| 1 | Taking down Cement plaster or cement lime plaster on brick or stone walls including raking out joints, hacking for key & scrubbing down with water etc complete including disposal of unserviceable rubbish outside cantt area all as specified and directed by Engineer-in-Charge. |
| 2 | Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., and removal from site complete all as specified and directed by Engineer-in-Charge. |
| 3 | Demolition of brick work or stone/boulder masonary built in cement mortar incl all quions arches, pillar or any other descrption etc complete including disposal of unserviceable rubbish outside cantt area all as specified and directed by Engineer-in-Charge. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. |
| 5 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc, complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. |
| 6 | Hacking out old broken glass (any thickness, size, quality or description) from metal/ wooden frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed by Engr-In-Charge. |
| 7 | Repairing the edges of concrete chajjas, facias, slabs, columns & the like by providing PCC (1:2:4) type B-0 including all necessary form work and rendering 15 mm thick (average thickness) in cement mortar (1:3), after applying a coat of cement slurry @ 3 kg/ Sq. m of surface, finished even and fair, surface area not exceeding 450 mm wide, in patches including taking down swoolen/damaged plaster or concrete complete all as specified. |
| 8 | Rendering 5 mm thick in cement mortar 1:3 as in ceiling/soffits of slabs/Chajja/ Sunshade finishing the plastered surface even & smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge. |
| 9 | Rendering 15 mm thick in cement mortar 1:6, on other than fair faces of brickwork or concrete surfaces finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Rendering 15 mm thick in cement mortar 1:4 on on fair faces of brick or concrete surfaces etc mixed with water proofing compound finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.NOTE: Water proofing compound shall be measured and paid separately. |
| 11 | Brick work with sub class 'B' bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 12 | Granite black shade, 20 mm thick, (table rubbed and polished) in single piece (in one direction) machine cut, machine polished, bedded and jointed with adhesive suitable for granite/stone & pointed with grout of matching shade including necessary cutting over & including 20 mm thick (average thickness) cement mortar (1:4) screed, as in cooking platform, shelves, RCC counters, window cills & similar situations, complete including all as specified and directed by Engineer-in-Charge. |
| 13 | First quality Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge. |
| 14 | Vitrified ceramic tiles coloured Dark shade (sctratch and stain resistant tiles) 9 mm thick (Square/rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floor,skirting etc set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and including 15 mm thick screed bedding layer in CM (1:6) complete all as specified and directed by Engineer-in-Charge. |
| 15 | Glazed ceramic coloured tiles 450 x 300 x 7 mm thick on vertical surface such as skirting, dado etc. over and including 10 mm thick rendering in CM 1:4 thick set and jointed with 4 mm spacer and grouting the joint of wall with epoxy grout mix of organic coated filler of desired shade, hardener, resin in the ratio of 8:1:2 complete all as specified and directed by Engineer-in-Charge. |
| 16 | First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge. |
| 17 | First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in skirting etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 10 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge. |
| 18 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples as in repair complete all as specified and directed by Engineer-in-Charge. |
| 19 | Preparation of new plastered surfaces of wall and applying two coats of interior acrylic emulsion on walls over and including a coat of alkali resistant primer and 1 mm wall care puty including preparation of surface complete all as specified and directed. |
| 20 | Preparation of new plastered surfaces of ceiling and applying two coats of interior acrylic emulsion on walls over and including a coat of alkali resistant primer and 1 mm wall care puty including preparation of surface complete all as specified and directed. |
| 21 | Preparation of new plastered surfaces of wall and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 22 | (a) Complete removal of existing treatment by scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7\\"/9\\" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed.(b) Material and labour for 1 mm thick wall care putty over the prepared wall surface @ 1kg per sqm by mixing the putty powder by adding water as per manufacturer instructions and mixing it in putty mixer with a capacity of mixing 40 kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty(c) Material and labour for one coat of waterproofing primer/ damp proofing @ 1 ltr per 5 sqm. diluted with 30% by water to be applied using roller(d) Allow 4-6 hrs to dry the surface for painting of subsequent coats.(e) Material and labour for applying two coats of premium acrylic smooth interior emulsion of appoved colour using roller and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to hard-to-reach areas and penetratiion of acrylic emulsion on the surface at complete all as specified and directed. |
| 23 | (a) Complete removal of existing treatment by scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7\\"/9\\" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed.(b) Material and labour for 1 mm thick waterbased cement base wall care putty over the prepared wall surface @ 1kg per sqm by mixing the putty powder by adding water as per manufacturer instructions and mixing it in putty mixer with a capacity of mixing 40 kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty(c) Appliying one coat of waterproofing primer/ damp-proof primer @ 1 Itr per 50 sqft. diluted with 30 % by water to be applied using using an airless spray machine of with a flow rate of 2 ltr per minute having a pressure of 3300 PSI.(d) Allow 4-6 hrs to dry the surface for painting of subsequent coats.(e) Material and labour for applying two coats of waterbased premium exterior acrylic emulsion paint on prepared surface approved colour with silicon additives, with heat reflectant property which can reduce the painted surface temp by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/ litre as per the LEEDs specifications, anti algal properties in two coats @ 1L/ 50 sqft diluted with water as per manufacturer instructions applied over priming coat with using roller complete all as specified and directed. |
| 24 | Note for item no 22 and 23 : The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :-(a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE. (b) The Contractor shall upload with the documents under cover I \\"Memoradum of Understanding\\" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected.(c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures.(d) Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary.(f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes.(g) Washing floors, cleaning glass, joinery , electric fittings , wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge.(h) Sample patch of 10 Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. (j) Guarantee :- The contractor shall furnish a guarantee certificate from approved make in favour of Garrison Engineer for the efficieny of the exterior emulsion paint for 5 years and interior emulsion paint for 3 years during the guarantee period. |
| 25 | Preparation old plastered or unplastered surfaces of wall/ ceiling by washing rubbing down and stopping of painted surfaces of any description filling the all holes / patches with wall care putty to make surface smooth wherever required and applying premium acrylic smooth interior emulsion of appoved colour using roller at any height complete all as specified and directed. |
| 26 | Preparation old plastered surfaces of wall by scrapping down snow soot,moulds, moss and efflorescent salts and treading oil and greasy spots, filling holes, cracks with cement base putty and apply one coat of cement base paint complete all as specified and directed. |
| 27 | Material and labour for providing and applying birla wall care putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 28 | Preparation of old wooden surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 29 | Preparation of old steel or iron surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 30 | Complete removal of existing treatment on wall with wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts, trading oil and greasy spots filling holes, cracks with putty and applying two coat of white wash complete all as specified. |
| 31 | Removal of existing treatment on ceiling surface with wire brushing, scrapping down snow soot,moulds, moss and efflorescent salts and treading oil and greasy spots, filling holes, cracks with cement base putty and apply one coats of plastic emulsion paint over of any description over 10cm girth or width, not otherwise described at any height complete all as specified and directed. |
| 32 | Sheet glass 4mm thick, ordinary quality and glazing with silicon sealant & spring glazing clips using Silicon for fixing of glass in addition to glazing putty, in squares not exceeding 0.5 Sq. mtr in each pane complete all as specified and directed by Engineer-in-Charge. |
| 33 | Sheet glass 4mm thick, ordinary quality and glazing with silicon sealant & spring glazing clips using Silicon for fixing of glass in addition to glazing putty, in squares exceeding 0.5 Sq. mtr in each pane complete all as specified and directed by Engineer-in-Charge. |
| 34 | 75mm bore, PVC (SWR) pipes minimum thickness 3.2mm, 6 kg/ square metre, pressure rating single socketed, in any length with rubber ring joints, laid in trenches, floors & fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts complete all as specified and directed by Engineer-in-Charge. |
| 35 | 110 mm bore, PVC (SWR) pipes minimum thickness 3.2mm, 6 kg/ square metre, pressure rating single socketed, in any length with rubber ring joints, laid in trenches, floors & fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts complete all as specified and directed by Engineer-in-Charge. |
| 36 | PVC(SWR) bends (any radius), for 75 mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge. |
| 37 | PVC(SWR) bends (any radius), for 110mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge. |
| 38 | 25mm dia curtain rod of decorative lining aluminium pipe wall thickness 0.9 mm including bracket and decorative balls/caps at both ends of rod complete all as specified and directed by Engineer-in-Charge. |
| 39 | Note: For the purpose of arriving at Net Contract sum amount, the amount of credit schedule i.e Sch 'A' section II (i.e Rs 1660.00 shall be deducted from the total amount arrived. |
| 40 | Total of Schedule 'A' Rs. Please Enable Macros to View BoQ information |