| Sl. No. | Item Description |
| 1 | Civil WorkExcavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9cum bucket capacity including cutting, trimming bottom and side slopes, in accordance withrequirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. and Earth filling under floors with surplus ordinary soil or soil containing gravel orkankar upto 40% excavated from outside the building plinth in 15 cm layers includingramming, watering and consolidating lead upto 30 metres |
| 2 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth- 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 3 | Cement Concrete 1:4:8 with stone ballast of size. Using concrete mixer volumetric type. |
| 4 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 5 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 6 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc when curved. |
| 7 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 8 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 9 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. |
| 10 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 11 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 12 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 13 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey- First Floor |
| 14 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 15 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block- For first floor |
| 16 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block- For Second floor |
| 17 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. |
| 18 | Extra for 115mm/100mm thick walls for additional storey upto 4 meters above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. |
| 19 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure |
| 20 | Extra for R.C.C/PCC. work done in each subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey-For First floor |
| 21 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted ) |
| 22 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 23 | Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey- First floor |
| 24 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.0 works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 25 | Extra for work done in each subsequent storey above the first storey for item No. 18.17, 18.18, 18.19-For first floor |
| 26 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating leadupto 30 metres |
| 27 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating leadupto 30 metres |
| 28 | Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling. |
| 29 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material |
| 30 | Conglomerate floor 40mm thick cement concrete topping 1:2:4. |
| 31 | 10mm thick Cement Plaster 1:4 |
| 32 | 12.5mm thick cement plaster 1:5. |
| 33 | 20 mm thick cement plaster 1:5 in two coats work. |
| 34 | Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level-First floor |
| 35 | Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level-Second floor |
| 36 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) |
| 37 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 38 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) |
| 39 | Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness 12mm to 15mm, Slabs sizes above 0.50 sqm |
| 40 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 41 | Extra labour for projected nosing of stair case of any shape and design. |
| 42 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 43 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 44 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position. (Code IS 2022-1(1999)). 35mm thick |
| 45 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash- welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) |
| 46 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. |
| 47 | Providing and fixing 14 gauge MS sheet garage doors with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15mm gusset plates including locking arrangement with handles etc. complete in respects |
| 48 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) |
| 49 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 50 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 51 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : |
| 52 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : |
| 53 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 54 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge 4mm thick ACP Sheet |
| 55 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) |
| 56 | Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm × 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal sash putty in steel doors, windows & ventilators complete in all respects. |
| 57 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 58 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. |
| 59 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect. |
| 60 | Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement sand mortar 1:4 and top surface to be left clear after wire brushing etc. |
| 61 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 62 | Extra for every additonal storey for flooring-For First Floor |
| 63 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 64 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 65 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item) |
| 66 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 67 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 68 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 69 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 70 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade. |
| 71 | Applying priming coat with metal primer on new steel or iron work including preparation of surface |
| 72 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 73 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 74 | Providing and fixing mineral fibre false ceiling tiles at height upto 4 Mtr. of size 595x595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 W/m K, Fire Performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80 gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main T.The system should rest on periphery walls/partitions with the help of GI perimeter wall angle of size 24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws.The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-Charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm. |
| 75 | Chil wood wrought planed and fixed in position |
| 76 | Providing and fixing commercial plywood 12mm thick |
| 77 | Providing and fixing commercial plywood 18mm thick |
| 78 | Providing and fixing ply wood, plain lining, butt jointed including PVC Plug placed at 45 cm to 65 cm centers complete with necessary nails (Frame work shall be payable extra) |
| 79 | Providing and fixing teak wood beading to door windows chowkats with iron screws fixed in position complete as per design and shape required |
| 80 | Spirit polishing two coats including a coat of wood filler on wood work |
| 81 | Earth filling under floors with surplus ordinary soil or soil containing gravel orkankar upto 40% taking outside the premises in 15 cm layers includingramming, watering and consolidated lead upto 1000 metres-(Rate amended as per subanalysis as per AC Slip-10) |
| 82 | Providing, laying, spreading and compacting stone aggregates of Grading IIto cement concrete 1:4:8 with stone blaste of size with volumemeterik tube |
| 83 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code -15568(2006). |
| 84 | Providing and laying facory made rubber moulded smooth finish cement concrete KerbM-20 grade 250mm high with bottom width 165mm anf top width 115mm made overstrong vibratory table and fixing with cemen mortar 1:2 as per MORT&H Specifications |
| 85 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete |
| 86 | Applying priming coat with cement primer in all shade on newely plastered or concrete exterior surface |
| 87 | Painting two or more coats excluding priming coat with synthetic enamel paint inall shades on wood work, metallic or plastered, concrete surface to give an evenshade. |
| 88 | Public Health work |
| 89 | Sub work-1 |
| 90 | Sub head-1 Internal Sewerage System |
| 91 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B |
| 92 | 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 93 | 75mm o/d SWR UPVC pipe lines laid complete |
| 94 | Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes |
| 95 | For 110mm o/d pipes |
| 96 | Door Cap |
| 97 | Door Elbow 90 Degree (All side socketed) door bend 110mm |
| 98 | coupler |
| 99 | For 75mm o/d pipes |
| 100 | coupler |
| 101 | P Trap/Floor Trap 75mm x 75mm |
| 102 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) |
| 103 | 110mm o/d |
| 104 | 75mm o/d |
| 105 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of |
| 106 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.450mmx600mminsidewith455mmx 610mm cover and frame light duty |
| 107 | Sub head-2 Internal Water Supply System |
| 108 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 109 | CPVC SDR 11 Pipe & fitting 16mmo/d |
| 110 | CPVC SDR 11 Pipe & fitting 20 mm o/d |
| 111 | SDR 11 CPVC pipes & fittings 25mm o/d |
| 112 | SDR 11 CPVC pipes & fittings 32 mm o/d |
| 113 | CPVC SDR 11 Pipe & fitting 40mm o/d |
| 114 | CPVC SDR 11 Pipe & fitting 50mm o/d |
| 115 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 116 | Size 75 mm x 75 mm |
| 117 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 118 | Through wall 11.43 cm thick |
| 119 | Through wall 22.86 cm thick |
| 120 | Providing, fixing and jointing CPVC Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. |
| 121 | Union 15 mm o/d complete |
| 122 | Union 20 mm o/d complete |
| 123 | Union 25 mm o/d complete |
| 124 | Union 32 mm o/d complete |
| 125 | Union 40 mm o/d complete |
| 126 | Union 50 mm o/d complete |
| 127 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 128 | 20 mm i/d Brass Ball valves |
| 129 | 32 mm i/d Brass Ball valves |
| 130 | Sub head-3 Sanitary Fixtures & CP Brass Fittings |
| 131 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI |
| 132 | Providing and fixing in position Chinawareextended wall mounted E. W.C. type suite(size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 133 | Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect. |
| 134 | Providing and fixing in position Metropole flush valve push type 32mm size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect. |
| 135 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With C.P. Brass nut |
| 136 | Providing &Fixing in position C.P. Brass Hexa Nipple 15mmofapprovedmake(tothe approvalofEngineer-in- charge)completein all respect. |
| 137 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 138 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge)consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 49 cm dia (above counter round) |
| 139 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 140 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.(Vitreous chinaware standard white pedestal for wash hand basin.) |
