| 1 | B/R WORKS :Dismantling of (corrugated or semi corrugated ) sheets as in roof covering of any patterncomplete all as specified and directed. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding/ridges etc , fixed with self tapping screws complete all as specified and directed. |
| 4 | S&F 0.56mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length andgirth as fixed) complete all as specified and directed. |
| 5 | Taking down cement plaster including raking out joints hacking for key, scrubbing down with water complete all as specified and directed. |
| 6 | M&L for rendering 15 mm thick on fair face of external walls of brick surface in two layers (10 mm and 5 mm thick)in cement mortar in 1:4 incl mixing of water proofing compound in 2nd layer only layer (Water proofing compound shall be measured and paid for separately). complete all as specified and directed. |
| 7 | M&L for rendering 10 mm thick on brick wall the fair face of Brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | Supply only WPC of approved make complete all as specified and directed. |
| 9 | M&L for preparation of new plastered or unplastered surface of wall and applying three coats of white wash etc complete all as specified and directed. |
| 10 | M&L for preparation of new plastered surface of wall ,chajja facia etc with putty 1mm thick and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. all as specified and directed. |
| 11 | Demolition of brick work in cement mortar complete all as specified and directed. |
| 12 | M&L for brickwork with subclass 'B' bricks well burnt old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 13 | Demolition of cement concrete (un reinforced) in ground floor and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 14 | M&L for providing 100mm thick PCC 1:2:4 type B-2 (40mm graded aggregate) as in floor, finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 15 | M&L cement concrete 75mm thick 1:2:4 type B-2 using 40mm graded stone aggregate as in pathways/hardstanding laid in alternate ways, each panel not exceeding 3.00 Sqm finished the surface even and fair without using extra cement and joint to be filled with Bituminous mastic filling in proportion of Bitumen and sand (1:2) including necessary form work complete all as specified and directed. |
| 16 | M&L for broken stone boulder as hardcore of gauge n exc 63mm,deposited,spread and levelled in layers n exc 15 cm thiock,watered and rammed to a true surface complete all as specified and directed. |
| 17 | M&L For 50mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base of floor etc complete all as specified and directed. |
| 18 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand all as specified and directed. |
| 19 | M/L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) Ditto, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed ®as in foundation , mass concrete. complete all as specified and directed. |
| 20 | M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 21 | S&F Framed work such as grills,gratings, etc.. with ends of barsshouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar workconforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 22 | Taking down Shutters with chaukhat of any description n exc 1 sq. m each complete all as specified and directed. |
| 23 | M&L for 2nd class hard wood plain , solid straight chowkats and frames , wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 24 | S&F of 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 25 | Supply only 4mm thick Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane complete all as specified and directed. |
| 26 | M&L preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer including anty termite treatment complete all as specified and directed. |
| 27 | S&F 75mm size butt hinges, Extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed,type C-22 fixed in repair and brass/bronze pin is provided in lieu of mild steel hinge pin complete all as specified and directed. |
| 28 | M&L preparation of new steel surface surface any description not otherwise described and over 10cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 29 | M&L preparation of old steel surface surface any description not otherwise described and over 10cm width or girth applying two coats of synthetic enamel paint all as specified and directed |
| 30 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 31 | S&F 1.25mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete:gear operated type with bevel gear box and crank handle all as specified and directed. |
| 32 | S&F Safety lever locks mild steel with 4 levers for rolling shutters all as specified and directed. |
| 33 | S&F Ball bearing for rolling shutters complete all as specified and directed. |
| 34 | M&L for Oiling/greasing existing rolling shutters for easing adjusting for smooth functioning of steel rolling shutter including guide channels of area up to 21 Sqm complete all as specified and directed. |
| 35 | M&L for Servicing of steel rolling shutters of area upto 21 sqm (single opening) of lever operated with rectification of minor defects, overhauling, greasing, lubricanting of guide rails and refixing clamps, rivetting including necessary repairs to the locking arrangements and replacement of wornout spare parts such as gear/worm/interlocking laths/ball bearing in order to bring the rolling shutters to easy operation and smooth funtioning all as directed by the Engr-in-Charge.. Note:- The Spare parts will be measured and paid for separately and rate quoted is deemed to include for fixing of spare parts complete all as specified and directed. |
| 36 | M & L Water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100m & n.exc.250m. (b) M&L For 20-25 mm thick plastering in cement mortar 1:4 finished even & smooth. (c) M&L For 10-15 mm thick screed bed in 1:6 finished even and smooth. (d) Preparing & cleaning of fully dried cement plastered surface. (e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384 (f) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (g) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab. |
| 37 | E/M WORKS :Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,sunken type box etc.and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed. |
| 38 | Taking down carefully old unsv MCB DBs any type and size by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. Please Enable Macros to View BoQ information |
| 39 | Taking down carefully old unsv MCB DBs any type and size by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. Please Enable Macros to View BoQ information |