| 1 | Taking down chowkhats or frames ( without taking down shutters from the frame) not exceeding 1.5 sqm each . |
| 2 | Taking down chowkhats or frames (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each |
| 3 | S&F Factory made single extruded WPC (Wood Polymer Composite solid door & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 4 | S&F, Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer -In- Charge. |
| 5 | M&L for powder coated aluminium three /two track and three shutter (of equal width) sliding type window without sash bars with frame and shutters including frame and necessary jointing clips, rubber packing, neoprene rubber gasket, aluminium snap beading, screws, aluminium fittings, handles, locking arrangement (star lock), bearings two No's for each shutter with 4.00mm thick sheet glass for glazing shutters & stainless steel wire cloth of 0.36mm nominal dia of wire & average width of aperture 1.40mm for wire gauge shutters including following powder coated sections as given in 'JINDAL' catalogue complete all as specified and as directed by Engineer-in-Charge :-(i) Frame (Bottom)-20620. (ii) Frame (Top & Side)-20621.(iii) Shutter vertical (Handle lock)-20846.(iv) Shutter vertical (Int lock)-20845. (v) Shutter (Top)-20844.(vi) Shutter (Bottom)-20847.Note :- (i) The window opening shall be provided with three shutters of equal width.(ii) Two shutters shall be glazed shutters & one shutter shall be with stainless steel wire cloth all as specified hereinbefore.(iii) The shutters shall be placed in such a manner that at a time the entire width of window can be utilized as fully glazed window and at time the same can be utilized as partly glazed and partly gauzed window.(iv) The thickness of powder coating shall not be less than 0.5 micron & the tint shall be as decided by GE.(v) Sealing the gap of frame with Jamb and Cill (alround) using silicon gel at the rate of 0.05 lit/m for both faces of window. |
| 6 | S&F aluminium powder coated ventilator partly fixed and partly louvered type without sash of bars, section as per designation 63400 of IS 737, frame and intermediate made out of aluminium section of size 50.80 x 25.40 x 0.95 mm (Catalogue No 14027 of M/s Jindal) including necessary heavy duty louvers (adjustable with locking arrangements), jointing clips, rubber packing, anodised snap beading, screws alongwith 4.00mm thick pin headed glass for louvers and glazing etc complete all as specified and as directed by Engineer-in-Charge.Note:- (i) The thickness of the powder coating shall not be less than 0.5 micron & the tint shall be as decided by GE.(ii) Unit rate quoted shall be deconed to include for sealing the gap of frame with Jamb and Cill (alround) using silicon gel at the rate of 0.05 lit/m for both faces of window. |
| 7 | S&F aluminium powder coated DECO grill 10mm thick DG 104 not less than 3.97Kg/Sqm fixed with necessary H/F/H channel etc complete all as specified and directed by Engineer-in-Charge. Note : (i) DECO grill fixed with windows with all fittings complete all as directed.(ii) Powder coating of colour as ordered ) |
| 8 | S &F Butt hinges, medium weight, cold rolled, mild steel 100mm long, complete all as specified & directed by Engineer-in-Charge. |
| 9 | S & F Butt hinges, medium weight, cold rolled, mild steel 75mm long, complete all as specified & directed by Engineer-in-Charge. |
| 10 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed, 300mm long, complete all as specified & directed by Engineer-in-Charge. |
| 11 | S&F Aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long, complete all as specified & directed by Engineer-in-Charge. |
| 12 | S&F Aluminium handle, cast type, anodised, 150mm long, complete all as specified & directed by Engineer-in-Charge. |
| 13 | S&F for floor door stopper of 140mm long cover plate of aluminium alloy body and tongue anodised with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge |
| 14 | Taking up or down 15 mm bore steel tubing and connections including cleaning, threading for refixing or removal to store, all as directed by Engineer-in-Charge. |
| 15 | Cutting chases in brick wall, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 20cm girth complete, all as specified and as directed by Engineer-in-Charge. |
| 16 | S&F Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Taking up or down 20 mm bore steel tubing and connections including cleaning, threading for refixing or removal to store, all as directed by Engineer-in-Charge. |
| 18 | S&F Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Dismantling of water tanks any descriptions exc 500 ltr but n.exc1000 ltr cap in any description. |
| 20 | Rotational moulded polyethylene water storage tanks. (cylindrical vertical with closed top ) hoisted and fixed in position, including over flow and drain out pipe complete of 500 litre capacity , all as specified in SSR Part-I. |
| 21 | S&F ball brass valve, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete of 20 mm bore dia . |
| 22 | S&F in repairs 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron pipe complete all as specified and as directed by Engineer-in-Charge |
| 23 | S&F Vitreous china wash down water closet pan (Pedestal pattern) white (excl fixing bolts, flushing cistern and flush pipe) but including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel CP or aluminised hinging device. |
| 24 | S&F vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittings with long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed with & including cutting for & pinning in end of brackets and 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure complete all as specified and as directed by Engineer-in-Charge. |
| 25 | S & F PVC Connection Pipe of 15mm size with PTMT nuts of length 600 mm all as specified and directed by Engineer-in-Charge. |
| 26 | S&F in repairs 50mm bore high density polyethylene pipes (HDPE) of pressure rating 6 Kgf/ Sq. Cm., fixed complete to walls, ceilings or in floors etc. |
| 27 | S&F in repairs PVC flexible waste pipe 32 mm dia complete all as specified. |
| 28 | S&F in repair PVC (SWR) floor trap 75 mm, with steel grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) |
| 29 | S&F Vitreous China Urinal, bowl type (back or corner wall type),With flat back size of 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipecomplete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating,Push cock and Union for discharge pipe. |
| 30 | S&F Brass chromium plated shower rose 125mm size Chromium plated shower roses with or without swivel joints, any size,with arms including fixing to steel pipe or union all as specified and directed by Engineer-in-Charge |
| 31 | S&F in repairs hand shower (Health Faucet), chromium plated with 8mm dia, 1.00m long flexible tube with wall hook all as specified and as directed by Engineer-in-Charge. |
| 32 | S&F PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float and handle including PVC connection 15 mm size with PTMT nuts of length 600 mm long all as directed by Engineer-in-Charge. |
| 33 | S&F CP brass two way bib tap with wall flange complete all as specified. Make : Prayag, Cat No 7512 |
| 34 | S&F 15 mm dia angle cock with wall flange of brass with chromium plated complete all as specified and directed by Engineer-in-Charge. |
| 35 | S&F Looking mirror 600 x 450 beveled edge mirror of selected quality glass 5mm thick mounted on 6 mm thick AC building board or commercial ply and fixed to wooden plugs with CP brass screws and cup washers etc, complete all as specified. |
| 36 | S&F towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified & directed by Engineer-in-Charge. |
| 37 | S&F in repair CP soap dish complete all as specified and directed by Engr-in-Charge. |
| 38 | S&F in repair Chromium Plated toilet paper holder fixed with (CP) brass screws of approved quality |
| 39 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. |
| 40 | M & L Rendering 10 mm thick in cement mortar 1: 3 on concrete surfaces as in ceilings finished even and smooth without using extra cement, complete all as specified. |
| 41 | M & L Rendering 15mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement with integral liquid water proofing compound as per manufacturers instructions complete all as specified and directed.(Note : Supply only integral liquid water proofing compound shall be measured and paid for separetely). |
| 42 | M & L Rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces finished even and smooth with out using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 43 | Preparation of new plastered surfaces of ceiling and applying three coat of white wash , complete all as specified and directed by Engineer-in-Charge. |
| 44 | Preparation of new plaster surfaces of wall applying two coats of oil bound emulsion over one coat of chalk whitening over one coat of wall putty on plastered surfaces of walls . |
| 45 | Complete removal of existing treatment on old surface of wall and applying 2 coats of oil bound distamper emulsion over a coat of primer over 1 mm thick wall care putty |
| 46 | M&L for preparing new plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm. |
| 47 | Preparation of old or previously untreated steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint, complete all as specified & directed by Engineer-in-Charge. |
| 48 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-Charge. |
| 49 | M&L ceramic light shade tiles 7-8mm, area of each tile exceeding 0.18 sqm, but not exc 0.36 Sqm in floors etc set & jointed in neat cement slurry & pointed in white or coloured cement to match including and over 15 mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 50 | M&L Non skid ceramic jointless coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge . |
| 51 | M&L Glazed ceramic coloured tiles of size 600mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed by Engineer-in-Charge. |
| 52 | Demolition of cement concrete ( un reinforced ) in ground floors and paving n exc. 15 cm. Thickness, below or above ground level . |
| 53 | 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection and PCC path finished even and smooth with out using extra cement including forming and filling of joints with bituminous filler all as specified and directed by Engineer-in-Charge. |
| 54 | S&F in 75 mm dia PVC SWR pipe, single socketed in any length fixed in floor/wall and connected nahani trap all as specified and directed by Engineer-in-Charge |
| 55 | S&F, 75 mm bore PVC (SWR) bends any radius, with or without excess door. |
| 56 | S&F , 75 mm bore PVC (SWR) branch piece, double (double Y) equal or unequal.with excess door |
| 57 | S&F , 75 mm bore PVC (SWR) junction single, (Single T) ,with excess door, equal or unequal |
| 58 | S&F in repair 75mm bore PVC (SWR) vent cowl all as specified and directed. |
| 59 | S&F in repairs 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as directed. |
| 60 | S&F , 110 mm bore PVC (SWR) bends any radius, with or without excess door. |
| 61 | S&F , 110 mm bore PVC (SWR) branch piece, with excess door, double (double Y) equal or unequal, with or without excess door. |
| 62 | S&F , 110 mm bore PVC (SWR) junction double, (double T), equal or unequal, with excess door |
| 63 | S&F 110mm bore PVC (SWR) vent cowl all as specified and directed by Engineer-in-Charge. |
| 64 | Material and labour for complete removal of existing WPT course or any other kind of treatment over roof slab, parapets, chimney stacks, etc including cement plaster/PCC over RCC roof and cleaning the surface with wire brushes and water, removing of insolvent materials and depositing of the same outside MoD land and brushing neat cement slurry @ 3 Kg of cement per Sqm over the cleaned surface and provide 15mm thick screed bed/bedding layer/plaster in CM 1:3 mixed with integral Water Proofing Compound (WPC) as per manufacturer's instructions and finishing the surface even & smooth without using extra cement while the cement slurry is still green on RCC roof/parapet, provide oil bound bituminous primer @ 0.30 Kg/Sqm after bedding layer/plaster is completely dried, provide minimum 4mm thick APP based modified polymeric water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyster matt fabric weighing not less than 160 gms/Sqm with over laps 75 mm longitudinal direction (side laps) and 100 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed and finally finishing the top surface with one finishing coat of bituminous aluminium paint complete all as specified and as directed by Engineer-in-Charge.Notes: (i) WPC shall be measured & paid for separately (ii) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT (iii) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (iv) The net area of water proofing treatment shall be measured without any extra allowance for laps. |
| 65 | 25 mm thick (average thickness) PCC1:2:4, type B-0 using 12.5mm graded stone aggregates as in floor by maintaing required gradient/undulation, finished even and fair as in floor and roof in, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply only Integral Water Proofing Compound (ISI Marked) of Make: CICO, Acco Proof, Impermo, Aqua flex, Dr Fixit, Pidilite as approved by GE. |
| 67 | Dismantling stone slabs and tiles of any description or thickness in kitchen platform and similar work laid, bedded and pointed in cement mortar complete all as specified and directed by Engineer-in-Charge. |
| 68 | M&L 20 mm thick granite black marble (of any type) work (table rubbed & polished) in steps, jambs, pillars, window-cills cooking platforms & like including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite laid over and including Screed bed or bedding layer of mortar 15mm thick for laying floor in CM 1:4 finished even & rough to receive top layer, complete all as specified and directed. |
| 69 | M&L Providing granite edge moulding to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. Complete |
| 70 | M&L Machine cut kota stone slab flooring 15-20 mm thick over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing all as directed. Note : The rate are including of full moulding edging of kota stone . The kota stone will be used in tread in single piece with two grooves. |
| 71 | M&L Machine cut Kota stone 15-20 mm thick in riser steps, skirting, dado and pillar laid over cement plaster and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing mirror finish and polishing including15 mm thick screed in CM 1:4. complete. |
| 72 | M&L Mirror polishing on marble/ granite/Kota stone/ stone work where ever required to give high gloss finish complete all as specified and as directed by Engineer-in-Charge. |
| 73 | Dismantling of Mangalore pattern roofing tiles with ceiling tiles or slate roofing |
| 74 | Dismantling of battens for tiles, shingles etc of any size including tilting fillets spacers exc 15 cms |
| 75 | Dismantling of Plain or corrugated steel/GI sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 76 | Dismantling boarding, any description, fixed any position with nails |
| 77 | M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc confirming to Fe-410W (Gde E-250) quality -A grade complete all as specified and directed by Engineer-in-Charge |
| 78 | S&F Mild steel screw bolts 5 to 10mm dia of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, self drilling/ tapping stainless steel screws M6, with 3 mm EPDM seal washer , exc 10 and n.exc 15cm long |
| 79 | S &F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 80 | S&F MSA Flat wind ties for roof including securing bolts, posts and struts including all necessary drilling bolt or riveting etc and similar work confirming to FE-290 Gde E-165. |
| 81 | Dismantling of Aluminum Partition including Grid and frames and fixing of aluminium Partition with Powder coated Frame having MDF board in the lower portion and fixing of frosted glass on upper portion with 4mm glass including all fittings complete all as specified and as directed by Engineer-in-Charge. |
| 82 | M&L preparation of new steel surfaces of any descriplain, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide chrome primer all as specified and as directed by Engineer-in-Charge. |
| 83 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall/Shed, fixed with self tapping screws all as specified and as directed by Engineer-in-Charge. |
| 84 | Dismantling wall and ceiling boards(fibre,pulp, unsulation etc) or unsulation board/slab/beam kob, any thickness including cover gillet complete all as specified and directed by Engineer-in-Charge |
| 85 | S&F Arm Gyp-FB ceiling snow Frost vinyl face, washable metallized polyester foil backing ,vinyl covered edges, suspended ceiling on suspension system. Panels shall be of Size 600 mm x 600 mm x 9 mm, having 7 kg/SQM, including providing Grid system for fixing ceiling tiles shall comprise of suspension system with true horizontal level, suspended on inter locking tegular “Select” system with 15mm black flanges incorporating a 4mm central reveal in black colour and a load carrying capacity of minimum 14.50 kg/m2 with birdsmouth notches metal grid of hot dipped galvanized steel sections consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 15x32 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 15mmx25mm made of 0.30 mm thick (minimum) sheet, 1200mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200mmx600 mm and secondary cross \\"T\\" of length 600 mm and size 15mmx25mm made of 0.30 m thick (minimum) sheet to be interlocked at middle of the 1200mmx600 mm panel to form grids of 600mmx600mm and wall angle of size 20mmx15mmx0.3 mm and laying false ceiling tiles of approved texture in the grid including, required fitting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85mm x 30mm x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 15 mm of all T-sections all complete for all heights as per specifications, drawings incl dismantling of old ceiling, all as specified and directed by Engineer-in-Charge. |
| 86 | Dismantling structural steel works including steel work in doors, gates, framed truss etc complete all as specified and as directed by Engineer-in-Charge. |
| 87 | S&F Framed work as in doors Window Grill, Grating, ladder ,Hand rail, or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete.Fe 410 W(Gde)-E-250 Quality-A Complete all as Specified and directed by Engineer-in-charge |
| 88 | S&F in repairs steel rolling shutters thickness of laths in 1mm, without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete gear operated type with bevel gear box and crank handle |
| 89 | S&F safety lever locks mild steel with 4 levers for rolling shutters |
| 90 | S&F in repair aluminium powder coated (fancy type) tubular curtain rod, 20mm dia, complete all as specified and as directed by Engineer-in-Charge. |
| 91 | S&F in repair bracket aluminium powder coated (fancy type) for 20 mm dia tubular curtain rod(for item above) complete all as specified and as directed by Engineer-in-Charge |
| 92 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 93 | M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.(a) One light point controlled by one 5 Amps switch one way |
| 94 | All as per item No 93 here-in-before but One ceiling fan point controlled by one 5 Amps switch one way |
| 95 | All as per item No 93 here-in-before but One ex fan point controlled by one 5 Amps switch one way |
| 96 | All as per item No 93 here-in-before but One 3 pin 5 Amp switch socket outlet on independent board |
| 97 | All as per item No 93 here-in-before but One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 98 | M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor. |
| 99 | M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for the following points:-(a) One light point controlled by one switch. |
| 100 | All as per item No 99 here-in-before but One fan point /Exhaust fan/ wall fan point controlled by one switch. |
| 101 | All as per item No 99 here-in-before but One 6A socket point controlled by one switch on independent board |
| 102 | All as per item No 99 here-in-before but One 6A socket point controlled by one switch on same board Please Enable Macros to View BoQ information |
| 103 | All as per item No 99 here-in-before but One 6A socket point controlled by one switch on same board Please Enable Macros to View BoQ information |