| 141 | PProviding & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 142 | PVC tube connection of size 15 mm x 375 mm with PTMT nut |
| 143 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 144 | Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-incharge) complete in all respect. |
| 145 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 146 | C.P. brass towel Rails size 15mm dia 610mm long |
| 147 | C.P brass towel ring |
| 148 | Providing and fixing in position paper holders of approved make (to the approval of Engineerin- charge ) fixed in to wall with C.P brass screws complete in all respect. |
| 149 | C.P. brass toilet paper holder |
| 150 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 151 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 152 | C.P. brass Bib cock long nose/ long body foam flow without flange |
| 153 | C.P. brass Bib cock foam flow without flange |
| 154 | Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge) complete in all respect |
| 155 | Providing & Fixing in postion stop cock /Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 156 | C.P.brass 15mm stop cock Male and female end |
| 157 | C.P.brass 15mm Concealed stop cock with flange. |
| 158 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 159 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long |
| 160 | Providing & Fixing in position 5mm thick bevelled edgemirror of superior glass (of approvedmake) completewith 4mm thick hardboardbacking fixed inwithrawl plugs 50 mm, C.P.brass screws and washer sand S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 450mmx600mm or any other size |
| 161 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 162 | C.P. brass Bib cock with Wall flange |
| 163 | C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body) |
| 164 | Providing and fixing in position premium range towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 165 | C.P. brass soap dish holder with glass dish |
| 166 | C.P. brass toilet roll holder with flap |
| 167 | C.P. Glass Shelf 600mm long |
| 168 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. |
| 169 | C.P. Brass khunti with 3 pegs |
| 170 | Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. |
| 171 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 172 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball32mm i/d |
| 173 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-incharge) in PVC Water storage tanks complete in all respect. |
| 174 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge For 2000 ltr Water Tank |
| 175 | Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 176 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction ofEngineer-in- charge. |
| 177 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 178 | Sub head-4 Flooring and wall tile |
| 179 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling using mechanical mixer for mixing of material |
| 180 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand)for new flooring complete . |
| 181 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 182 | ColouredGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coa rsesand)andjointedwithneatcementslurry mixedwithpigment tomatchtheshadeofstone, including rubbingandpolishing including labour for fixing dowel pins and cramps. |
| 183 | Sub head-5 Dranking Water cooler , RO ,And Air conditioning |
| 184 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) includingcarriage complete in all respect. |
| 185 | Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer |
| 186 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size |
| 187 | Automatic Voltage Stablizer 2 KVA |
| 188 | Automatic Voltage Stablizer 4 KVA |
| 189 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 190 | Supply and installing and commissioning og BEE 5 Star Split AC 1 ton of approved make (to the approval of Engineer-in-charge ) including carriage complete inall respect. |
| 191 | Supply and installing and commissioning og BEE 5 Star Split AC 1 ton of approved make (to the approval of Engineer-in-charge ) including carriage complete inall respect. |
| 192 | Supply and installing and commissioning og BEE 5 Star Split AC 2 ton of approved make (to the approval of Engineer-in-charge ) including carriage complete inall respect. |
| 193 | Providing Laying hard soft copper concealing of coper pipes of various dia as requiement and eall thickness 0.8 mm,insulated/taping laying in chase cutting of wall and repairing thr same within the buikding and chages complete in all respects. |
| 194 | For 1.0 Tonne Split |
| 195 | For 1.5 Tonne Split |
| 196 | For 2 Tonne Split |
| 197 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.Total |
| 198 | For 1.0 Tonne Split |
| 199 | For 1.5 Tonne Split |
| 200 | For 2 Tonne Split |
| 201 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 202 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 203 | Through wall 11.43 cm thick |
| 204 | Through wall 22.86 cm thick |
| 205 | Sub work-2 |
| 206 | Sub head-1 Tube Well 150 mm dia and 165 |
| 207 | Boring with casing pipe for tubewell in allsoils except ordinary hard rocks requiring blasting including removing the casing pipeafter the tube well is lowered & tested ,equipment as requried such as hand boring machine and its accessory, transportation tosite and vice versa etc. Complete in all respect. |
| 208 | Extra for boring beyond 150 mtr. Depth (CSR – 28.73) |
| 209 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. |
