| 1 | Demolition of brick work, stone/boulder masonry built in cement mortar complete all as specified and directed. |
| 2 | Demolition of cement concrete in ground floor and paving n.exc 15cm thickness (below & above GL) unreinforced complete all as specified and directed. |
| 3 | M&L for PCC 1:4:8 Type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 4 | M&L Brickwork with subclass ‘B’ bricks old size, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 CM complete all as specified and directed. |
| 5 | M&L Brickwork with subclass ‘B’ bricks old size, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 CM except Brick complete all as specified and directed. |
| 6 | M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and directed. |
| 7 | M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 except stone complete all as specified and directed. |
| 8 | M&L Cement concrete Type C2 (1:3:6) using 40 mm graded crushed stone aggregate in surface channels and drains complete all as specified and directed. |
| 9 | Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. complete all as specified and directed. |
| 10 | M&L for rendering 10 mm thick in CM ( 1:6 ) on wall/ concrete surfaces finish even and smooth without using extra cement complete all as specified and directed. |
| 11 | M & L for Rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed. |
| 12 | M & L for raised pointing to random rubble masnoary in CM 1:4 etc complete all as specified and directed. |
| 13 | M&L for Two coat of white wash on newly plastered surface on wall including preparation of surface complete all as specified and as directed. |
| 14 | Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spot, moulds, moss and efflorescent salts, trading oil, greasy spots etc and applying with applicator one coat of white wash on walls after filling any hole with putty complete all as specified and directed. |
| 15 | M & L for Providing, cement concrete Type B-0 1:2:4 (12.5mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 16 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 17 | M & L for Per- cast cement concrete M-15 (1:2:4 nominal mix ) type B-I, (Using 20mm grade stone agg) set in cement mortar 1:4 as in manhole cover all complete all as specified and directed. |
| 18 | S & F TMT MS bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | S & F Mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to E-165 (Fe-290) complete all as specified and directed. |
| 20 | M & L PCC 1:3:6 type C2 (75 mm thick as in plinth protection & finishing the surface even & fair without using extra cement complete all as specified and directed. |
| 21 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed. |
| 22 | M & L 75mm thick plain cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in Sub base of flooring / hard standing etc complete all as specified and directed. |
| 23 | M & L for sand filling 25mm thick under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 24 | M & L for machine pressed pre cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement with pigment complete all as specified and directed. |
| 25 | M & L for machine pressed pre cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and without pigment complete all as specified and directed. |
| 26 | M & L Chequered cement concrete tiles of size 30cm x 30cm x 25mm thick (with grey cement and pigments) set, jointed and pointed in neat cement slurry in floor,laid over and incl 15mm thick cement screed base in CM 1:4,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl cutting, rubbing, grinding complete all as specified and directed. |
| 27 | M & L Chequered cement concrete tiles of size 30cm x 30cm x 25mm thick (with grey cement and pigments) set, jointed and pointed in neat cement slurry in floor,laid over and incl 15mm thick cement screed base in CM 1:4,laid and jointed with grey cement slurry mixed without pigment to match the shade of the slab incl cutting, rubbing, grinding complete all as specified and directed. |
| 28 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 29 | Reinforced cement concrete Type B1 1:2:4 (Nominal Mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like (20 mm graded aggregate) complete all as specified and directed. |
| 30 | S&F Reinforced concrete pipes,250mm dia class NP2, laid and jointed complete with collars complete all as specified and directed. |
| 31 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 32 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 33 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 34 | Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spot, moulds, moss and efflorescent salts, trading oil, greasy spots etc and applying one coat of cement base paint on walls (upto three storeyed bldgs) complete all as specified and directed. |
| 35 | Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spot, moulds, moss and efflorescent salts, trading oil, greasy spots etc and applying two coat of cement base paint on walls (upto three storeyed bldgs) complete all as specified and directed. |
| 36 | Dismantling Plain or Corrugated steel sheeting, any guge, thickness in roof covering and removing from site of work complete all as specified and directed. |
| 37 | S&F mild steel trusses (framed) purlins, rafters, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel or flat sections)including distance pieces, cleats etc conforming to Fe-410-W Gde- E- 250 (qualaity B) complete all as specified and directed. |
| 38 | S& F 0.50mm thick Pre painted galvalume alluminium zinc coating GI based corrugated steel sheeting with colour having tensile strength 550Mpa as in roof covering /Cladding to wall fixed with self tapping screws as specified complete all as specified and directed. |
| 39 | S & F Pre-painted galvalume aluminium zinc coatingn GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley gutter, drip and straight flashing fixed with self tapping screws complete all as specified and directed. |
| 40 | Preparing new steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a priming coat of red oxide complete all as specified and directed. |
| 41 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 42 | Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified and directed. |
| 43 | Dismantling cast-iron/PVC pipes including fittings taking out of trenches or walls as required dia of pipe upto 110mm complete all as specified and directed. |
| 44 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore complete all as specified and directed. |
| 45 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75mm bore complete all as specified and directed. |
| 46 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 110mm bore complete all as specified and directed. |
| 47 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 75mm bore complete all as specified and directed. |
| 48 | S&F PVC (SWR) Bends any radius for 110mm bore complete all as specified and directed. |
| 49 | S&F PVC (SWR) Bends any radius for 75mm bore with oval access door complete all as specified and directed. |
| 50 | S&F PVC (SWR) vent cowl 75mm complete all as specified and directed. |
| 51 | M&L for preparation of plaster and unplaster surface Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on walls over 2mm thick plaster of paris putty as specified and directed.Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.The acrylic emulsion paint work shall be carried out by using smart painting tools and techniques as specified in Particular Specifications and Contractor will have to produce necessary documents for purchase of smart painting tools or rent receipt of these tools along with bill/RAR.The bidders are requested take this aspect in consideration before quoting their rate and no clain on account of misunderstanding or otherwise shall be admissible on this account. Please Enable Macros to View BoQ information |