Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR Name of Work :- DNIT FOR THE RENOVATION OF EXISTING CIRCUIT HOUSE BUILDING AT JALANDHAR (FY 2026-27) Contract No: Civil Works Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | CIVIL WORK |
| 3 | Scraping(a) White wash and colour wash |
| 4 | Scraping(c) Cement plaster |
| 5 | Preparation of plastered or concrete surfacef or painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 6 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 7 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 8 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999):(a) Commercial with elm or gurjan facing on both \ Sides withlaminated core and lipped edges:-(iv) 35mm thick |
| 9 | Providing and fixing ply wood, plain lining, butt jointed including PVC Plug placed at 45 cm to 65 cm centers complete with necessary nails (Frame work shall be payable extra)(b) 6mm thick decorative ply wood teak faced on one side. |
| 10 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.Spirit polishing two coats including a coat of wood filler on wood work |
| 11 | Kiln seasoned Hollock wood doors shutter with 12mm thick phenol Bonded BWP ply ISI Marked anchor, Kit ply, Nova Teak, National Or equivalent including Hinges, Screws, Shocks Cleats, Stops and Cordsetc. complete fixed in position (Single Leaf).a Phenol Bonded B.W.P. ply paneliii) 30 mm thick |
| 12 | Providing and fixing PVC Panelling on Wall 9\\" wide complete A5Satisfaction Engineer in Chage |
| 13 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cementand 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded). |
| 14 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 15 | Removing doors and windows together with the dismantling of walls(i) Doors |
| 16 | Removing doors and windows together with the dismantling of walls(ii) Windows |
| 17 | Removing doors and windows together with the dismantling of walls(iii) Clerestory windows |
| 18 | Providing and applying Anti Termite Treatment using post constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 3 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications by drilling holes in the floor slab & along skirting 300 mm apart & 12 mm dia, drilling holes along all possible entry points such as junctions of floor and walls, door frames, sewage lines, entry points , etc. & injecting them with the chemical solution. |
| 19 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make proved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : (a) For fixed portion and chawkhats |
| 20 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make proved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : (b) For shutters of doors, windows & ventilators including providing andfixing hinges/pivots and labour for fixing of fittings wherever requiredincluding the cost of PVC Plug / neoprene gasket required |
| 21 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc.complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 22 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)i) Float glass panes of 5 mm thickness |
| 23 | 20mm thick cement plaster 1:5 in two coat work |
| 24 | 12.5 mm thick cement plaster 1:5 |
| 25 | Providing and fixing mineral fibre false ceiling tiles at height upto 4 mtr. of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@ 80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. with 16mm thick beveled tegular mineral fibre ceiling tile (NRC 0.55 to 0.6) size 595x595mm thick |
| 26 | Providing and fixing ply wood, plain lining, butt jointed including PVC Plug placed at 45 cm to 65 cm centers complete with necessary nails (Frame work shall be payable extra)(d) 12mm thick decorative wood with teak faced on one side |
| 27 | Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 28 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 29 | Providing & fixing 6\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 30 | Providing & fixing 6\\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 31 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 32 | Providing and fixing factory made uPVC white colour asement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of rofile shall be acceptable. Variation in profile dimension on higher side shall be accepted but no extra payment on this account shall be made (b) Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm) |
| 33 | Disposal of Malba |
| 34 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 35 | Supply & Fixing Fiber Glass Coated Mesh with thickness of 45 Gsm for the water proofing of roof terraces, bathrooms , Water tanks, etc. Thesurface to be levelled, finished, made smooth before fixing of Fiber Glass Mesh, complete in all respect as per manufactures specification and as per directions of Engineer-in-Charge. |
| 36 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where speciallyspecified. |
| 37 | PUBLIC HEALTH WORK |
