Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. |
| 2 | M&L for machine cut kota stone slab flooring 15-20 mm thick for staircase step(treads/skirting) in single piece(of length not less then 1000 mm) laid over and including 15mm thick (average thickness) cement mortar (1:6)screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete ,including provn of two nos 3x3mm grooves at tread of each step complete all specified. |
| 3 | M&L for machine cut kota stone slab flooring 15-20 mm thick over 15mm thick cement screed bed using cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing(mirror finish) complete all as specified. |
| 4 | M&L for machine cut kota stone riser/skirting 15-20 mm thick over 15mm thick rendering using cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and beewax polishing complete. |
| 5 | M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match as in floor complete all as specified and directed. |
| 6 | M & L for glazed ceramic coloured tiles 300X 450 X 7 mm thick as on vertical surfaces of wall such as skirting, dado, riser etc. in Bath, WC and Kitchen set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile, including 10mm thick rendering in CM (1:4) approved by Engr-in-Charge, complete all as specified and directed. |
| 7 | S&F Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing , anodised aluminium snap beading,screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangements including taking down of old existing steel ventilator and making good disturbed surface of wall complete all as specified and as directed. |
| 8 | S&F Powder coated aluminium window sliding type three track (2 glazed & one gauze shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of wall complete all as specified and as directed. |
| 9 | M&L for mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as Specified. |
| 10 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprisin of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) all as spd and as directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 11 | S& F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 andresistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved designpasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of requiredsize with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 12 | M & L for providing & fixing factory made solid PVC cup board/ cabinet shutter (Flush type) of 24 mm thick made from co-extruded 3 layer regid PVC foam sheet (single extruded) with density not less than 600kg/cbm outer layer (.8-1mm) thick should be of rigid PVC with density of not less than 1400kg/cbm manufactured byan ISO 9001-2015 certfied company. Door should be water proof, turmite proof, fire retardant and having good screw holding capacity complete all as specified and directed. |
| 13 | M&L for providing and fixing factory made PVC shelf/partitation of required size consisting of 20mm thick solid PVC sandwich panel with 1mm thick plain PVC sheet on both sides suitably fixed in complete all as specified and directed |
| 14 | S&F for factory made 35mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitred beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 clause No.8.23(a) and fitted to chowkats complete all as specified and as directed. |
| 15 | M&L 15mm thick ready mix plaster on brick work on concrete surface of wall surfaces finished even and smooth including taking down all as specified and directed by GE. |
| 16 | M&L 5mm thick ready mix plaster on ceilling surfaces finished even and smooth including taking down all as specified and directed by GE. |
| 17 | M&L for preparation new internal wall surfaces with one coat wall putty and applying two coats of distemper acrylic emulsion over one coat of primer complete all as specified and directed . |
| 18 | M&L for two coats of acrylic distemper over one coat 1 mm thick wall putty on old surface of wall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots |
| 19 | M&L for for preparation of newly ceiling plastered surfaces and applying three coats of white wash as specified as diracted. |
| 20 | M&L for preparartion of old surfaces of ceiling applying two coat of white washing complete all as specified and directed. |
| 21 | M&L for preparation of new surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 22 | M&L for complete removal of existing treatment and preparation of old surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 23 | M&L for preparation of old decorative surface of wall and applying two coat of of colour/white wash to match the colour of existing surface all as specified as diracted. |
| 24 | M&L for washing, rubbing down and scraping of old decorated surface and preparation of old ceiling plastered surfaces for applying one coats of white wash on wall as specified as diracted. |
| 25 | Removing and Hacking of existing deteriorated damaged & loose concrete from the external surface of the structure carefully by low impact high frequency hammer or by manual chipping without damaging the existing concrete or control sand blasting including cleaning the surfaces by air jet etc, complete and also without damaging the existing structure.The rate shall also include disposal of waste/rubble/malwa from site outside MD Land upto as directed by the Engr-in-Charge along with lead and lift if any including standard steel scaffolding upto a height of 7 M.Note : The above treatment will be done in presence of company authorised person and also company skilled workers |
| 26 | S&F Wire netting of galvanised steel wire 1.40mm dia Size of mesh in mm 25mm fixed with tinned tacks,wall,column etc with wire staples complete |
| 27 | Patch Repair Work : M&L for 25 mm thick(Avg Thickness) Guniting concrete surface using mechanical means with single component,shrinkage controlled,polymer modified,fiber reinforced structure grade cementious repair mortar having compressive strngth of 45 N/sqmm,flexural strength of 7 N/sqmm and tensile strength of 2.5 N/sqmm at 28 days all as per the diraction of Engr-in-Charge including standard steel scaffolding up to a height of 7M Note:The above treatment will be done in presence of company authorised person and also company skilled labour. |
| 28 | Demolition of cement concrete (un-reinforced ) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) all as specified and as directed. |
| 29 | M & L 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded aggregate) for levelling course in floors complete all as specified and directed. |
| 30 | M&L 75 mm thick PCC 1:4:8 type D2 (Using 40 mm graded stone aggregate) as in sub base of floors as in levelling course finished even and rough complete for floor below tilesall as specified and directed. |
| 31 | Demolition of brickwork built in cement mortar including all quions, arches, pillars etc complete all as specified and as directed. |
| 32 | M&L brick work in CM ( 1:4 ) with using sub class `B ` modular brick straight or curved on plan exceeding 6.0mtr mean radius complete all as specified and directed. |
| 33 | Brickwork with subclass `B' bricks, straight or curved on plan exc mean radius built in cement mortar 1:4 complete as directed (Except brick) |
| 34 | Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed . |
| 35 | M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC in order to maintain proper slope over existing roof surfaces for laying APP base plymeric membrane, finished even and smooth without using extra cement complete all as speified and as directed. |
| 36 | M&L for providing, cement concrete type B1 1:2:4 using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges, padding to roof etc complete |
| 37 | M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints and Dusting dry sand @ 0.75 Kg per Sqm and applying two coat of bituminous aluminium paint @ 0.10 Kg/Sqm over the membrane. |
| 38 | Taking down chowkaths or frames Exc 1.5 sqm but n.exc 4 sqm (without taking off shutter from the frame) each and removing from the site including dismantling brick work for hold fasts etc complete all as specified. |
| 39 | Taking down chowkaths or frames n.exc 1.5 sqm (without takingoff shutter from the frame) each and removing from the site including dismantling brick work for hold fasts etc complete all as specified. |
| 40 | M&L for PCC type C-1, 1:3:6 using 20mm graded aggregate as in bed block for fixing of hold fast, filling concrete in frame filling , gaps in between glazed & flyfproof steel window, cills, railling up to 60 cm in height etc including necessary form work as required all complete. |
| 41 | S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour printed PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing |
| 42 | S& F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification with Wood free EPS complete all as Specified. |
| 43 | S&F of SS butt hinges, medium weight cold rolled of size 100mm complete all as specified and as directed. |
| 44 | S&F 150 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified . |
| 45 | S&F 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified . |
| 46 | Supply & fixing aluminium anodised extruded fabricated type handle 150mm long complete all as specified. |
| 47 | S&F Aluminium alloy anodised sliding door bolt 250 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified . |
| 48 | S&F door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified . |
| 49 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as Specified. |
| 50 | M&L Framed work as in doors or gates of angle or other section with gusset plates, balusters, hand rails, including cleats, brackets,braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 51 | M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 52 | S&F stainles steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm |
| 53 | Material & labour for 75 mm thick PCC (1:3:6) Type C-2 (20 mm graded aggregate) as in plinth protection incl finishing the concrete surface even and smooth w/o using extra cement complete all as specified.(Note: The unit rate quoted shall be deemed to include for providing the concrete in alternate bays n exc 3 mtr long with 12 mm wide and 50 mm deep joint between the bays which shall be filled with mastic filling with hot bitumen 85/25 and 1:2 mix by volume.) |
| 54 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete all as specified. |
| 55 | Supply, laying and fixing of 20mm outer dia of CPVC pipe SDR 11 and plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete including brass CPVC fittings (i.e elbow, Tee, MTA/MBTA,FTA/FBTA, Tank adaptor, Union, etc suitable for 15mm bore bath fittings). (Note- length of pipe with fittings to be measured for payment, no extra payment should be made for fittings). |
| 56 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing etc., and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified. |
| 57 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified. |
| 58 | S&F of Tubes, medium grade, 20 mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified. |
| 59 | Refixing old steel tubing 20mm dia and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified. |
| 60 | Dismantling water tank exc 250 & n.exc 1000 ltr capacity and removing to store complete all as specified. |
| 61 | Supplying & fixing of PVC water storage tank 1000 ltr capacity HDPE double layered , cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection incl locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight 20 mm - 210 gms ) . Note : (i) GI inlet, outlet & wash out pipe will be measured paid for separately. |
| 62 | S&F in repairs 15 mm dia Bib tap Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed . |
| 63 | S & F in repair consealed stop cock CP, cast copper alloy fancy type with long shank and cup for 15mm pipe complete all as specified. |
| 64 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm |
| 65 | S&F in repair 15mm bore CP Stop cock of any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms). |
| 66 | S&F in repairs of CP swivel shower of any coloured for fixing with 15mm pipe (Minimum weight 40 gms) |
| 67 | S & F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including CP waste coupling, waste pipe & removing the existing Basin, cutting for and pinning ends of brackets or erecting stand. |
| 68 | Supply and Fix in repairs 15 mm bore pillar taps, capstan head, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 69 | S&F beveled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified. |
| 70 | S&F vitreous china squatting pan\\"Orissa\\" pattern size 580x440mm white with intgeral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S\\" trap fron or back inlet etc including connection to trap tand flushing pipe and provision of lime concrete bedding complete all as specified and as directed in repairs including demolition of existing one |
| 71 | Supply & fixing in repair PVC low level dual flushing cistern 10 ltr capacity sleek having weight not less than 1.80 KG including PVC bend, supporting brackets and complete accessories white colour complete all as specified & directed. |
| 72 | S & F grating doom 125mm dia with waste hole of CP (min wt 40 gms) |
| 73 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) |
| 74 | S&F 110 mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floors complete all as specified. |
| 75 | S&F 75 mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floors complete all as specified. |
| 76 | S&F 110mm dia PVC SWR bends of any radius with out access door complete all as specified and as directed |
| 77 | S&F 110mm dia PVC (SWR) junction single 'T' equal or unequal with access door Complete all as specified and as directed. |
| 78 | Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete |
| 79 | M&L for point wiring with 1.5 Sq.mm (nominal size) single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable confirming to IS 694:2010 with and including continuous earth wire of size 1.5 Sqmm (nominal size) single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353: 1985 drawan through and including rigid non-metallic PVC concealed conduit of 20mm dia (Nominal bore) or higher, medium grade confirming to IS 9537(Part 3): 1983 complete with and including all PVC conduit accessories and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM confirming to IS 14772 : 2000 having op, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover plate with frame and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732: 2019 and directed by Engr-in-Charge, for One light / bell point controlled by one, one way switch 06 Amps, complete all as specified and directed. |
| 80 | All as per above Item No 79 here-in-before but one Ceiling / exhaust fan point controlled by one, one way switch 5/6 Amps |
| 81 | All as per above Item No 79 here-in-before but one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, one way 06 Amps switch |
| 82 | All as per above Item No 79 here-in-before but one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch |
| 83 | All as per above Item No 79 here-in-before but one 3 pin, 15 Amps socket outlet point on independent board 2.5 sqmm nominal cross sectional area controlled by one, one way 15 Amps switch |
| 84 | S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed |
| 85 | S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete |
| 86 | S&F modular socket outlet 3 Pin, 06 Amps, 02 module with shutter complete |
| 87 | S&F modular socket outlet 02 in 01, 3 pin, 6/16 Amps, 02 module with shutter complete |
| 88 | S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete |
| 89 | S&F surface mounting LED integrated aluminium housing batten with polycarbonate deffuser luminaire not less than 22 W, 4 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 2.5 KV, CCT 5700K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete. |
| 90 | Supply and fixing wall mounted fan of 400 mm sweep, 230 volts, AC, 50 Hz capacity, including all arrangements for mounting of fan including connecting up with provision of PVC insulated flexible twisted type copper conductor cable 1.5 Sqmm, 2 core as required for connections complete all as pecified and as directed. |
| 91 | S&F surface mounted LED building security light fitting in high pressure die cast aluminium housing not less than 45 watt fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V including light grade GI tube mounting size 40MM bracket of suitable size & length, bend to shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete and one coat of primer and one coat of synthetic enamel paint after coating of primer on GI bracket and pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core complete all as specified and as directed. |
| 92 | Supply, Installation, Testing and Commissioning in repair of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete and taking down old/unsv fan and deposit in E/M store yard complete all as specified and directed. |
| 93 | M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed. |
| 94 | All as in above item 97 but with 2 X 4 Sqmm for Phase & Neutral and 1 X 4 Sqmm for earth complete all as specified & directed. |
| 95 | S&F sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and sheet metal enclosure double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Note - (a) MCB shall be measured and paid seprately under respectively item. (b) Make for the DB/MCB/MCCB shall be same.) |
| 96 | Supply and fix in repair electric water heater, storage type 25 ltrs capacity, BEE star rated, vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode having adustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minium two year warranty on product, minimum three years on heating element complete all as specified and as directed. (Note : Taking down Old/ unsv Geysers and deposited in MES store). |
| 97 | S&F Ventilating fan, wall mounted type of 250 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frame/all required arrangement for mounting of fan including making good of disturbed surface. |
| 98 | Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning by using suitable copper lugs complete:- |
| 99 | (a) SP 6 To 32 AMP |
| 100 | (b) SPN 40 to 63 AMP |
| 101 | S&F Industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB SP, AC, 230 volts of 20 Amps, 'B' curve 10 KA breaking capacity for geyser and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete |
| 102 | Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 50 sqmm 3.5 core nominal cross section complete |
| 103 | Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in soft soil & getting out including levelling of bottom surface to required level complete |
| 104 | Returning filling , including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete |
| 105 | Removing excavated material /soil from site to a distance not exc 50mtr away and depositing where directed and level not exc 1.5mtr from the starting point complete |
| 106 | Sub class ‘B bricks, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and as directed |
| 107 | Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed. |
| 108 | M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete.(Note: Earth test shall be C/O in presence of Engr-in- Charge as per latest guidelines of earthing,On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.) |
| 109 | S&F Rotating search LED light fitting in high pressure die cast aluminium housing not less than 150 watt fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V with and including all arrangments for rotating 360 degree with and including all PCC work, fabrication ,wellding and painting etc ,GI pipe Medium grade of size 40mm etc complete and one coat of primer and one coat of synthetic enamel paint after coating of primer on GI bracket and pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core complete all as specified and as directed. |
| 110 | Taking down old unsv fan of any type/size and depositing in AGE E/M store yard complete all as directed by Engr-in-Charge |
| 111 | Taking down old unsv submain wiring of any size and type complete all as specified and directed |
| 112 | Taking down old unsv DB including MCB/SPN enclosure any type / size complete all as specified and directed Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |