| 1 | Point Wiring |
| 2 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 3 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 4 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 5 | 1.55.1:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 6 | 1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 7 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 8 | Conduits |
| 9 | 90.1.1.1:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm |
| 10 | 90.1.1.2:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm |
| 11 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 12 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 13 | OD289889/2025-2026:Supply and fixing of Conduit Adaptor Male PVC Lock Nut 20/25mm Hole Dia Seal Connect for Conduit Box that connects the pipes and the electrical boxes. With glue to one end of the conduit, connect the conduit and the adapter and tighten the lock nut to the mounting hole of the bottom box. Made of PVC material, the adapter is waterproof, corrosion resistant, and flame retardant. |
| 14 | OD289890/2025-2026:Supply and fixing of flexible conduit of the following size, as required - 20mm |
| 15 | Sub-Circuit Wiring |
| 16 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 17 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 18 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 19 | Switches and Sockets |
| 20 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 21 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 22 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 23 | OD51649/2026-2027:Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc as required. 18Module |
| 24 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 25 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 26 | 1.57:Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. lCD |
| 27 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 28 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 29 | 2.4.3:Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way(4+24), Double door |
| 30 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 31 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 32 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 33 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 34 | 2.24.3:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB |
| 35 | Cabling |
| 36 | 90.12.6.40:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm |
| 37 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 38 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 39 | OD4258/2026-2027:Supply, laying and fixing of following DWC pipe on wall surface for the protection of cables with MS clamp 25x3 (painted) - 50/38mm. |
| 40 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 41 | OD4263/2026-2027:Supply and fixing of copper grounding clips (shim) 60 mm long x 12 mm wide x 1 mm thick for single compression glands for 4sqmm to 16sqmm cables. |
| 42 | 90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm |
| 43 | 90.12.24.1:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.2.5 sq mm |
| 44 | OD4291/2026-2027:Supply and fixing of Waterproof Adjustable 4-8mm Cable Glands made from high-level tensile strength & toughness PA66 material, which is effectively resistant to salt water, weak acid, UV, alcohol, oil, etc., and can provide long time protection for indoor and outdoor applications with IP68 rating. |
| 45 | Grounding |
| 46 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 47 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 48 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 49 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 50 | Inventories |
| 51 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 52 | OD4270/2026-2027:Supply, fixing and installation of PVC Waterproof Bulkhead outdoor type with B22 Holder (Regular Pin Type) for Which LED Bulb Easily Available in Market. (Bulb not Included) Color: White (Approved make by CPWD/KPWD/KSCADC) |
| 53 | OD4271/2026-2027:Supply and fixing of B22 LED Cool Day White LED Bulb - 9W. (Approved make by CPWD/KPWD/KSCADC) |
| 54 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 55 | 90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps |
| 56 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 57 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 58 | 90.4.10:Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 59 | OD4269/2026-2027:Supply of 150mm sweep Light Duty Exhaust fan in plastic body with self-opening lowers working on 230V single phase A/C. Approved make by CPWD/KPWD/KSCADC. |
| 60 | OD4272/2026-2027:Supply of Nylon Yellow Borewell Submersible Danile Rope for hanging the submersible pump in an open/bore well. Made by Nylon braided cotton material helps it to remain extra strong at the same time being rust free. High strength and shock resistant to abrasion and deterioration UV light resistant Unaffected by hard water Minimal elongation - 20mm (Approved make by CPWD/KPWD/KSCADC) |
| 61 | OD4273/2026-2027:Supply and fixing of waterproof submersible tape 1inch X 1feet. |
| 62 | OD4274/2026-2027:Supply and laying of HDPE pipe of size 1 1/4" 6kG in the existing RCC/Hume/Metal pipe/ DWC pipe as required. Including giving end connections (Hycount or equivalent make approved by PWD/KSCADC) |
| 63 | OD4275/2026-2027:Supply and installation of 1HP, single phase 240V, 92mm, star rated, oil cooled, 11 Stage and water Filled Submersible Pump suitable for bore well with 1.1/4", head range of 21M to 60M, Discharge of 100 to LpM, 85LpM @38M including 1HP, control panel with VM, AM, 36µf capacitor, 80-100µf starting capacitor, 2pole contactor and MCB (Model:- Lubi LDS 8HR 11 stage, Kirloskar or equivalent make approved by CPWD/KPWD/KSCADC |
| 64 | OD4276/2026-2027:Supply and fixing of Cable Junction Boxes IP 66 with integrated membranes / metric knockouts for cable entry with terminals for size (2.5sqmm to 6sqmm). (Make: Hensel - DK 1006 G or equivalent make approved by CPWD/KPWD/KSCADC) |
| 65 | OD34076/2026-2027:Supply, fixing and commissioning of 4", 1X20W LED tube light in plastic frame body with stainless steel clips and stainless screws, as required. (Approved by KSCADC/PWD) |
| 66 | EM Box |
| 67 | OD4280/2026-2027:Supply and installation of weatherproof single/three phase Energy meter box with provision for HRC fuses - 3Nos/1No.., Neutral Link - 1No. and a 4P/DP isolator, made in fiber. Double Door. Including all accessories for installation. Approved Make by CPWD/KPWD/KSCADC |
| 68 | OD4278/2026-2027:Supply and fixing of 2 Way neutral links mounted on DMC/SMC base - 32A |
| 69 | OD4279/2026-2027:Supply and fixing of HRC Fuse Base with HRC Fuse link - 32A |
| 70 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 71 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 72 | Fire and Safety |
| 73 | OD34095/2026-2027:Supply and providing First Aid Box with following first aid medicines and accessories, suitable for 10 persons, 3 Partitions with Front glass/acrylic for medicines organize with lock and 2 set of keys and Top side handle for carry to anywhere and also Wall Mountable. 1) First Aid Book 2) Antiseptic Cream 10gm 3) Antiseptic Lotion 50ml 4) Tweezer Plastic 5) Sterile Burn Dressing 10cm 5) Sterile Adhesive Plaster 6x10cm 6) Scissor 7cm 7) Dusting Powder 10gm 8) Absorbent Cotton 20gms 9) Elastic Gauze Bandage 6x1M 10) Adhesive Plaster 19x72mm - 5pcs 11) Adhesive Plaster 25x72mm - 3pcs 12) Adhesive Plaster Round - 2pcs 13) Wound Cleaning Wipes - Alcohol - 2pcs 14) Sterile Gauze Swab 10cm - 2pcs 15) Sterile Gauze Swab 7.5cm - 2pcs 16) Safety Pin - 10pcs 16)Triangular Bandage 17) Sterile Dressing Medium 18) Tincture Iodine 20ml 19) Microporous Tape 1.25x5M 20) Instant Cool Pack 21) Tourniquet 22) CPR Mouth Barrier 23) Electrolyte Powder 4.2gm - 2pcs 24) Sterile Eye Pad Oval - 2pcs 25) Sugar Sachet - 3pcs 25) Common Salt Sachet - 3pcs |
| 74 | OD34096/2026-2027:Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision. |
| 75 | OD34097/2026-2027:Supply, fixing and installation of ABC Powder Type 6 Kg Fire Extinguisher (Red and Black) effective for all types of fire like Class A, B and C types of fires as well as Electrical fires and also ABC Powder Type (Stored Pressure) Fire Extinguisher, Multipurpose uses with 1 Wall Hook and 1 Discharge Pipe. ISI, ISO and CE Certified Product and Multipurpose Uses ABC Type fire extinguisher 6 Kg with 5 years Warranty. (Approved make by CPWD/KPWD/KSCADC) Please Enable Macros to View BoQ information |