| 38 | Sub Head No.1 Sanitary Installation |
| 39 | Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 40 | Chinaware Floor Mounted One Piece EWC rim less type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) size 69x36x74 cm with P trap or S trap and seat cover complete in all respect. |
| 41 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. |
| 42 | With C.P. Brass nut |
| 43 | Providing and fixing Stainless steel health faucet complete in all respect. |
| 44 | Providing and fixing in position C.P. brass overhead shower round or square 1 flow without shower arm with 15mm i/d inlet of approved make (to the approval of Engineerin-charge) complete in all respect. |
| 45 | CP Brass rain Fall Shower without arm 8\\" square |
| 46 | Providing and fixing in position C.P. brass overhead shower arm chrome round or square with 15mm i/d inlet of approvedmake (to the approval of Engineer-in-charge) complete in all respect. |
| 47 | CP Brass rain Fall Shower arm 15\\" length square chrome |
| 48 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete inall respect. |
| 49 | C.P. Brass khunti with 6 pegs |
| 50 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect |
| 51 | Size 630 mm x 450 mm x 830 mm |
| 52 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. Vitreous chinaware standard white pedestal for wash hand basin. |
| 53 | Providing and fixing in position C.P brass Single Lever basin mixer without Popup waste with 450 mm Long Braided Hosesapproved make (to the approval of Engineerin- charge) complete in all respect. |
| 54 | Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineerin- charge ) fixed in with rawl plugs and C.P brass screws complete in all respect. |
| 55 | C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm |
| 56 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. |
| 57 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 58 | C.P. Brass Accessories: |
| 59 | C.P. Glass Shelf 600mm long |
| 60 | C.P. brass towel rack 600mm long with lower hangers |
| 61 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 62 | C.P. brass towel Rails size 15mm dia 610mm long |
| 63 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in allrespect |
| 64 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) |
| 65 | Size 1500mmx600mm or any other size |
| 66 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval ofEngineer-in-charge ) complete in all respect. Note:-To be provided only for VIP Installations and with prior approval ofthe Engineer-in-charge. |
| 67 | C.P. brass Bib cock with Wall flange |
| 68 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect |
| 69 | PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 70 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 71 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval ofEngineer-in-charge ) complete in all respect. Note:-To be provided only for VIP Installations and with prior approval ofthe Engineer-in-charge. |
| 72 | C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body) |
| 73 | C.P.brass 15mm Angular stop cock with Wall flange |
| 74 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 75 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. |
| 76 | i) C.P. Brass extension piece, 25mm long to 50mm long |
| 77 | Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge. |
| 78 | Eurpoean/Indian/Orissa W.C., |
| 79 | PVC / China Ware Cistern |
| 80 | Wash Hand Basin / Urinal Pot |
| 81 | CP Bib Cock/Angle Cock/StopCock/Shower/Bottle Trap |
| 82 | Wall mixer / Sink Mixer / Basin Mixer /Concealed Stop Cock |
| 83 | Sub Head No.2 Internal Water Supply |
| 84 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 85 | b) c CPVC SDR 11 Pipe & fitting 20mmo/d |
| 86 | c) c CPVC SDR 11 Pipe & fitting 25mmo/d |
| 87 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 88 | Size 150 mm x 150 mm |
| 89 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 90 | Through wall 11.43 cm thick |
| 91 | Through wall 22.86 cm thick |
| 92 | Cement concrete plain1:2:4 mix |
| 93 | with stone ballast mixing by manual means |
| 94 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 95 | Providing and fixing in position automatic brass Ball Cock intanks. iii)25mm i/d |
| 96 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 97 | G.I. tank nipple 25mm i/d |
| 98 | Providing, fixing and jointing Brass Ball valvesscrewed with SS/BRASS ball & spindle &Teflon seats, on G.I. Pipe lines including allcarriages complete. |
| 99 | 25mm i/d Brass Ball valves |
| 100 | Sub Head No.3 Internal Sewerage |
| 101 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonagepipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 102 | Single Socket Type B |
| 103 | b) 110mm o/d SWR UPVC pipe lines laid complete |
| 104 | Providing and fixing in position SS Gratingwith frame of approved make (to the approval of engineer in charge) complete in all respects |
| 105 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 106 | For 110mm o/d pipes |
| 107 | ii) Single Tee With Door |
| 108 | iii) Single Tee |
| 109 | iv) Door Elbow 90 Degree |
| 110 | vi) Vent Cowls |
| 111 | vii) Reducer 110mm x 75mm |
| 112 | ix) P Trap/Floor Trap 110mm x 110mm |
| 113 | xi) Single Y-Junction |
| 114 | Sub Head No.4 Flooring & Wall tiles |
| 115 | 12.5 mm thick cement plaster 1:2 |
| 116 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b)Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed withwater curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. including walls upto 2'-0\\" high beams |
| 117 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by themanufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 118 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 119 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by themanufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 120 | By Manual Means (A) Stone (building or pitching) Sand, Earth, Fly Ash, Bajri, Shingle, Spalls, Brick bats, Brick ballast and Stone metal. |
| 121 | (i) Earth,Surkhi, Sand, Earth, Fly Ash, Bajri, Ballast, Stone boulders, Kankar and building rubbish, Earth. |
| 122 | 0-6.0 km |
| 123 | Cement concrete 1:2:4 |
| 124 | a With stone ballast or shingleI mixing by manual means |
| 125 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made withm40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes,M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 126 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 127 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 128 | Sub Head No.5 RO & Air Conditioner System |
| 129 | Providing & Installing 5 Star (inverter) split type wall mounted air conditioner capacity 2.0 tonne with arrangement for installing OD units including connection of inlet and outlet copper tubes (Rate is inclusive of copper pipe 3.00mtrs and cable upto 3.00mtrs length ) with proper insulation, cable link between ID unit and OD units stand for OD unit and installing charges complete in all respects |
| 130 | Providing & Installing 5 Star ( inverter) split type wall mounted air conditioner capacity 1.5 tonne with arrangement for installing OD units including connection of inlet and outlet copper tubes (Rate is inclusive of copper pipe 3.00mtrs and cable upto 3.00mtrs length ) with proper insulation, cable link between ID unit and OD units stand for OD unit and installing charges complete in all respects |
| 131 | AUTOMATIC VOLTAGE STABLIZER: |
| 132 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- |
| 133 | Automatic Voltage Stablizer 5 KVA |
| 134 | For Air Conditioner |
| 135 | Providing laying hard soft copper concealing of copper pipe of various dia as per requirment and wall thickness 0.8 mm insulated, 4mm electric wire sheathed 3 care double insulated / taping laying in chase cutting of wall and reparing the same within the building and installing charges complete in all respect. |
| 136 | Extra for coopper wire |
| 137 | Providing, laying, jointing, fixing and testing uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. |
| 138 | 25mm i/d |
| 139 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 140 | Water Cooler Full Steel Body 150/150 ltr without Stablizer |
| 141 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- |
| 142 | Automatic Voltage Stablizer 5 KVA For water cooler |
| 143 | Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make(to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 144 | Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. |
| 145 | 25 litre capacity water heater |
| 146 | Supply of GLEN Oil Filter / Heater (11 FINN) complete in all respect. |
| 147 | Blue Star 500 L Double Door Standard Deep Freezer (White, CHFD500NEYW,DD,White, 500 Ltr Standard Deep Freezer, 3 Star) |
| 148 | Sub Head No.6 Credit of old material |
| 149 | Credit od old Air conditioners |
| 150 | Credit of old Electric type Stablizers |
| 151 | Credit of Old Copper Pipe |
| 152 | Credit of old CP Fixtures |
| 153 | ELECTRICAL WORK |
| 154 | Electrical Installation |
| 155 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: |
| 156 | Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) |
| 157 | Wiring fan point (Without fan box) |
| 158 | Wiring light point |
| 159 | Wiring call-bell point |
| 160 | Wiring 6Amp. wall socket point |
| 161 | Wiring 6Amp. Plug control comprising wall socket point |
| 162 | Wiring 16/20Amp. power plug control point |
| 163 | Wiring light point with double control switches. |
| 164 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 165 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 166 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 167 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 168 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 169 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 170 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 171 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 172 | Wiring TV socket point (one module) |
| 173 | Wiring Telephone socket point RJ11 (one module) |
| 174 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 175 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 176 | Overall size 1.5sq.mm (Un-sheathed) |
| 177 | Overall size 2.5sq.mm (Un-sheathed) |
| 178 | Overall size 4 sq.mm (Un-sheathed) |
| 179 | Overall size 10 sq.mm (Un-sheathed) |
| 180 | Overall size 16 sq.mm (Un-sheathed) |
| 181 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 182 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 183 | Overall size 120sq.mm (3½ Core) Un-armoured (Loose) |
| 184 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks,M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 185 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 186 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 187 | Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) |
| 188 | COPPER EARTHING :-(Upto 14 metre in Length):-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 189 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 190 | COPPER EARTHING STRIP (As Additional Length):Fixing additiona Length of earthing with Copper Tape (On Surface/Flushed) with pett materia as required etc.:- |
| 191 | Additional Length 20mm x 3mm thick Copper Tape . |
| 192 | MINIATURE CIRCUIT BREAKERS: |
| 193 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 194 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 195 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 196 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: |
| 197 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 198 | TP&N Horizontal Double Door Distribution Board 6 way each |
| 199 | TP&N Horizontal Double Door Distribution Board 8 way each |
| 200 | LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): LT PANELS: |
| 201 | Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel.The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . |
| 202 | Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc.Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site. Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:- |
| 203 | LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm) |
| 204 | MCCB's (FOR PANELS & SHEET ENCLOSURE): |
| 205 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 206 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 207 | MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 208 | MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 209 | ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure): |
| 210 | Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- |
| 211 | On Load Change Over Switch Four Pole 200amp., 415volts (With Sheet Enclosure) |
| 212 | MS SHEET ENCLOSURE FOR MCCB's: |
| 213 | Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 214 | MS Sheet Enclosure having provision for MCCB 200-630Amp.with extended rotary handle (Approx. Size 750mm x 300mm x 250mm) |
| 215 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: |
| 216 | CUBICAL PEDESTAL: |
| 217 | Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 218 | Cubical Size 1400mm high, 1200mm wide and 500mm deep with platform dimensions 1300mm x 600mm x 450mm |
| 219 | Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 220 | Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 221 | Supply and erection of Recessed Mounted 2FT X 2 FT 36 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 222 | Supply and erection of AC Ceiling Fan 1200mm (48\\")-3star suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body 3Nos of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfaction of the Engineer in-charge at site. |
| 223 | Supply and erection of 18 Watt LED Downlight Elegantly designed sleek recessed mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver.with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 224 | Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in- charges at site. |
| 225 | Supply ,erection,testing & commissioning of 12volt- 200 AH Tall Tubular Battery with warranty 36 months including connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. |
| 226 | Supply ,erection,testing & commissioning of Pure Sine Wave Invertor 2000VA with 24month warranty with Ttolley for Two tall tubular batteries,connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. |
| 227 | Digital Hybrid IP-PBX System |
| 228 | Supply & erection of Digital Hybrid IP-PBX System Digital 100% Non Blocking, 06 No. Universal Slots, Universal SMPS,Auto Attendant, CLI, GSM Trunk, Digital Extension & IP Connectivity, Voice Mail, PRI Connectivity including all features listed in Product Boucher. Configured for 04 Trunk,04 Digital Extn Ports, 00 GSM Trunk Ports, 00 PRI of 32 Channels & 24 Normal Extensions Expendable to 48 TDM Ports & 50 IP Extension. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 229 | Supply & Erection of 50 Pair MDF/50 Pair IDF with Original Krone Module lock & key facility. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 230 | Supply & Erection of 10 Pair DB with Original Krone Module lock & key facility. complete in all respects as approved and desired by the Engineer-in-charge at site.e. |
| 231 | Supply & Erection of 20 Pair DB with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 232 | Supply & erection of Basic Wired Telephone with Display, Redial, CLIP & Mute Compatible with EPABX System. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 233 | Supply & erection of Featured Wired Telephone with Blue Backlit Display, Redial, CLIP, 2 Way Speaker, Calculator, Mute Compatible with EPABX System. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 234 | Supply & erection of Operator-cum-maintenance console/Digital Phone with Small Backlit Display, 16 Direct Dialling Keys, HD sound quality, Duplex Speaker Phone, Touch sense keys, 16 Direct Dialling Keys, HD sound quality, Duplex Speaker Phone, Touch sense keys, Polyphonic Ringtone, Full Duplex Speaker Phone, Hold, Conference, Redial, Transfer, Message Wait Lamp, Ringer Lamp, 49 keys including 4 Context Sensitive Hard Keys, 1 x RJ9 Handset Port, 240X64 Pixels Graphical LCD with Backlit, LED for Incoming/Ongoing Calls, Mute, Hold, Intuitive User Interface with Icons, Multiple Languages Caller ID with Name, Number, Room Monitoring, Operating Temperature Range 0 to 45°C including all features listed in Product Boucher, complete in all respects as per satisfaction of the Engineer in-charge at site |
| 235 | Supply & erection of 1KVA Online LIT sine wave UPS/ Power Plant with in built SMF batteries having 30 Minutes backup time complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 236 | Supply and erection of telephone cable with solid bare copper conductor, special grade PE insulation, paired, polyster taped, nylon rip cord, FR PVC sheathed, conforming to TEC Specification No. G/WIR-06/03 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 237 | Telephone Cable 0.5 Sq.mm, 2 Pair |
| 238 | Telephone Cable 0.5 Sq.mm, 10 Pair |
| 239 | Video Conference System |
| 240 | Supply Installation Testing and Commissioning of Advanced conference System comprising of 220V AC & 24V DC operation, 50 watt PA Amplifier, 3 Mic & 1 Aux input, MP3 Recorder & player USB & Card Reader, Intelligent sound reinforcement, Speaker output Automatic Mic off in delegate unit. complete in all respects as desired and approved by the engineer in charge at site. |
| 241 | Supply Installation Testing and Commissioning of Chairman Unit having highly sensitive 18.5’’ long gooseneck microphone with Talk switch with LED & Priority switch with LED, built-in speaker, Bright ring LED indicator, volume control & headphone output. complete in all respects as desired and approved by the engineer in charge at site. |
| 242 | Supply Installation Testing and Commissioning of delegate unit having highly sensitive 18.5’’ long gooseneck microphone comfortable sharing by two delegates with Talk switch with LED, built-in speaker, Bright ring LED indicator, volume control & headphone output & automatic mic off. complete in all respects as desired and approved by the engineer in charge at site. |
| 243 | Supply Installation Testing and Commissioning of 10 Meter Long Audio cable for connecting controller unit with mic complete in all respects as desired and approved by the engineer in charge at site. |
| 244 | Supply Installation Testing and Commissioning of 10 Watt Colum Speaker 100V Line Support complete in all respects as desired and approved by the engineer in charge at site. |
| 245 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: |
| 246 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 247 | Overall size 1.0sq.mm (32/0.20mm), 2Core |
| 248 | Supply, erection, Installation Testing and Commissioning of 25mm x 45 mm pvc cable management tray including erection complete in all respects as desired and approved by the engineer in charge at site. |
| 249 | Supply Installation Testing and Commissioning of 15U Wall mount 19’’ Rack with glass door, lock & key facility 450mm-550mm depth with CPD complete in all respects as desired and approved by the engineer in charge at site. |
| 250 | Supply Installation Testing and Commissioning VHF/UHF wireless Mic having Long range with receiver and volume control, RF Output Power10mW (Max.) Carrier Frequency Range 630-664MHz with POWER ON/OFF switch and Channel Frequency Display. complete in all respects as desired and approved by the engineer in charge at site. |
| 251 | Campus Lighting |
| 252 | XLPE INSULATED UNARMOURED CABLES (LOOSE): |
| 253 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed unarmoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 254 | Overall size 10sq.mm (2Core) Armoured (Loose) |
| 255 | XLPE INSULATED ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 256 | Overall size 10sq.mm (2Core) Unarmoured (On-Surface) |
| 257 | Overall size 16sq.mm (4Core) Armoured (On-Surface) |
| 258 | G.I. EARTHING: |
| 259 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 260 | Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length) |
| 261 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 262 | GI Earth rod 20 mm dia., 3 mtr. Long |
| 263 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 264 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 265 | Overall size 1.5sq.mm (Un-sheathed) |
| 266 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 267 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 268 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: CUBICAL PEDESTAL: |
| 269 | Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 270 | Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm |
| 271 | MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 272 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 273 | MS SHEET ENCLOSURE FOR MCCB's: |
| 274 | Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 275 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 276 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: |
| 277 | MINIATURE CIRCUIT BREAKERS: |
| 278 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 279 | MCB Double Pole 6-32amp. (10kA, Curve-C) |
| 280 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 281 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: |
| 282 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 283 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 284 | Supply and erection of G.I. Pipe (A-Class) Single arm bracket of suitable length to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the existing surface/ wall with 2nos. MS flat clamp 25mm x 5mm, 30cm long and 4nos. fastner 10mm x 75mm long with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:- |
| 285 | Single Arm Bracket 1 metre Long G.I. Pipe 40mm Dia. |
| 286 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 287 | Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 288 | PAINTING INCLUDING LABOUR AND MATERIAL: |
| 289 | Painting of Galvanized iron pipe pole including bracket with two coats of aluminium paint (With brush):- |
| 290 | Overall Length 4 Metre |
| 291 | Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, inner dimensions 250mm x 200mm x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's). The SMC Junction Box is to be fixed with the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement & two coats of white snowcem complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 292 | Cement Concrete Muff of Overall Size 450mm dia., 80cm Long |
| 293 | Supply and erection of LED Flood Light 120 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty includingtheir drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 294 | Supply and erection of LED Flood Light 80w (including LED driver) in aluminium pressure die cast housing with toughned glass cover (IP66 Protection) and secondary lenses with IP66 protection having efficiency of LED fixture minimum 120 lumens per watt and operating voltage between 140 to 270volt, input frequency 50Hz + 3% complete along with erection of the same with connections, testing etc. Flood light should install on existing parapet complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and Specification of the LED fitting should be as approved by O/o Advisor(Technical), Govt. of Punjab vide Letter no. AT/2021/GL/1410-1422 Dated 06/05/2021.Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab. |
| 295 | Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear ( IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 296 | Supply and erection of 40/45 watt LED Decorative Post Top for 360 Degree indirect light with IP65 protection with high power LEDs as light source LEDs as light source installed on existing G.I. pole. including connection testing. Complete in all respect as approved and desired by the engineer incharge of the work at site. |
| 297 | Service of 110KVA DG set |
| 298 | Service and repair of 110KVA DG set (Make : Crompton) including radiator repair, AVR repair, Self Start repair, replacement of Lubricating engine oil, Oil Filters, Fuel Filters, Air Filter set, Coolant, Complete in all respect as desired by Engineer incharge at site. |
| 299 | Supply and Installation of Battery charger 12V, 6A Complete in all respect as desired by Engineer incharge at site. |
| 300 | Supply, erection, testing & commissioning of 150 AH Battery with 3 year Guaranty and 2 year warranty. complete in all respects as per satisfaction of the Engineer in-charge at site. |
| 301 | Credit of Old dismantled material Total in Figures 10519559.0 10519559.0 INR One Crore Five Lakh Nineteen Thousand Five Hundred & Fifty Nine Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy