| 1 | Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls ,ceiling etc including raking out joints ,hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed |
| 2 | M&L for 15mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement mixed with water proofing compound complete all as specified and directed Note: WPC will be measured and paid saperately |
| 3 | M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 4 | M&L for 10 mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | Supply only Integral waterproofing compound. |
| 6 | M&L for preparation of the newly plastered surfaces of walls & applying two coats distemper oil- emulsion , white or tinted over a coat of primer complete all as specified and directed. |
| 7 | M&L for preparation of the newly plastered surfaces of ceilings & applying two coats of White Wash complete all as specified and directed. |
| 8 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces with smart painting tools complete all as specified and directed. |
| 9 | M&L for Preparation of old surfaces by complete removal of existing treatment and applying two coats of oil bound distemper over one coat of primer on walls complete all as specified and directed |
| 10 | M & L for applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed |
| 11 | M&L for preparation of old steel painted surfaces exc 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified. |
| 12 | M&L surface preparation of old wooden surfaces of any description, not otherwise described, over 10cm width or grith and apply one coat of synthetic enamel paint complete all as specified and directed |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 14 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed or beeding layers of mortar 15mm thick in CM 1:6 in floors complete all as specified and directed. |
| 15 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat of tiles in CM (1:3) complete all as specified and directed. |
| 16 | M & L for Non skid ceramic tiles (colored), of area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or colored cement to match laid over and including screed bed or beeding layers of mortar 15mm thick in CM 1:6 in floors, complete all as specified and directed. |
| 17 | S & F coloured Glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 18 | Disamantling Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed Please Enable Macros to View BoQ information |
| 19 | Disamantling Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed Please Enable Macros to View BoQ information |