| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge. |
| 2 | In Cement mortar |
| 3 | Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete excluding plastering of the jambs, sills and soffits. |
| 4 | 50 mm thick |
| 5 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 6 | Repairing to plaster of thickness 12mm to 20mm in patches of area 2.5sqm and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead. |
| 7 | 14.1.2 With cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 8 | Renewing glass panes with putty and nails wherever necessary. |
| 9 | 14.5.1. Float glass panes of thickness 4mm. |
| 10 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 11 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 12 | 13.31.1 Water thinnable cement primer |
| 13 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade |
| 14 | 13.29.1 New work (two or more coats) over and including priming coat with cement primer:- |
| 15 | Finishing walls with texured exterior paint of required shade: |
| 16 | 13.33.1 New work (two or more coats applied @ 3.28 ltr/10sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 18 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 19 | 9.63.1 300x16 mm |
| 20 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 21 | 9.64.1 300x10 mm |
| 22 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 23 | 9.66.1 125 mm |
| 24 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 25 | 9.62.1 125x75x4 mm |
| 26 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctionc, at top, bottom and sides with required EPDM rubber/Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling CP brass, stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately). |
| 27 | 18.1.1 For fixed portion. |
| 28 | 18.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron). |
| 29 | 18.1.2 For shutter of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately). |
| 30 | 18.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron). |
| 31 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item). |
| 32 | 18.3.1 With float glass panes of 5.50 mm thickness. |
| 33 | Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. |
| 34 | 18.6.1 Upto 5mm depth and 5mm width. |
| 35 | Providing and fixing curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with CP brass screws and wooden plugs etc., wherever necessary complete. |
| 36 | 9.19.3 20mm dia. |
| 37 | Painting top of roofs with bitumen of approved quality at 17kg per 10sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete. |
| 38 | 12.15.1 With residual type petroleum bitumen of penetration 80/100. Please Enable Macros to View BoQ information |