| 210 | 150 mmnominal diameter (weight 21.6 kg per metre) 5.4mm thickness |
| 211 | Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewellbore. |
| 212 | 150 mm Steel Strainer (slot size 0.15/0.20mm) 5.00 mmthickness |
| 213 | Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect. |
| 214 | Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plugcomplete in all respect. |
| 215 | 150mm internal diameter (weight 21.6 kg per metre) 5.4mm thickness |
| 216 | Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 217 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. |
| 218 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitablesize complete in all respect. |
| 219 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. 150 mm internal diameter |
| 220 | Supplying at site Wooden Box of suitable sizewith Lid& locking arrangment for preserving strata sample collected from the bore. |
| 221 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) |
| 222 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.Capacity of Air compressor 550 cfm at 600 PSI |
| 223 | Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-incharge |
| 224 | Collection of water sample from differentstrata and testing of sample from approved laboratory (Phisical &chemical Analysis) |
| 225 | Providing & fixing Sanitry Seal as per BIS 2800:2019 |
| 226 | Sub head-2 Pumping Machinery ,CI Fitting and Cholrinate |
| 227 | Providing & installing, testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 105 LPM against a head of 59 mtr along with electric panel board consisting of electrical appliances DOL. starter, Mainwitch, VM, AMpere Meter, ELCB, Shunt capacitor.Single phase, preventer, Indicating lamps, Kit-Kat etc, including GI column Pipe of IS 1239- 2004 medium class size 40 mm and Length41 mtr.(in 3mtr lengths each with flanges, screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 55 Mtr. Length and 2.5mm2 size as per IS694- 1990 reaffirmed 2000 complete in all respects |
| 228 | Providing and installing 80mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. Cholrinator |
| 229 | Prov. & Instaling, testing & commissioning one No Electronically actuated, Diaphram Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 liter of Bleaching Powder solution /Sodium Hypo soiution per our under maximum delivery pressure up to 7 Kg.cm 2, and suction lift not less than 1.5 m,as per DWS stanard specifications. |
| 230 | Sub head-3 Estate Water Supply system |
| 231 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets oropen area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete inall respect. |
| 232 | Including Excavation Providing, Laying , fixing & jointing of P.V.C.Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as perspecifications. 63mm o/d pipe of 6 Kgf. / sqcm |
| 233 | P/F and jointing CPVC Union couplings with UPVC pipe complete in all respect 50mm i/d CPVC Union |
| 234 | Providing & Fixiing C.I indicating plates of size 100mm x 100 mm for SV/FH including synthetic enammel paint & letters in white enamel paint, fixing in the ground with angle iron of size 25x25x5mm, 230mm height from ground including conrete block complete in all respect as directed by Engineer-in-charge |
| 235 | Sub head-1 Estate Sewerage System |
| 236 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 237 | 110mm o/d pipe |
| 238 | 160mm o/d pipe |
| 239 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths asshown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and aintenanceof caution boards, fencing, refilling trenches, watering, ramming and estoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. |
| 240 | Providing and filling sand grading as perspecifications or fine grade around thevarious sizes of G.I. pipes in external work. |
| 241 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths asshown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and aintenanceof caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. |
| 242 | Cement concrete 1:4:8 |
| 243 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 244 | Cement concrete 1:2:4 |
| 245 | Floating coat of 1:5mm thick neat cement laid in one operation to the topping |
| 246 | 12.5 mm thick cement plaster 1:3 |
| 247 | Cement rendering on plaster 1mm thick |
| 248 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 249 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 250 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 251 | Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). |
| 252 | Sub Head -2 Providing Saptic Tank 3mX2m X 1.2 mworking depth for sewer disposal. |
| 253 | Providing Saptic Tank 3mX2m X 1.2 m working depth for sewer disposal. & soak pit 2.5 m outer dia 3.0 mtr deep |
| 254 | Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. |
| 255 | Sub Work-1 Fire fighting System |
| 256 | Providing and fixing of FIRE EXTINGUISHER, ABCPowder type (stored pressure) asper IS:15683 completewithall accessories as per Manufactures Specification. ISI Mark complete in all respect.6 Kg.Capacity |
| 257 | Providing and fixing of FIRE EXTINGUISHER,CO2typeasper IS:15683 complete with all accessories as per Manufactures Specification. ISIMark complete in all respect.4.5 Kg. Capacity |
| 258 | Electrical work |
| 259 | Internal E.I. Services |
| 260 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 261 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 262 | Wiring Networking socket point RJ45 (one module) |
| 263 | Wiring fan point (With fan box) |
| 264 | Wiring light point |
| 265 | Wiring call-bell point |
| 266 | Wiring 6Amp. wall socket point |
| 267 | Wiring 6Amp. Plug control comprising wall socket point |
| 268 | Wiring 16/20Amp. power plug control point |
| 269 | Wiring light point with double control switches. |
| 270 | Overall size 1 sq.mm (Un-sheathed) |
| 271 | Overall size 1.5sq.mm (Un-sheathed) |
| 272 | Overall size 2.5sq.mm (Un-sheathed) |
| 273 | Overall size 4sq.mm (Un-sheathed) |
| 274 | Overall size 6sq.mm (Un-sheathed) |
| 275 | Overall size 10sq.mm (Un-sheathed) |
| 276 | Overall size 16sq.mm (Un-sheathed) |
| 277 | Overall size 50sq.mm (3½ Core) Un-armoured (Loose) |
| 278 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. |
| 279 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 280 | Heavy Gauge PVC Conduit pipe 40mm dia. (Flushed) |
| 281 | PVC Flexible Pipe 25mm dia. |
| 282 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 283 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 284 | Additional Length 20mm x 3mm thick Copper Tape |
| 285 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 286 | Ceiling Rose (Flush Piano type) |
| 287 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 288 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 289 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 290 | TP&N Horizontal Double Door Distribution Board 6 way each |
| 291 | TP&N Horizontal Double Door Distribution Board 8 way each |
| 292 | Cable End Box for TPN 6 Way |
| 293 | Cable End Box for TPN 8 Way |
| 294 | LT PANELS: |
| 295 | ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): |
| 296 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 297 | MCCB Four Pole 250amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 298 | Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.) |
| 299 | Aluminium thimble cable Core size 25 -35sq.mm |
| 300 | Aluminium thimble cable Core size 50sq.mm |
| 301 | Supply and erection of LED batten 10watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary |
| 302 | Supply and erection of LED batten 20watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary |
| 303 | Supply and erection of LED batten 40watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. |
| 304 | Supply and erection of Recessed mounted 12watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. |
| 305 | Supply and erection of Recessed mounted 18watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. |
| 306 | Supply and erection of LED Recessed downlighter 6watt LED (including constant LED driver) with High quality Presure die cast aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. |
| 307 | Supply and erection of Surface mounted 36/40watt LED 1x4 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers and hanging GI wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. |
| 308 | Supply and erection of Recessed mounted 36watt LED 2x2 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers and hanging GI wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. |
| 309 | Supply and erection of venti Air fan 225/230mm with aluminum louver shutter longer lift including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. The fan should confim to technical specifications attachted. |
| 310 | Supply and erection of Heavy duty Exhaust Fans 300mm 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 311 | Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee/warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 312 | Supply and erection of Wall fan 400mm Swing 16 Inch high speed including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 313 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 314 | SITC of CAT 6 24 PORT FULLY LOADED |
| 315 | Supply of CAT 6 One meter long patch cord |
| 316 | SITC of 12 U wall |
| 317 | SITC of 1kVA/800WATT |
| 318 | SITC of 24 Port POE 190+ Watts L2 managed 10/100/1000 Mbps Data switch with with 4 No Uplinks RJ45 and SFP Combo 1G Ports • IEEE 802.3u 100BASE-TX Fast Ethernet• IEEE 802.3ab 1000BASE-T Gigabit Ethernet• IEEE 802.3az Energy-Efficient Ethernet (EEE)• ANSI/IEEE 802.3 NWay auto-negotiation• IEEE 802.3x Flow Control, Standards • IEEE 802.3 10BASE-T Ethernet Switching Fabric • 50 Gbps Data Transfer Rates • Gigabit Ethernet • 2000 Mbps (full-duplex) • Fast Ethernet • 100 Mbps (half-duplex) • 200 Mbps (full-duplex)• Ethernet • 10 Mbps (half-duplex)• 20 Mbps (full-duplex), PoE Standards • IEEE 802.3af • IEEE 802.3at PoE-capable Ports • Ports 1 to 8 Power 60W • 360 W (30 W max. per PoE port). CPU RAM 256MB or above, Certification - FCC class A, CE class A, VCCI, BSMI, CCC, CE, LVD, UL, CB Oper Temp- -5 to 50 °C (23 to 122 °F) complete in all respect as desired by the engineer in charge at site. |
| 319 | CAT 6 LAN cable |
| 320 | supply installation testing & commission of 5 mp ip network |
| 321 | STC of 16 channel IP input |
| 322 | SITC 6000 GB audio video |
| 323 | sitc of smart 32'' led |
| 324 | sitc of 24 port |
| 325 | SITC of CAT 6 24 PORT FULLY LOADED |
| 326 | sitc of cat 6 one meter |
| 327 | Sitc of 10 mtr |
| 328 | PVC insulated copper overall size 1.54 sqm |
| 329 | Overall size 10sq.mm (3Core) Un-armoured (On-Surface) |
| 330 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 331 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 332 | aluminium thimble cable |
| 333 | supply and erection of led post top light 40/45 |
| 334 | Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control |
| 335 | grid interactive PV system solar power plant Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail