|
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth incl. all leads and lifts as directed by Engineer-in-Charge.All kinds of soil : |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked material :All kinds of soil : |
| 3 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil : |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade incl.curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone agg. 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½::3 (1 cement : 1½ coarse sand : 3 graded stone agg. 20 mm nominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto all level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 10 | Centering & shuttering including strutting, propping etc. and removal of form for |
| 11 | Foundations, footings, bases of columns etc. for mass concrete. |
| 12 | Suspended floors, roofs, landings, balconies and access platforms |
| 13 | Columns, pillars, piers, abutments, posts and struts. |
| 14 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 15 | Edges of slabs and breaks in floors and walls under 20 cm wide |
| 16 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth. in cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 17 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 18 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 19 | 12mm Cement plaster of mix:1: 4 ( 1 cement : 4 fine sand) |
| 20 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 21 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. |
| 22 | Supply of M.S. pipe 200 mm dia Casing pipe |
| 23 | 18mm plastering with terrazzo finish rubbed and polished complete, under layer 12mm thick cement plaster 1 :3 (1 cement : 3 coarse sand) and top layer 6mm thick white, black, chocolate, grey, yellow or Baroda green marble chips of 3mm and down size laid in cement marble powder mix 3 : 1 (3 cement : 1 marble powder) by weight in proportion 4 : 7 (4 cement marble powder mix : 7 marble chips) by volume including P/L of Chicken mesh all as specified and directed by Engineer-in-Charge. |
| 24 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using M.S. angles 40x40x6mm for diagonal braces |
| 25 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws to be paid separately). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 26 | Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S Flat 15x3 mm and nuts and bolts complete. Galvanized M.S wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 27 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0mm thick glass panes |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 29 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 30 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 31 | Rectangular shape 600x450 mm precast R.C.C. manhole cover with frame complete job all as specified and directed. |
| 32 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 33 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 34 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 35 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 36 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 37 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 38 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 12 way , Double door |
| 39 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 40 | Supplying and drawing following sizes of FRLS PVC insulated copper conducter single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 41 | 3 x 1.5 sq. mm |
| 42 | 2x 6 sq. mm |
| 43 | Supplying and fixing of twin core 16 Sq mm Aluminium cable all along the wall surface anarmoured |
| 44 | Supplying and fixing of ceiling fan of 1200mm sweep with 2.25 mfd condenser and 1'-6'' down rod including fan hook , with necessary connection from from ceiling rose to fan using twin core copper wire. (As approved by Engineer-in-charge) |
| 45 | Supplying and fixing of 300mm/ 12'' sweep exhaust fan sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible wire |
| 46 | Supplying and fixing of light fittings with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire as directed by Engineer-in-charge. |
| 47 | 20/ 22 watt LED 4 feet tube light fitting/ fixture aluminium housing with 2000 lumens and min lumens efficiency 100 lumens/watt P.F > .90 having 50000 hours |
| 48 | 9 watt LED bulb of approved quality |
| 49 | Disposal of mulba within an average lead of 1 kms |
| 50 | Carriage of sand by mechanical transport incl. loading/unloading within a lead of 05 kms |
| 51 | Carriage of stone aggregate below 40 mm by mechanical transport incl. loading /unloading within a lead of 05 kms |
| 52 | Carriage of stone aggregate above 40 mm by mechanical transport incl. loading /unloading within a lead of 05 kms Please Enable Macros to View BoQ information |