| 1 | Dimantling brick work or stone work in lime or cement mortar and including stacking or materials as directed by the Engineer-in-charge with in a distance of 60 meter (200 feet). |
| 2 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) From brick work in cement mortar. |
| 3 | Dismantling reinforced cement concrete or reinforced brick work including stacking of materials as directed by the Engineer-in-charge with in a distance of 60 meter (200 feet). |
| 4 | Scrapping old white or colourwash including disposal of refuse as directed by engineer in charge with a distance of 60 m . (SI No 708) |
| 5 | Providing Wall putty on old surface with approved quality material berger/jk/birla or similar. |
| 6 | Finishing walls with superior quality water proof cement paint/snowcem of approved make and quality on previous old painted surface with two coats to give even shade including preparing surface by the throughly cleaning and sand preparing and supply of all materials, labour and T&P etc. required for proper completion of the work. [S.I. No. 661+662] |
| 7 | Distempring 2 coat with oil bound distemper of approved brand and manufacture and required shade on previous painted surface to with an even shade over and excluding a primer coat with cement primer of approved brand and manufacture such as of British, Shalimar asian paint after throughtly brushing the surface free from mortar droppimgs and other froeign matter and also including preparing the surface even and sand prepared smooth including cost of all materials. [S.I. No. 650,651] |
| 8 | Painting 3 coat over previously painted surface with paint of superior quality on wood or steel and other metal suface with superior synthetic enamal paint of standard make brushing to give an even shade and finished and including cleaning the surface all dust and other foreign matter and scoured with wire brushes ,fine steel/wood scrapper , sand papering and knotting including coat of all and upply of all materials, labour and T&P etc. required for proper completion of work. [Ch-15 NI 3/3+4/3] |
| 9 | 12 mm thick plaster with one part cement and four part of approved coarse sand including supply of all materials labour and T&P etc. required for proper completion of the work (S.I. No. 584) |
| 10 | M-150 brick work in one cement & three coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of work. [S.I. No. 307] |
| 11 | M.S. or iron work of small sizes and section such as holding down bolts, hold fast, tie rods,grating etc. wrought to required from including of supply of steel ,bolts ,nuts ,wastage etc. and their fix. [S.I. No. 502] |
| 12 | Dismentling of door or windows including choukhat but excluding hold fast and including stacking of materialas directed by Engineer-in-chargewithin a distance of 60 meters.(200ft) S.No. 703 Ch. 17 |
| 13 | Supply and fixing of 32 mm thick commercial quality ply wood board flush shutters generally confirming to I.S. 2202 Part I (1983) including fixing of wooden cleats and stoppers, locks and including fixing and adjustment of hinges, bolts nuts handles springs and other fitting but excluding their supply and including painting with two coats of black japan on all iron fitting if necessary screws to be supplied departmentally. [S.I. No. 470(i)] |
| 14 | Supply and fixing 6 to 8 mm thick ivory or light shades vitrefied tiles 600 x600 mm size in flooring and skirting with 1:3 approved cement and coarse sand mortar finished with in its cement colour slurry, jointing and polished of approvedquality complete including supply of all materials labour tools and plants etc required for proper completion of the work. as per direction of Engineer-in-charge |
| 15 | Perforated ceiling tiles:- Providing and fixing in position perforated practice board ceiling tiles bonded with B.W.P type phenol formaldegyde synthetic rasin tiles in size 60x60x12 mm over Aluminium T-Section frame of approved size and section and suspended from the roof with the help of iron hangers of size 3.0 mm Steel wire and fastners. On under side leaving an expansion gap of 6 mm and with provision for providing necessary lighting fixtures complete as per direction given by engineer-in charge. (excluding cost of lighting fixtures) |
| 16 | Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 17 | Supply and fixingof M.S. box of size 600mm x 480mm x 200mm deep in sunk for housingBDB/TPN fabricatedfrom 16 gauge M.S. Sheet and 13mm x 2.5mm flat iron etc. painted outside with red oxide primer and inside with syntheticenamel paint complete in all respect. |
| 18 | Supply and fixing of call bell of approved make on polished MDFEG / Teak ply board including making connections etc. complete in allrespect |
| 19 | Wiring points for two ways light with 1 sq. mm.FRLSH PVC insulated multistrandsingle core copper conductor cable in heavy guage rigid steel conduit pipe on surface, complete with 14 SWG copper earth continuitywire, two ways 2 nos. piano type switches& ceilingrose/ angle/ batten holder on 3mm. thick phenolic laminated backelitesheet etc., complete in allrespect, as directed. |
| 20 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduitpipe on surface complete with 14 SWG copper earth continuitywire, piano type switch & ceilingrose on 3 mm. thick phenolic laminatedbackelite |
| 21 | Wiring point for light with 1 sq. mm.FRLSH PVC insulated multistrand singlecore copper conductor cable in heavy guage rigid steel conduit pipe on surface, complete with 14 SWG copper earth continuity wire,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. |
| 22 | S & F surface/Flush mounting 4 ways SPN distribution board with additional metal door without MCB complete in all respect, as Direct by Engineer in Charge |
| 23 | S&F of 6 Amp. to 32 Amp. 4 pole MCB (10 KA) C Curve |
| 24 | Supply and Fixing 1.5 tonn Split AC |
| 25 | Supply and Fixing Automatic Line Voltage Corrector (Stabilizer) |
| 26 | AC and Stabilizer Instalation Charges |
| 27 | Supply and Instalation of LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt 8.8.4 DSR |
| 28 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(2.20DSR) |
| 29 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.1.32(DSR) |
| 30 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).2.4.1DSR |
| 31 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(1.14.10) |
| 32 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(1.14.2) |
| 33 | MCB 63 Amp 4 Pole MCB |
| 34 | Industrail Soccket 8-40 Amp DPMCB |
| 35 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(2.10.1 DSR) |
| 36 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(11.1.20 DSR) |
| 37 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Please Enable Macros to View BoQ information |