| 1 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Group C |
| 4 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulatedcopper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 7 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 10 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 11 | 5 x 4 sq. mm |
| 12 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 13 | 32 mm |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 15 | 5/6 A switch |
| 16 | 15/16 A switch |
| 17 | 3 pin 5/6 A socket outlet |
| 18 | 6 pin 15/16 A socket outlet |
| 19 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 20 | 3 Module (100 mmX75 mm) |
| 21 | 6 Module (200 mmX75 mm) |
| 22 | 8 Module (125 mmX125 mm) |
| 23 | 12 Module (200 mmX150 mm) |
| 24 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 25 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 26 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 27 | Group C |
| 28 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 29 | 150 A, 16 kA,TPMCCB |
| 30 | 100 A, 30kA, FPMCCB |
| 31 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 32 | 12 way, Double door |
| 33 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 34 | 6 way (4 + 18), Double door |
| 35 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 36 | 4 way (4 + 12), Double door |
| 37 | 8 way (4 + 24), Double door |
| 38 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 39 | Single pole |
| 40 | Triple pole |
| 41 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 42 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 43 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 44 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 45 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 46 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 47 | For 6 way, Double door TPN MCBDB |
| 48 | Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 49 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 50 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 51 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 52 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. |
| 53 | Upto 35 sq. mm |
| 54 | Above 35 sq. mm and upto 95 sq. mm |
| 55 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. |
| 56 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 57 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 58 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 59 | 3 X 10 sq. mm (22mm) |
| 60 | 4 X 16 sq. mm (28mm) |
| 61 | 4 X 25 sq. mm (28mm) |
| 62 | 4 X 35 sq. mm (32mm) |
| 63 | 4 X 50 sq. mm (35 mm) |
| 64 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 65 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 66 | Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable1.1KV Grade Conforming to IS-7098 of size 3X10 Sq. mm. |
| 67 | Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4X16 Sq. mm. |
| 68 | Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4X25 Sq. mm. |
| 69 | Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4X35 Sq. mm. |
| 70 | Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4X50 Sq. mm. |
| 71 | Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable1.1KV Grade Conforming to IS-7098 of size 3.5X70 Sq. mm. |
| 72 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 73 | 18- 22 Watt |
| 74 | Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 75 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 76 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 77 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 78 | 36 watt |
| 79 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 80 | 50 watt |
| 81 | 100 watt |
| 82 | 250 watt |
| 83 | S/I/T/C of LED High Bay Flood Light 100 watt IP66 robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy ≥ 150 lm/W including all accessories for mounting/fixing and connection of highbay lights as per site requirement. |
| 84 | S/I/T/C of 600mm Industrial Wall fan 1440 RPM single phase including all accessories for mounting/fixing and connection of fans as per site requrement. |
| 85 | S/I/T/C of 380mm Exhaust fan heavy duty 1400 RPM single phase |
| 86 | Supplying, fixing and Installing of 63A TPN rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Three poles and Neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 87 | Supplying, fixing and Installing of 63A PN rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Three poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 88 | Supply of sewage submersible pump, 5.5 hp, three phase, 415 volts, 100mm outlet size. |
| 89 | S/I/T/C of three phase submersible pump controllers (with single phase preventer) for three phase 5Hp, 3.7KW rating |
| 90 | Supply of 3 core 6Sq. mm. flat cable for submersible pump motor |
| 91 | Supply of suction pipe 100 mm or as per site requirement |
| 92 | Supply of suction pipe 65 mm or as per site requirement |
| 93 | Supply of suction pipe 50 mm or as per site requirement |
| 94 | Installation and commissioning of sewer motor in sewer tank with all required accessories like safety/hanging wire, clamp, etc. for connection of suction pipe and hanging angle provision of motor in tank as per site requirement. |
| 95 | Supply of Openwell Submercible Pump, 3 HP, 3 Phase. |
| 96 | S/I/T/C of three phase 3HP submercible pump Controllers (with single phase preventer) |
| 97 | S/I/T/C of three phase 10 HP Fully Automatic Star Delta Starters for Heavy Duty submersible pump |
| 98 | SITC of LT Distribution Panel 1 (For Admin Building)A. Incomer1. 250A FP MCCB 25 KA with TM based release for O/C+S/C - 12. Extended Rotary handle - 13. Spreaders *(Set Of 8) 4P - 14. Digital Voltmeter , Accuracy Cl1.0, Aux Supply: 50-300Vac WithInbuilt Selector Switch -1 5. Digital Ammeter , Accuracy Cl1.0, Aux Supply: 50-300Vac WithInbuilt Selector Switch -1 6. RYB Indicating Lamps 230 VAC - 37. 250/5A, 5 VA, class-1 CTs for Metering - 38. CT Shorting Terminal - 49. 32A Nutral Link - 110. 6A SP, MCB, 10kA , \\"C\\" Curve - 3B. Outgoing1. 200A FP MCCB1.1 200A FP MCCB 25 KA with TM based release for O/C+S/C - 21.2 Extended Rotary handle - 11.3 Spreaders *(Set Of 8) 4P - 12. 125A FP MCCB2.1 125A FP MCCB 25 KA with TM based release for O/C+S/C - 22.2 Extended Rotary handle - 13.3 Spreaders *(Set Of 8) 4P - 13. 100A FP MCCB3.1 125A FP MCCB 25 KA with TM based release for O/C+S/C - 23.2 Extended Rotary handle - 13.3 Spreaders *(Set Of 8) 4P - 14. 63A FP MCCB4.1 125A FP MCCB 25 KA with TM based release for O/C+S/C - 24.2 Extended Rotary handle - 14.3 Spreaders *(Set Of 8) 4P - 15. Panel Enclosure Non Compartmentalised single Front, Fixed TypeFloor Mounting fabricated from 2.0/1.6 mm thick CRCA sheet6. Al. Bus bar 300A |
| 99 | SITC of LT Distribution Panel 2 (for Workshop)A. Incomer1. 250A FP MCCB 25 KA with TM based release for O/C+S/C - 12. Extended Rotary handle - 13. Spreaders *(Set Of 8) 4P - 14. Digital Voltmeter , Accuracy Cl1.0, Aux Supply: 50-300Vac WithInbuilt Selector Switch -1 5. Digital Ammeter , Accuracy Cl1.0, Aux Supply: 50-300Vac WithInbuilt Selector Switch -1 6. RYB Indicating Lamps 230 VAC - 37. 250/5A, 5 VA, class-1 CTs for Metering - 38. CT Shorting Terminal - 49. 32A Nutral Link - 110. 6A SP, MCB, 10kA , \\"C\\" Curve - 3B. Outgoing1. 125A FP MCCB1.1 125A FP MCCB 25 KA with TM based release for O/C+S/C - 21.2 Extended Rotary handle - 11.3 Spreaders *(Set Of 8) 4P - 12. 100A FP MCCB2.1 125A FP MCCB 25 KA with TM based release for O/C+S/C - 22.2 Extended Rotary handle - 12.3 Spreaders *(Set Of 8) 4P - 13. 63A FP MCCB3.1 125A FP MCCB 25 KA with TM based release for O/C+S/C - 43.2 Extended Rotary handle - 13.3 Spreaders *(Set Of 8) 4P - 14. Panel Enclosure Non Compartmentalised single Front, Fixed TypeFloor Mounting fabricated from 2.0/1.6 mm thick CRCA sheet5. Al. Busbar 300A |
| 100 | Dismentling and installation of LT Panel in Admin Block / workshop including removal of MCCB's from old panel, removal and refixing of the end termination of incomer and various out going cable including civil foundation. |
| 101 | Dismentling work of all old defective electrical installtions (including cable, DB, wiring etc). |
| 102 | Salvage value of old defective ceiling fan |
| 103 | (+) Add prevailing cost index @ 31.27% On DSR-2016 Amount S no. 1 to 36.1 i.e. : |
| 104 | (-)@9.5% below on (DSR-2016 Rate+Add prevailing cost index @ 31.27%) on : Please Enable Macros to View BoQ information |