| 1 | Excavation in post holes(or similar holes) each n. exc 0.5 Cum getting out in any type of soil and returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc exc 25 cm watering and removing surplus soil to a distance n exc 50 m and making good surface as in soft/loose soil complete all as specified and as directed. |
| 2 | M&L for cement concrete Type C-2, 1:3:6 (using 20 mm graded stone aggregate) in post foundation, foundation and mass concrete all as specified and directed |
| 3 | M&L PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified & directed. |
| 4 | S & F rolled sections as in post built up of one beam / channel or angle section with flanged plates, caps bases slices angle brackets cleats and other connections, conforming to Fe 410-w.(Gde-E-250 ) quality A complete all as specified and as directed. |
| 5 | S & F rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates, conforming to Fe 410-w.(Gde-E-250 ) quality A complete all as specified and as directed. |
| 6 | S & F for mild steel plates (plain or chequired) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde E-250) Quality -A complete all as specified and as directed. |
| 7 | M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying 2 coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 8 | \\"Supply, fabrication, and installation of minimum 700 GSM PVDF-coated architectural tensile fabric membrane (Serge Ferrari / Mehler / Sattler or approved equivalent) in approved color. Item includes 3D CAD patterning, high-frequency (HF) welding of joints, forming of end pockets, supply and inserting of heavy-duty Keder profiles, fixing with specialized anodized aluminum extrusions secured to the roof truss ends, mechanical tensioning to a wrinkle-free finish, hardware, sealants, scaffolding, tools, and labor, all complete as per structural drawings, specifications, complete all as specified and as directed. |
| 9 | M&L for PCC (1:4:8) type D-2 (using 40mm graded aggregates) as in sub base 75mm thick complete all as specified and as directed. |
| 10 | M&L for machine pressed precast concrete interlocking paver block square in shape of size 200mmx200mm white, grey and black in colour rough finished on top portion of confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and including 50mm sand bed under bed complete all as specified and as directed. |
| 11 | M&L precast cement concrete block masonry exc. 10 cm width with solid block C1 (1:3:6) (using 20 mm graded stone aggregate) and setting in cement mortar (1:6) all as specified and as directed. |
| 12 | M&L for Rendering 10mm thick CM 1:6 for finishing the surface even and smooth w/o using extra cement. |
| 13 | M&L Mild steel screw bolts 16 to 20mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and n exc 15cm long complete all as specified and as directed. |
| 14 | M&L Stainless steel safety stud anchor (Make- Hilti) 20mm dia 260mm long (HST3 M20 x 260) bolt, used with any injection system and glass capsules in masonry and concrete, chemically bonded all as specified by manufacturer complete. |
| 15 | M&L for preparation of newly plastered surfaces of wall by and applying two coats of cement based paint over one coat of primer all as specified. |
| 16 | M & L point wiring for One light/fan point controlled by one switch 5 Amps one way. complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified and directed.Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab. |
| 17 | M & L point wiring for one modular 3 pin 5 Amp socket out let on independent board complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified and directed.Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab. |
| 18 | M & L point wiring for 3 pin switch socket outlet , 5 Amps on same board .complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified and directed.Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab. |
| 19 | S&F switch modular type, 5 Amps 1 module, 230 volts AC circuit complete all as specified and directed. |
| 20 | S&F socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed. |
| 21 | Supply & fixing for ceiling rose, 3 phase, PVC polycarbonate, isolated body complete all as specified and directed. |
| 22 | S & F and testing LED Tube light fittings aluminium tubes 24 watts 4 feet including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Luker Cat Part No : LT5M24 or equivalent to CG/Philips Havells |
| 23 | S & F 30 watts LED building security light fittings , pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 with pranuts including necessary fixing arrangements as per site requirements class all as specified and directed by Engr In charge. Make : Luker Cart Part No: LSTE030S or equivalent to Philips /Havells/ CG |
| 24 | S & F GI brackets of GI pipe light grade of size 25 mm dia including nuts, bolts and washers for building secufity light all as specified and directed |
| 25 | S & F single pole and neutral sheet steel powder coated Distribution board IP -43 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 4 ways and making good to the distrubed surface /walls complete all as specified and directed. |
| 26 | S & F MCB SPN 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed. |
| 27 | S & F MCB SP 06-32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed .Note for item No 9.0 & 10.3:- Termination of all wiring in to MCBs/ MCCBs/DBs shall be through copper lugs/ thimbles of adequate size. |
| 28 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I |
| 29 | Excavation in trenches not exc 1.5 M deep and 1.5 M width and getting out in soft or loose soil for foundation of poles (or) cable laying. |
| 30 | Returning, filling incl spreading, levelling, watering and well ramming layers not exc 25 M for cable laying. |
| 31 | Removing/excavated soil to a distance not exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point all as specified and directed. |
| 32 | Supply, laying, testing and commissioning of underground LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 x 6 sqmm (laid in terenches,ducts,pole,wall etc.) all as specified and directed. |
| 33 | Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 40 mm (OD) x 32 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed. Please Enable Macros to View BoQ information |