| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in soft disintegrated rock, for foundation etc., or for laying of cable/ GI Pipe, shafts, wells, cesspits, manholes, pier holes, etc., complete all as specified. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in soft disintegrated rock, complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 3 | Removal of excavated material [soft rock] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 4 | M&L for Moorum/Red bajri filling brought from out side MD land including filling in floors or pavings or in foundations laid in layers n.exc. 15cm thick spread, levelled and rammed including watering, complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 5 | M&L for Hardcore of gauge not exc. 63mm, broken stone or boulders, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 6 | M&L for PCC 1:4:8 type D2 (using 40mm graded Granite stone aggregate) as in foundation, filling, mass concrete etc., complete all as specified and as directed. |
| 7 | M&L for Reinforced cement concrete M-25 Grade (Design mix) as in foundations, including footings, foundation beams, plinth beams, bases for columns, basement slabs, and mass concrete or similar items etc., complete all as specified and as directed. |
| 8 | M&L for Reinforced cement concrete M-25 Grade (Design mix) as in columns, Pillars, piers, vertical bands, posts and struts etc., complete all as specified and as directed. |
| 9 | M&L for Reinforced cement concrete M-25 Grade (Design mix) as in floor beams, roof beams, cantilevers, bressumers, middle beams, lintels over 1.5m span and lintel bands etc. |
| 10 | Steel formwork to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed. |
| 11 | Steel formwork to sides of pillars, posts, struts, columns, stanchions and the like, for fair finished surfaces of concrete, complete all as specified and as directed. |
| 12 | Steel formwork sides and soffits of floor or roof beams, cantilevers, bressummers, lintels, shelves, lintel beams, RCC bands, girders etc., for fair finished surfaces of concrete, complete all as specified and as directed. |
| 13 | M&L for Reinforcement using TMT bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 14 | M&L for Reinforcement using TMT bars of Grade Fe-500D of 8mm dia and over upto and including 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified. |
| 15 | M&L for Pre-cast cement concrete solid block masonary type C1, 1:3:6 (using 20 mm graded stone aggregate) exc 10 cm width and setting in CM 1:6, complete all as specified and as directed. |
| 16 | M&L for PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in surface channel and drain etc., complete all as specified and as directed by the Engineer-in-Charge. |
| 17 | M&L for PCC type B1 1:2:4 (using 20mm graded stone aggregate) as in cast in situ in lintels up to 1.5m span, cills, steps, seismic and other similar bands, plinth courses, parapets, copings, benching/ haunching, bed plates, bed block and the like including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and directed by Engineer-in-charge. |
| 18 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished even and fair without using extra cement complete all as specified and as directed. |
| 19 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:4 finished even and fair without using extra cement complete all as specified and as directed. |
| 20 | M&L for applying two coats of distemper acrylic emulsion paint with and including a coat of wall care putty and priming coat of alkali resistant primer, with and including preparation of newly plastered surfaces, all as per manufacturer's instructions, complete all as specified and as directed. |
| 21 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over with and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, with and including preparation of newly plastered surfaces, all as per manufacturer's instructions, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 22 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over with and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, with and including preparation of newly plastered surfaces, all as per manufacturer's instructions, complete all as specified and as directed. Please Enable Macros to View BoQ information |