| 13 | All as per item No. 12 above but except tiles complete all as specified and directed. |
| 14 | M&L for flush pointing to brick tiles, laid flat in cement mortar 1:3 complete all as specified and directed. |
| 15 | M&L for cement concrete type B-1, 1:2:4 (20 mm graded) in roof kerbs or mud stops rounded or chemfered edges complete all as specified and directed. |
| 16 | Supply only integral waterproofing compound complete all as specified and directed. |
| 17 | Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed |
| 18 | M &L for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:-(i) Application of Two component acrylic modified cementitious coating(aa) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coating and achieve a gripping profile that is clean, dry and free from laitance and dry other form of surface contamination. The installation instructions in manufacture's published literature should be strictly complied with, including but not limited to the following:-(bb) Chipping out any visible cracks in \\"V-Groove\\" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/Dr Fixit 302 SBR latex/ Perma latex SBR/FOSROC Nitabond SBR latex/Asian paint latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required.(cc) Dampen all surfaces immediately ahed of application of Acrylic modified Cementitious coating of sika Top Seal-107/Brush Bond FOSROC/Dr Fixit/STP/CICO.(dd) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified cementitious coating of SIKA Top Seal-107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions. (ee) Apply glass fabric sheet of SIKA Fab 1/FOSROC/Dr Fixit/STP whilst the first coat is wet.(ff) Once touch dry, apply second coat of Acrylic modified cementitious coating of SIKA Top Seal -107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions on the entire area.(gg) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat.(hh) The waterproofing coating should be taken to a height minimum 300mm above the finished floor level on the vertical surfaces.(jj) It is essential to cure Acrylic modified cementitious coating immediately after application (minimum 6-8hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking.(kk) A protection plaster 12-15mm thick) in CM 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645. Providing and applying a protection screed of 50mm thick 1:4, cement sand mortar admixed with SIKA Plastocrete over the applied water proofing coating on horizontal surfaces. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645.(ll) All the corners and joints should be pretreated with an elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of Make SIKA Seal Tape/FOSROC/Dr Fixit/STP.(mm) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations.(nn) Waterproofing treatment has to be carried out through applicators authorised by the respective manufacturer's and approved by GE.(ii) All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealent.(iii) All CI traps in sunken slab to be enclosed with PCC 1:1.5:3 (Min 15cm) all around.(iv) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40mm stone aggregate) complete all as specified.(v) Providing drainage spout pipe GI pipe 40mm dia bore light grade upto outside of outer wall ( Approx 450mm to 600 mm long ) including cutting to existing wall and making good the disturbed surface complete all as specified and directed.(vi) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring for laying floor finish all as specified.Note:-Item No 18 (iv) ,(v) &(vi) shall be measured and paid seprately. |
| 19 | M&L 25 mm thick cement concrete flooring type B-1, 1:2:4 using 20 mm graded stone aggregate finishing cement concrete surface even and smooth without using extra cement. |
| 20 | M&L for cement concrete type E-2, 1:5:10 (using 40 mm graded stone aggregate) as in sunken flooring. |
| 21 | M & L for 50mm dia GI pipe,med grade beveled cut at both ends by making hole in walls sunken portion aprox above the RCC slab and ceiling finished the hole with cement plaster 1:2 to match with existing surface complete etc.(Measured for cutting holes shall be paid in concerned sch item) |
| 22 | M&L for joint free non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 23 | All as per item No 22 above but in vertical surfaces such as skirtings, dados and risers to steps etc, laid over and including 10mm thick cement plaster in CM 1:4 complete all as specified and directed. |
| 24 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 25 | M&L for coloured glazed ceramic tiles in vertical surface 450x300x7 mm thick laid over Sqm and including 10mm thick cement plaster in CM 1:4, set and jointed in neat cement slurry and pointed in white or colour cement to match. Complete all as specified |
| 26 | Demolition of reinforced cement concrete(reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for. complete all as specified and directed. |
| 27 | M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 28 | Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal/sloping), fair finished surfaces concrete flat, complete all as specified and directed. |
| 29 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to. complete all as specified and directed. |
| 30 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over and including cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed. |
| 31 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed. |
| 32 | Taking up or down Steel Tubing bore of pipe in 15mm and connections, including cleaning for refixing or removal to store etc complete all as specified and directed. |
| 33 | All as per item No. 32 above but of 20mm bore. complete all as specified and directed. |
| 34 | S&F Steel Tubes Medium Grade Bore of tube in 15mm galavanised with all fitting laid in trenches, walls, ceiling or laid in floors etc. complete all as specified and directed. |
| 35 | All as per item No. 34 above but of size of 20mm bore complete all as specified and directed. |
| 36 | S&F vitreous china under counter top Wash Basin, snow white, oval type of size 560mm x 470mm x 190mm including brackets, cutting for and pinning in ends of brackets or eracting stand & waste pipe, coupling etc complete all as specified and directed. |
| 37 | S&Fin repair vitreous china wash down water closet, \\"Orissa pattern, size, 580x440mm white, with integral foot rest (excluding flushing cistern and flush pipe) but including trap provision of cement concrete bedding. complete all as specified and directed. |
| 38 | S&F in repair vitreous china wash down water closet pan white excluding fixing bolts, flushing cistern and flush pipe with and incl 'P' or 'S' trap and making good to floor to match with existing all as specified and directed. |
| 39 | S & F in repair Jet spray with holder for EWC 1.5mtr long suitable for 15mm dia for iron pipe or for brass ferrule all as specified & directed. |
| 40 | S&F in repairs plastic seat cover white for water closet pedestal pattern closed patter with flat bottom fixed with mild steel chromium plated or aluminium hinging device complete all as specified. |
| 41 | S&F in repair Low Level Flushing cistern PVC valveless syphonic action type, 10 Itrs capacity including supply pipe & fixing brackets of M.S. angle of size (25mmx25mmx3mm), 30 cm long in PCC (1:2:4) type B-1, block of size (10cmx10cmx10cm) on walls etc. complete all as specified and directed. |
| 42 | S&F in repair fancy type, brass chromium Plated stop valves/Angle valves, cast copper alloy, bore dia of pipe in 15mm, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 43 | S&F in repair fancy type, brass chromium Plated stop valves/Angle valves with long shank and cup (concealed type), cast copper alloy, bore dia of pipe in 15mm, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 44 | M&L for chromium plated long body bib tap cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe and fixed to 15mm bore pipe fixed as in repairs including taking down old tap of any description complete all as specified and directed. |
| 45 | Supply and fix in repair, 15mm bore swan neck pillar taps, cast copper alloy with capstan heads chromium plated, fancy type, screwed down high pressure with or without lettered Hot or Cold with long screwed shank and fly nuts, complete all as specified and directed by the Engineer-in-Charge |
| 46 | S&F PVC connection 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed. |
| 47 | S&F chromium plated grating 100 mm dia circular of approved make and fixing with cement mortar 1:3 on Nahani trap or floor trap complete all as specified and directed. |
| 48 | S&F in repair gun-metal, globe or gate valves for 20mm bore dia of pipe, with iron wheel head, screwed both ends for iron pipe and fixed to steel pipe or union, complete all as specified and directed. |
| 49 | Supply and fix in repairs shower rose of brass chromium plated with shower arm 195mm long with bend of 45 degree 15mm dia complete all as specified and directed. |
| 50 | S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. 55 S&F CP soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 51 | S&F in repair Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) |
| 52 | S&F Brass CP Soap dish, any type, fixed to plugs with chromium plated brass screws all as specified and directed. |
| 53 | S&F in repair looking mirror of size not execeeding 1.5 sqm of 5mm thick of selected quality glass, mounted on 6mm thick commercial ply wood and fixed to wooden plugs with chromium plated brass and cup washer complete all as specified and directed. |
| 54 | S&F in repairs vitreous china Urinal, Half stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed. |
| 55 | S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed. |
| 56 | S&F in repairs vitreous china urinal partition white of size 310x700 mm complete all as specified and directed. |
| 57 | S&F waste coupling including waste pipe suitable for WHB/urinals, of any bore dia of PTMT (half or full threaded), (Minimum weight 45gms) complete all as specified and directed. |
| 58 | Dismantling PVC water tank of capacity 2000 Ltr and S&F new rotational moulded polyethylene water storage tank of capacity2000 Itr (cylindrical vertical with closed top) hoisted and fixed in position all as specified including 20mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed. |
| 59 | Taking down eaves gutter and rain water pipes (any size and pattern), including all fittings, heads, shoes, bends, swan necks, etc. removal from site (measured overall as fixed along the centre line or fittings and accessories) complete all as specified and directed. |
| 60 | S&F 110 mm bore PVC(SWR) pipes single sockets in any length with rubber ring joints laid in trenches or in floors or fixed to walls with stack clamps ,Complete all as specified and directed by Engineer-In-Charge. |
