| 1 | M&L Rendering 15mm thick in cement mortar (1:4) on fair face of brick work, or concrete surfaces finished fair and even with out using extra cement with WPC @ 1%, upto 10 metre height including necessary scaffolding and taking down cement plaster and racking out joints, hacking for key scrubbing down with water etc, complete all specified and directed by Engr-in-Charge. Note :- WPC shall be measured and paid separetely. |
| 2 | M&L for Rough cast plaster including After applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick with WPC@1% and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. The mix of cement and sand shall be made slightly better than normal for rendering to ensure that larger aggregates are thoroughly covered complete all as specified and directed, including taking down cement plaster and racking out joints, hacking for key scrubbing down with water etc complete all specified and directed by Engr-in-Charge Note :- WPC shall be measured and paid separetely. |
| 3 | Supply only integral Water Proofing Compound as per manufacturer instructions complete all as specified. |
| 4 | M&L for Preparation of new plastered /un plastered Wall surface and applying two coats of cement base paint over priming coat, complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L for preparation of new plaster/un treated surface of wall / coloum, beam, chajja etc. and leveling / edgesing the disturbed surface a thin layer of putty and making smooth by using sand paper applying two coat of exterior acrylic emulsion (weather proof treatment) including one coat of exterior primer, to be applied using an airless spray machine, complete all as manufacturer's instruction and as directed. |
| 6 | M&L for Preparation of old plastered /un plastered Wall surface and applying one coat of cement base paint, complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L Rendering 15mm thick on brick surfaces of wall in cement mortar (1:6), finished even and smooth without using extra cement, including taking down cement plaster and racking out joints, hacking for key scrubbing down with water etc, complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for applying 2 mm thick wall care putty (internal or external ) on wall new or old surfaces complete all as specified and directed by Engr- in- Charge. |
| 9 | M&L preparation of new plaster surfaces and applying two coat of oil bound distemper white or tinted complete,to be applied using an airless spray machine over a coat of primer all as specified and directed by Engr-in-Charge. |
| 10 | M&L for prepration of old surface of wall and applying one coat of oil bound distemper white or tinted, to be applied using an airless spray machine, complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L Rendering 10mm thick on brick surfaces of ceiling, chajja portions etc in cement mortar (1:3), finished even and smooth without using extra cement, including taking down cement plaster and racking out joints, hacking for key scrubbing down with water etc .complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L prepration of new surface of ceiling and applying two coat of oil bound distemper over a coat of primer white or tinted complete all as specifeid and directed by Engr-in-Charge. |
| 13 | S&F GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specifeid and directed by Engr-in-Charge. |
| 14 | M&L prepration of old surface of ceiling and applying one coat of White Wash complete all as specifeid and directed by Engr-in-Charge. |
| 15 | M&L Preparation of old wood or wood based surfaces over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge. |
| 16 | M&L Preparation of old steel or iron surfaces over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specifeid and directed by Engr-in-Charge. |
| 17 | Hacking out old broken glass (any thickness) from wooden/steel frames, glazed with putty of fixed with screws complete all as specified & directed by Engr-in-Charge. |
| 18 | S&F Glass Sheet plain glass 4 mm thick, glazing with oil putty / 10 mm hollow square section welded or fixed with screwes in square not exceeding 0.5 Sqm in each pane at height up to three story bldg incl necessary scaffolding complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for complete removal of existing treatment by scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having sanding pad of diameter of 7'/9' using a 80 grit sand paper to make the surface free from dust, loose paint etc. by skilled labour complete all as specified and directed. |
| 20 | M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additives, with heat reflectant property which can reduce the painted surface temp, by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1L/6sq mtr diluted with water as per manufacturer instructions applied including one coat of acrylic water based exterior grade primer @ 1L/11 sq. mtr diluted with water in 1:1 ratio to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI & including a coat of external 2mm putty Allow 6-8 hrs to dry the surface in both the coats of paint, at any height, complete all as specified directed. |
| 21 | M&L for removal of paint/putty etc from the wall using mechanical means as per manufacturer instructions. Hacking of existing plastered surfaces upto 2mm. Note :- The wall treatment shall be done on hacked/new cementous surface for proper bonding & requisite results. Surface to be treated shall be passed by Engr-in-Charge. (a) Take Poly plastic fibre/ Eazee coat Ultra adhesive and white cement in equal proportion & add 25% H2O in it to make the mix as per manufacturer instructions. Apply 2 coats of wall bind adhesive mixture to the wall using a roller & brush.(b) Final & top coat apply with mixing ratio of poly plastic fibre/ Eazee coat Ultra top coat & water & white cement as per manufacturer instructions. Note :- The poly fibre plastic/ Eazee Coat Ultra should have following characterstics :-(a) Resists positive hydrostatic presure of upto 14 bars.(b) Crack filling ability upto 45 mm.(c) Temp control upto 14 degree celcious on any surface like concrete roof, metal shed & for walls also.(d) High durablity to water, fire & UV rays covering climate condition to + 55 degree celcious.Make : Nerolac Perma/ European Paints & Chemicals/ Ever Paint. Note:- The wall treatment shall be done on wall tile/new cementous/concrete surface for proper bonding & requisite results. Surface to be treated shall be passed by Engr-in-Charge. |
| 22 | Clearing of tree branches not exc 15 cm girth and cutting of trunk portion protuding over wall surface/roof surface/terrace of building of height up to 10.0 metre. Including necessary scaffolding and necessary safety measure if required and make good the surface in cement mortar (1:3) and applying one coat of anti growth of vegitation chemical as directed by Engr-in-Charge and removing of unserviceable material out side MD land and cleaning site, complete all as specified and directed by Engr-in-Charge. |
| 23 | Writing letters or figure (Blocks, Roman, Italic or Indian of size 15 cms height, 15mm wide tape, 4-5 letters per Tile base, using Reflective sheets/ tapes of Black colour, including plain white coloured tiles of size 300 x 300 mm over vertical surface, over 10 mm thick rendering in CM 1:3, also roughening of existing surface & making good the disturbed portion, complete all as specified. Please Enable Macros to View BoQ information |