| 1 | Dismantling structural steel work including doors, gates but excluding framed truss etc |
| 2 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 3 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar |
| 4 | Demolition of unreinforced cement Concrete of any description and in any position not otherwise specifically provided. |
| 5 | Earth work excavation hard/dense soil over areas not exceeding 1.5 m deep and getting out. |
| 6 | M&L for sand filling under floors or in foundations including watering and consolidation. |
| 7 | M&L for P.C.C 1:4:8 type D2 using 40mm graded aggregate for foundations, filling and mass concrete. |
| 8 | S & F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, Bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 9 | S&F of mild steel bars 6 to 8 mm dia TMT bars dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips . |
| 10 | M & L for flat Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter add for fair finished surface |
| 11 | M & L for M20 grade Concrete in Foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 12 | M & L for concrete in foundations, filling and mass concrete type B1 1:2:4 using 20mm graded aggregate. |
| 13 | Forming dummy/contraction joint with an initial saw cut of 3 mm soon after the concrete has set, upto a depth of 1/3rd to 1/4th the thickness of the slab. Widening the first saw cut to 6 mm and 24 mm deep by using diamond bit cutter of appropriate size. straight and smooth edges. Joint cleaned throughly with application of compressed air. Joint shall be made dry, vaccum cleaned and free of dirt, Oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell, medium density, crossed linked polyethylene foam backup rod of 8 mm dia. application of bond braker tape on the top of backup rod of complete width of the joint and filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) OF +/- 30% having minimum 10 year performance guarantee. Applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manfacturer complete as specified and directed. |
| 14 | Material & Labour for Brickwork built in CM 1:6 using subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius |
| 15 | Material & labour for plastering in CM 1:4 15 mm thick on fair faces of brickwork including all by works |
| 16 | M & L for cement plastering in CM 1:4 10mm thick on fair faces of brick work or concrete surfaces. |
| 17 | M & L for Structural steel of Fe 410-W (Grade E 250) Quality A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 18 | S & F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded |
| 19 | S & F of 5.5mm Sheet glass, ordinary quality and glazing with oil putty in square exceeding 0.5 sq. m in each pane |
| 20 | S & F of Welded steel wire fabric weight per square meter not exceeding 4 kgs supplied and fixed complete to wood or steel members |
| 21 | S & F of 0.63mm thickness Plain, galvanised, mild steel Sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 |
| 22 | S&F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 23 | M & L for machine profile forming of Plain, Galvanised, mild steel sheeting of any thickness for the forming of semi circular shed. The profile shall be made as per the requirement at site. |
| 24 | Supply and fixing of mild steel flat 50mm width and 6mm thick on the existing roof surfaces including cutting to shape, drilling holes for fixing 'J' bolts 2 Nos per rafter (each one on both sides of each rafter, the rafter spacing is 4.00 meters) and the remaining distance between each rafter shall be fixed with self drilling/ self tapping anti corrosive screws (not less than 2 nos per RM of 55mm length screws) with EDPM seal and screw heads shall be applied with MS polymer (modified selaine) based sealant/ adhesive to seal drilling holes in MS flat/ Galvalume sheet. Complete all as directed by EIC. |
| 25 | M & L for painting to steel surfaces of any description, over 10cm in width or girth,with two coats of synthetic enamel paint over a coat of red oxide primer including preparing new surfaces. |
| 26 | M & L for painting to steel surfaces of any description, over 10cm in width or girth,with two coats of synthetic enamel paint over a coat of red oxide primer including preparing old surfaces. |
| 27 | M&L for applying two coats of plastic emulsion paint with one coat primer on internal& exterior wall and new painted surfaces of any description over 10cm grith or width ,not othewise described all complete including preparation of new surface. |
| 28 | Removing excavated material rocks exceeding 1.50 km but not exceeding 5 km and depositing where directed. |
| 29 | Removal of excavated soil exceeding 250 m but not exceeding 500 m and depositing where directed |
| 30 | Supply & fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps MCB . (Make: Legrand / Havells /Anchor) or suitable equivalent make |
| 31 | Supply & fixing of sheet metal enclosures for DBs when MCBs to be used Single pole & neutral,12 way double door, 240 V. |
| 32 | Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. TP 25 To 63 AMP (Make: ABB/Legrand/ Havells/Hager) or suitably equivalent make. |
| 33 | Supply and fixing amp rating 240 V 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 34 | Supply & fixing amp rating 240 Volt,10KA 'C' curve MCB of single pole 6 to 32Amps in the MCB DB complete with connection testing and commissioning. (Make Legrand/Havells/C&S) or suitable equivalent make |
| 35 | Supply & Fixing of wiring for circuit/sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in STEEL conduit (Make : Havells/Finolex/Orbit /Policab) or Suitably equivalent a) 4x2.5 sqmm + 1x2.5 sqmm earth wire |
| 36 | Material & labour for .XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 core /16 sq.mm , U.G. cable with XLPE insulated aluminum conductor. (Make : Havells/ Finolex/ Orbit / Polycab) or Suitably equivalent |
| 37 | Supply and fixing LED Flood light fitting 70 Watt 230 V AC outdoor type high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. (Make: Havells/ Philips/ Wipro/ Bajaj/ CG/ Luker) or suitably equivalent make Please Enable Macros to View BoQ information |