| 61 | S&F 110 mm bore PVC(SWR) bend any radius complete all as specified and directed. |
| 62 | S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 63 | S&F PVC (SWR) floor trap of 110mm outlet dia, plain including jointing with solvent cement complete all as specified and directed. |
| 64 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to wall with stack clamps , laid in trenches or in floors complete all as specified and directed. |
| 65 | S&F 75mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed. |
| 66 | S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 67 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 68 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls, finished even and smooth without using extra cement, complete all as specified and directed.. |
| 69 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls, finished fair and even, complete all as specified and directed.. |
| 70 | M&L for 5mm thick Rendering in CM 1:3 on brick work or concrete surfaces on ceiling finished even and smooth without using extra cement etc complete all as specified and directed. |
| 71 | M&L for preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of primer, complete all as specified and directed. |
| 72 | M&L for preparation of new plastered surfaces and distempering walls with two coats of distemper ail emulsion, white or tinted over and including 1mm thick wall care putty including primer, complete all as specified and directed. |
| 73 | M&L for preparation of newly plastered surfaces and applying three coats of White Wash on ceiling etc complete all as specified and directed. |
| 74 | All as per item No. 73 above but over old surfaces of ceiling, including removal of existing treatment. complete all as specified and directed. |
| 75 | M&L for complete removal of existing treatment and applying two coats of oil emulsion distemper white or tinted over and including 1mm thick wall care putty including primer, complete all as specified and directed. |
| 76 | M&L for complete removal of existing treatment and applying two coats of cement base paint, complete all as specified and directed.. |
| 77 | Taking down chowkats or frames with shutters not exceeding 1.5 sqm each (without taking off shutters from the frames), complete all as specified and directed.. |
| 78 | Taking down chowkats or frames with shutters exceeding 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frames) complete all as specified and directed. |
| 79 | S&F solid PVC frame as in door, of size 50mm x47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube and edges will be painted to match with printed sheets, suppyling & fixing in opening as per specification & drawing, complete all as specified and directed.. |
| 80 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC sheet 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; & 5mm thick x 15mm wide PVC sheet beading use inside stiles and rails and decorative PVC beading of 10mm x 10mm (90 degree)used Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 81 | S&F stainless steel steel butt hinges cold rolled of size 100mm medium weight complete all as specified and directed. |
| 82 | S&F Aluminium anodised, barrel tower bolts 200mm long of extruded section and fixed, complete all as specified and directed. |
| 83 | S&F Aluminium handles, cast type anodised of size 150mm etc complete all as specified and directed. |
| 84 | Supply & fix factory made steel windows 1.25 mm thick Box type (primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises of glazed skeleton shutter EWR Sec 50mmx20mm and 1mm thick and two open able leaf consisting two Nos sash bar of 'T section 20mm x 3mm complete welded to frame with one vertical mullion of EWR box type 'T' section of size 60mmx25mm and 1.25mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1 using 20mm graded stone aggregate. Four Nos for each window including following fittings welded to framed shutter: (a) Holdfasts 150mm long 12mmx3mm made to shape per window -04 Nos, (b) Handle of Z Sec 20mmx25mm, 100mm long per leaf-01 No, (c) MS tower bolt 150mm long per leaf -02 Nos, (d) Z' sec 20mm x 25mm, 100 long stopper per leaf -01 No, (e) Cleat 55 mm long of hollow square 15mmx20mmx63mm welded to hinges per leaf-01 No, (f) MS pintal hinges of size 75mmx12mm per leaf-02 Nos. (g) Fabrication and fixing arrangement as per drawing No CEJZ/TD/1019, Sh 1/3 to 3/3 and No. CEJZ/TD/1020, Sh 1/3 to 3/3 |
| 85 | All as per item No 84 and above but window with glazed shutter. |
| 86 | S&F mild steel work as in as in grill gratings etc with ends of bars shouldered and or riveted or fixed in spike, framed guard bars barred iron doors ladders frame balusters walk ways confirming to Fe- 290, Gde E-165 complete all as specified and as directed |
| 87 | S&F Steel ventilator, fixed type with glazing bars complete all as specified and directed. |
| 88 | S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, complete all as specified and directed. |
| 89 | S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples, wooden beads to steel windows/wooden doors. complete all as specified and directed complete all as specified and directed. |
| 90 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint. |
| 91 | Repairing of RCC projections chajjas, roofs, facia etc by necessary preparation, scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC and providing cement concrete (1:1.5:3) using 12.5 mm graded crushed stone aggregate including necessary form work and reinforced with chicken wire mesh and rendering 15mm thick in cement mortar 1:3 in patches area not exceeding 5 sqm each and thickness of RCC member not exceeding 70mm at any height complete all as specified and directed. |
| 92 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in plinth protection finished even and smooth (without using extra cement), complete all as specified and directed.. |
| 93 | M&L for 25mm thick PCC 1:2:4 type B-0(using 12.5mm graded stone aggregate) as in floor finished even and rough to receive the topping layer complete all as specified and directed. |
| 94 | S&F 160 mm bore PVC(SWR) pipes single sockets in any length with rubber ring joints fixed to walls/floors complete all as specified and directed. |
| 95 | S&F stack clamps for bore dia of pipe 160mm, made out of 50 mm x 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 96 | S&F mild steel screw bolts (machine made) with hexagonal or Square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut, exceeding not exceeding 5 cm long, dia of shank 5 to 10 mm, complete all as specified and directed. |
| 97 | S&F factory made 2nd class hard wood 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer In-Charge. |
| 98 | S&F in repairs 6.40mm thick Rough cast wired glass not exceeding 0.75Sqm, glazing with oil putty in square, complete all as specified and directed. |
| 99 | M&L for preparation of new wood surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and directed.. |
| 100 | M&L for preparation of old painted wood based surface of any description over 10cm width of girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 101 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete ail as specified and directed by Engineer-In-Charge. |
| 102 | M&L for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 103 | S&F butt hinges 100mm size, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed. |
| 104 | S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed. |
| 105 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 250mm. complete all as specified and directed. |
| 106 | M&L for 10mm cement plaster on fair faces of brick work or concrete surfaces in CM 1:4, using WPC 3% by weight of cement. Complete all as specified and directed.(Note water proofing compound shall be measured and paid separately under appropriate dem) |
| 107 | M&L for PCC 1:2:4 Type B-0 (12.5 mm graded stone aggregate) as in bed blocks, coping, etc complete all as specified and directed. |
| 108 | M&L for cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in fleld using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less including necessary formwork to the sides/ edges of joints etc complete all as specified and directed. |
| 109 | M&L for forming 12mm thick Expansion joints including necessary formwork, if any required, tled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com pound Grade A complete all as specified and directed. |
| 110 | Dismantling structural steel work in cluding doors, gates but excluding framed truss etc.complete all as specified and directed. |
| 111 | S&F steel rolling shutters, 1.25mm thick laths with gear operated type with bevel gear box and crank handle, ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete: push pull or manual type complete all as specified and directed. |
| 112 | Dismanting galvanised (corrugated, semi-corrugated, etc.) sheets in roof coverings including ridges, transculent sheets etc complete all as specified and directed. |
| 113 | S&F Pre-painted galvalume aluminum zinc coating Gl based corrugated steel sheet 0.50mm thick of an colour having tonsile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 114 | Taking down carefully aluminium / copper point wiring (light / fan / socket or power)/power wiring complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors and one coat of putty and two coat of distemper as per existing colour complete all as directed . |
| 115 | Taking down unserviceable Submain/ Cable/ Service wire of any size as directed by Engineer-In-Charge. |
| 116 | Taking down main switch / DB as directed by Engineer-In-Charge. |
| 117 | M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLSH, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLSH type , copper multistranded cable as earth wire including pressed steel sunken boxes for mounting of MODULAR /PIANO TYPE switch/sockets and regulator and including modular type cover plate white colour all as specified and directed by EIC for: NOTE : All switches from 6 Amp to 25 Amp should be latest ISI marked as per IS 3854 : 1997. Sockets 6 Amp 3 Pin and 6/16 Amp 3 Pin combined should be latest ISI Marked as per IS 1293 : 1988 and should be supplied with shutters and shutters opening with phase and neutral simultaneously. The range should have all the types of Indian Standard or Multistranded International sockets range in their profile. The fan regulator should be of 2 Module, capacitor based, Hum Free and ISI marked as per IS 11037. All the switches, sockets, fan regulator etc should be completely IP 20 protected with no live part directly accessible.a) One light / fan / call bell point controlled by one, one way switch. |
| 118 | b) All as per Ser item No 117 above but for 5 amps socket on independent board |
| 119 | c) All as per Ser item No 117 above but for 5 amps socket on same board |
| 120 | All as per item No.117 above but with 2.5 sqmm multistranded copper multistranded conductor FRLS cable with 2.5 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board/AC plug. |
| 121 | Supply and fixing modular metal flush box 3 module complete all as specified and directed. |
| 122 | Supply and fixing modular metal flush box 4 module complete all as specified and directed. |
| 123 | Supply and fixing modular metal flush box 12 module complete all as specified and directed. |
| 124 | Supply and fixing modular white cover plate with frame, 3 module complete all as specified and directed. |
| 125 | Supply and fixing modular white cover plate with frame, 4 module complete all as specified and directed. |
| 126 | Supply and fixing modular white cover plate with frame,12 module complete all as specified and directed. |
| 127 | Supply and fixing modular Dummy plate complete all as specified and directed. |
| 128 | S & F switch MODULAR 6 Amps, flush button type, SP, one way, 230 Volts, AC |
| 129 | S & F switch MODULAR 16 Amps, flush button type, SP, one way, 230 Volts, AC |
| 130 | S & F socket out let multipurpose MODULAR 5 pin 6 Amps, flush type, 230 / 250 Volts |
| 131 | S & F socket out let multipurpose MODULAR 5 pin 6/16 Amps, flush type, 230 / 250 Volts |
| 132 | S & F MODULAR fan regulator step type 120W, 02 module complete all as specified and directed. |
| 133 | Supply and Fixing Ceiling rose, surface bakelite 65 x 50 mm 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size ,complete ,all as specified. |
| 134 | M & L for sub main wiring with two single core PVC insulated and unsheathed cable 6 sqmm with multi stranded copper conductor , FRLSH type cable drawn through and including PVC concealed conduit of 25mm in size complete with all accessories alongwith provn of 6 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLSH type cable as earth wire (Three runs of cable and one run of conduit shall be measured as one length) |
| 135 | Supply & fixing MCCB 4 pole of capacity 100 Amps with breaking capacity 16 Kilo Amps including all electrical connections and fixing arrangment complete all as specified and directed by EIC . Note- MCCB Should have reverse load and line termination, rotary handles – direct and variable depth and common auxiliaries for entire range. Should be CE marked and conform to IEC 60947-2. MCCB should have the maximum operational voltage ( Ue ) of 550 Volts (AC 50/60 Hz), Insulation Voltage ( Ui ) of 800 Volts and Rated Impulse Withstand Voltage (Uimp) not less than 8000 volts. The MCCB should have been designed at an ambient temperature of 50 degree centigrade. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED.For 16 – 125 A: Should have breaking capacity of min. 16 kA with thermal release adjustable from 80 to100 % & fixed magnetic release and with Ics = 100% Icu. |
| 136 | Supply and fix Sheet metal DB,double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc. Distribution boards should be Double Door design with IP-43 and IK-08 rating as per IEC 61439-3 with 100 Amp fully insulated copper busbars, insulated neutral bar, earth bar and cable ties for cable management. Distribution board should be supplied with door earthing, prefitted masking sheet, reversible doors and pan assembly for easy installation. Must have possibility of converting lock to panel lock complete all as specified and directed. |
| 137 | S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “B” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting. complete all as specified and directed. |
| 138 | Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “B” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting. complete all as specified and directed. |
| 139 | Supply and Fixing metal enclosure (plug & socket type DB) complete including single pole and neutral enclosure with two pin, earth plug and socket complete with one SP MCB of capacity 20 Amp, 10 KA all as specified and directed. |
| 140 | S&F in replacement LED tube light fitting 20W Box type including LED lamp 20 W with 2200 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed. |
| 141 | Supply and fix in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m as required for fixing and electrical connection upto ceiling rose complete all as specified and directed. |
| 142 | Supply and fixing of electric water heater,storage type steel body with SS 304 inner tank and heating element upto2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 143 | S & F SITC of high-quality integrated LED Street Light with a minimum system lumen of4750 Lm and system wattage not exceeding 45W with a nominal efficiency 105 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters complete all as specified and directed.. |
| 144 | M & L for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on and taking down old one complete all as specified and directed. Note :- (i) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. |
| 145 | Taking down unserviceable Cable of any size as directed. |
| 146 | Supply and laying XLPE insulated , armoured electric cable heavy duty with aluminium conductor , 1100 volts UG cable of size 4 Core 25 Sqmm. |
