| 1 | SCHEDULE `A` PART- II TO PART V (PREPRICED BY MES) Note:- These schedule are prepriced by MES and prepriced rate indicated under Col-5 bidders to quote their rate under Col-6 only. |
| 2 | Sch 'A' Part-I (Building Works) (Lumpsum price workout by the contractor for Sch'A' Part-I (building works) as per the drawings and specification Ref List of drawingas particular specification |
| 3 | Total amount of Sch 'A' Part-II (Site Clearance) (Ref pre priced Schedule attached seperately) |
| 4 | Total amount of Sch 'A' Part III (Internal Water Supply) (Ref pre priced Schedule attached seperately) |
| 5 | Total amount of Sch 'A' Part IV (Internal Electric Supply) (Ref pre priced Schedule attached seperately) |
| 6 | Total amount of Sch 'A' Part V (Road/ Path/ Culvert) (Ref pre priced Schedule attached seperately) |
| 7 | Total amount of Sch 'A' Part VI (External water supply) (Ref pre priced Schedule attached seperately) |
| 8 | Total amount of Sch 'A' Part VII (External Electric supply) (Ref pre priced Schedule attached seperately) |
| 9 | Total amount of Sch 'A' Part VIII (Sewage Disposal) (Ref pre priced Schedule attached seperately) |
| 10 | Schedule ‘A’ Part-IX (Miscellaneous Items) Note: This schedule is not pre-priced by MES and the prepriced rate indicated as \\"0.00\\" under Col 5 signifies this fact only. |
| 11 | S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 including taking down old DBs all as specified.NOTE :-(a) MCBs/MCCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 12 | S&F in repair surface mounting LED Batten 20W LED light. Fixture should have minimum efficacy at system level >=100 lumens/Watt, life of fixture not less than 50K Hrs,CCT 4000-6500K & CRI>80, PF≥0.90. An operating voltage Range of 140-270V including all connection upto ceiling rose complete all as specified and directed. |
| 13 | S&F of LED light fitting 1x 10W, 220V, AC decorative box type with driver, holder, fixture should have minimum efficacy at system level >=100 lumens/Watt, CCT 4000-6500K ,PF>0.90 including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 14 | M&L for Decorative wall light fitting made up of Polycarbonate,B-22 complete all as specified and directed. |
| 15 | S&F LED Lamp of wattage 09 Watt, 90 lm/W, with PF >0.9 & CRI:80,protection againt high voltage upto 360 V, B22 ,230 Volts,50 Hz,6500K complete all as specified and directed. |
| 16 | M&L for modular AC Box with 20A SP mini MCB, plastic enclosure & unbreakable Heavy Duty ISI mark Plug top complete for AC & geyser point set dully concealed in wall complete all as specified and directed. |
| 17 | Supply, installing, testing and commissioning in replacement of factory made and tested CPRI approved LT Panel board, Out door type, capnoy headed, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 240 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, powder coated finish front/back opening type, with aprons for cable entry from bottom, and fixing 2 Nos. danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed fromt and back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement (including provn of 65mm Godrej(Freedom)) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 30 cm above th nearest ground level complete all as specified and directed including connections of all outgoing / incoming existing cables of size 16 to 400 Sqmm and comprising of the following :-INCOMING :-(i) MCCB 4 pole, LT 415 Volts, 50 HZ AC grade of 160 Amps rating 36 KA rupturing capacity with adjustable Thermal and Maganetic setting release-01 Nos(ii) Digital Voltmeter 0-500 volts, square, 96mm, flush pattern with 3 way selector switch-01 No Make : SECURE/L&T(iii) Digital Ammeter 86mmx96mm, flush pattern with 3 way selector switch -01 No Make : SECURE/L&T(iv) 3 Nos of CTs of ratio 160/5 copper wound, Class 1.0, 10 VA-1 Set (Make BCH/SIEMENS/L&T)(v) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set (Make BCH/SIEMENS/L&T)(vi) Aluminium bus bar of rating 240 Amp-set of four OUTGOING :-(I) mccb 4 POLE, lt 415 Volts, 50 HZ AC grade of 40 Amps rating 16 KA rupturing capacity with adjustable Thermal and Magnetic setting releases-06 Nos |
| 18 | Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of HDPE pipe 40 to 100 mm bore and making good both ends all specified and directed. |
| 19 | M&L for 150mm nominal size (DWCPE) Double wall corrugated polyethylene pipe (SN8) including all fixing accessories or fittings like socket/spigot joints with elastomeric sealing ring, rubber ring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and as direcetd. |
| 20 | S&F factory made SFRC manhole covers and frame medium duty of overall size 9000mmx450mmx80mm thick factory made and test load 10 tonnes (MD-10), strength including necessary reinforcement as per IS : 1726-1991 complete all as specified and as directed. Please Enable Macros to View BoQ information |