| 1 | Excavation in post holes ( or similar holes) in hard/dense soil each n.exc 0.5 cum , getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer n.exc 25cm complete all as specified and directed |
| 2 | Material and labour cement concrete type C2 1:3:6 ( 40mm graded aggregate) as in foundations, filling and mass-concrete complete all as specified and directed |
| 3 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard dense soil complete all as specified and directed |
| 4 | Exacavation in trenches in hard dense soil , n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, wells, manholes etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out in hard dense soil complete all as specified and directed |
| 5 | Material and labour for cement concrete in foundations, filling and mass-concrete using type D2 1:4:8 (40mm graded aggregate) complete all as specified and directed |
| 6 | Material and labour pre-cast cementconcrete block masonry with solid blocks, exc. 10cm in width and setting in mortar,complete Type C 1 1:3:6 set in CM 1:6 complete all as specified and directed |
| 7 | Material and labour rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces incl finished even and smooth without using extra cement complete all as specified and directed |
| 8 | Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed |
| 9 | Material and labour hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n exc 15cm thick broken stone or boulders , water and rammed to a true surface complete all as specified and directed |
| 10 | Material and labour for 75 mm thick PCC 1:4:8 Type D2 40mm graged aggregate as in sub base floor complete all as specified and directed |
| 11 | Material and labour 50mm thick cement concrete type B1 1:2:4 ( 20mm graded aggregate) as in floor, finishing cement concrete surface fair and even without using extra cement complete all as specified and directed |
| 12 | Material and labour 3mm thick 38mm wide glass dividing strip inserted in position complete all as specified and directed |
| 13 | Material and labour machine pressed precast concrete coloured interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thick M-35 grade etc complete with grey cement and pigment complete all as specified and directed |
| 14 | Material and labour for filling for 12.5mm graded coarse aggregate cushing of paver tiles with spreading and levelling in layers n exc. 25 cm thick in each layer complete all as specified and directed |
| 15 | Material and labour providing, cement concrete type B-1, 1:2:4 (20mm graded aggregate)as in hunching, coping , benching etc complete all as specified and directed |
| 16 | Material and labour per cast RCC type B1 1:2:4 (20mm graded agg) but in landings, cover slabs set in CM 1:4 (for man holes etc.)and similar articles with plain faces complete all as specified and directed |
| 17 | Material and labour mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 18 | Supply and fix steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240 complete all as specified directed. |
| 19 | Supply and fix pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/cladding to all, fixed with self tapping screws complete all as specified and directed |
| 20 | Material and labour preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed |
| 21 | Supply & fix in repairs PVC eaves gutter heavy duty half round 200mm dia including drop end with all necessary flat iron fitting complete all as specified and directed. |
| 22 | Removing excavated material exe 250m but n exc. 500m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 23 | Material and labour for excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for laying of pipes, cables, etc. getting out soft/loose soil complete all as specified and directed |
| 24 | Material and labour for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed |
| 25 | Material and labour for removing excavated soil n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed |
| 26 | Material and labour for supply,spreading and levelling clean dry sand in trenches all as specified for cable protection complete all as specified and directed |
| 27 | Supplying and laying unreinforced precast concrete cable cover, class LV, type 1, flat, size 250 x 150 x 40 mm, complete all as specified and directed |
| 28 | Supply and laying XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core complete all as specified and directed |
| 29 | Supply and fix sheet metal enclosures single door for DBs SPN 4 way,240V complete all as specified and directed |
| 30 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and directed |
| 31 | Supply and fix 240v, 10KA 'B' curve MCB of single poles and current carrying capacity 06 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed |
| 32 | Material and labour for one light point wiring on surface/ceiling /Trusses/ concealed controlled by one switch with PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 sq. mm size in PVC conduit complete all as specified and directed |
| 33 | Supply and fix LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tubelight connecting up with three core felxible copper conductor cable of suitable size from ceiling rose complete all as specified and directed |
| 34 | Supply and fix ceiling rose,3 phase/PVC/polycarbonate, isolated body complete all as specified and directed |
| 35 | Supply and fix switch piano, flush type single pole, one way 06 Amp complete all as specified and directed |
| 36 | Material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed. Please Enable Macros to View BoQ information |