| 147 | Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exc 1.5M depth for laying of UG cables and getting out all as specified and directed |
| 148 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms thick of soil complete all as specified and directed. |
| 149 | M & L river sand in trenches as cable cushioning 8 cm below the cables and 15cm above the cable which is to be punned down to 10m all as specified and directed.only punned thickness will be measured. |
| 150 | Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed. |
| 151 | Supply and lay burnt bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed. |
| 152 | Supply and fixing /laying PVC conduit pipe 50mm bore light grade fixed to pole with clamps nuts, Bend/Tee/Junction box , bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed. |
| 153 | S & F switch Piano 5 Amps, flush button type, SP, one way, 230 Volts, AC |
| 154 | S & F switch Piano 1 5 Amps, flush button type, SP, one way, 230 Volts, AC |
| 155 | S & F socket out let multipurpose 5 pin 5 Amps,230 Volts |
| 156 | S & F socket combination ,6 pin ,15 amps, flush type, multipurpose, 230 Volts |
| 157 | Supply and fix MCB DB, TPN 6 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 250 amps rated bus bars , Neutral links , blanking plates Distribution boards should be Double Door design with IP-43 and IK-08 rating as per IEC 61439-3 with 100 Amp fully insulated copper busbars, insulated neutral bar, earth bar and cable ties for cable management. Distribution board should be supplied with door earthing, prefitted masking sheet, reversible doors and pan assembly for easy installation. Must have possibility of converting lock to panel lock. All 3 Phase horizontal distribution boards should have the provision to convert the distribution boards to Per Phase Isolation Distribution Board at site. All MCCB incomer distribution boards should be supplied with 250 Amp rated fully shrouded busbars complete all as specified and directed. |
| 158 | Supply & fixing MCCB 4 pole of capacity 63 Amps with breaking capacity 16 Kilo Amps including all electrical connections and fixing arrangment complete all as specified and directed .Note- MCCB Should have reverse load and line termination, rotary handles – direct and variable depth and common auxiliaries for entire range. Should be CE marked and conform to IEC 60947-2. MCCB should have the maximum operational voltage ( Ue ) of 550 Volts (AC 50/60 Hz), Insulation Voltage ( Ui ) of 800 Volts and Rated Impulse Withstand Voltage (Uimp) not less than 8000 volts. The MCCB should have been designed at an ambient temperature of 50 degree centigrade. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED.For 16 – 125 A: Should have breaking capacity of min. 16 kA with thermal release adjustable from 80 to 100 % & fixed magnetic release and with Ics = 100% Icu. |
| 159 | Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “B” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting. complete all as specified and directed. |
| 160 | Supply and Fixing stepped socket type electronic/BLDC type as per existing sample fan regulator and connecting up complete all as directed. |
| 161 | M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings. |
| 162 | S & F LED bulb 9 Watt White(6000K-6500 K)/Warm(2700K-3200K) with BEE Energy star rating of three star or more and emission of minimum 100 lm/W complete all as specified |
| 163 | Supply & fixing of 14 Watt Batten luminaire with Polycarbonate Housing with high quality extruded polycarbonate diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2100 nominal lumens and an outstanding System efficacy of at least 150 lumen/watt and maximum system wattage of 14 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <15% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 164 | Supply & fixing of 20 Watt Batten luminaire with Polycarbonate Housing with high quality opal finish diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an System efficacy of at least 100 lumen/watt and maximum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 165 | S&F SITC of high-quality LED Flood Light with a minimum system lumen of 12000 Lm and system wattage not exceeding 100 W with a nominal efficiency 120 lumen/watt. CCT of 5700K with CRI >70. The housing should be of pure polyester powder coated die-cast aluminum with high efficiency LEDs as lighting source. The fitting should have PC reflector for maximum output and PC Lens for symmetric distribution & tempered protective Toughened Glass with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 6 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 166 | S & F high speed wall mounted fan, heavy duty, copper winding of sweep size 450 mm complete with wide oscillation with motorised control including fitting and fixtures as per site requirement and two core PVC insulated, PVC sheathed copper conductor for connection all as specified and directed. Make : Crompton/Havells or equivalent Please Enable Macros to View BoQ information |
| 167 | S & F high speed wall mounted fan, heavy duty, copper winding of sweep size 450 mm complete with wide oscillation with motorised control including fitting and fixtures as per site requirement and two core PVC insulated, PVC sheathed copper conductor for connection all as specified and directed. Make : Crompton/Havells or equivalent Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail