| 1 | General Notes 1. All the samples of materials which are to be used shall be approved by the department in advance. 2. The contractor shall comply with the provision of the Payment of Wages act 3. Rates quoted shall be inclusive of all cost of materials, labour, carriage, taxes, GST, labourcess, water charges, elctricity charges, seignorage charges, wastages etc.. 5. Rates quoted shall be excluding the amount of EPFO and ESIC contributions. EPFO and ESIC contributions are reimbursable on production of valid proof of payment made by the contractor as per CPWD norms. 6. The above mentioned rooms in the subject work will be handed over in phase manner during execution of subject work as the rooms are occupied |
| 2 | Civil items |
| 3 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as required, all complete as per the direction of the Engineer-in-charge. |
| 4 | Dismantling tile work of thickness of tiles 10 mm to 25 mm in floors including skirting laid in cement mortar and Carpets /PVC Mat laid over floor/Wall Paper iincluding stacking material within 50 metres lead as per the direction of the Engineer-in-charge. |
| 5 | Taking out existing wooden/Aluminium door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 6 | Providing sun control film to the window glass panes of best quality approved make and colour including cutting into sizes fixing in position complete complete with cost of materials, labour, scaffolding, tools and plants all as per specifications and directions of Engineer-in-charge. |
| 7 | Providing and fixing 15 mm thick tegular edged light weight calcium silicate false ceiling tiles.at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 8 | Replacement of Existing fixing false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on existing frame .The workshall be carried out as per directions of the Engineer-in-Charge. |
| 9 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 10 | Providing and laying double charge Vitrified tiles in floor with 600mm x 600mm size (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) complete as directed by the Engineer-in-charge. |
| 11 | Providing & fixing Roller blinds of approved design of approved make. The system shall be chain operated roller system utilising a bi directional wrap spring clutch. Fabric shall be attached to the tube with an adhesive strip. Roller tube shall be extruded aluminum having thickness 1.50 mm and end plugs shall be spring loaded for easier installation complete with removing existing vertical blinds, cost of material, labour, transportaion, and as per specifications and as directed by the Engineer in Charge. |
| 12 | Removing white or colour wash, distemper, wall paper, external paint by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete all as directed at site including scaffolding, cleaning of the areas.as per specifications and as directed by the Engineer in Charge. |
| 13 | Wall painting with premium acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. The rates also includes preparation of sufaces, filling with putty if required, scaffolding complete as per specifications and as directed by the Engineer-in-charge. |
| 14 | Providing and Painting two coats of synthetic enamel paint on Steel Surfaces of approved brand and manufacture to give an even shade without primer coat.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge. |
| 15 | Brick work with common burnt clay FPS (Non- Modular) bricks of class designation 7.5 in superstructure above plinth level up to floor five level in all shape & size in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | Providing and applying 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand): as directed by the Engineer-in-charge. |
| 17 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as directed by the Engineer-in-charge. |
| 18 | Providing, fabricating & fixing openable shutters/table top made up of 12 mm thick plywood (green club/equivalent) conforms to IS 659 exterior grade, BWR board & termite proof having high dimensional stability including 1 mm thick lamination with one side decorative of approved quality shade & colour and other side balancing lamination grade 1, exterior grade IS 12823 marked. The edges of the shutters shall be lipped with matching PVC edge binding tape of approved quality including necessary synthetic resin hot pressed to edges on binding machine, including approved magnet catcher SS 304 handles for each shutters. The cost includes all materials, labour charges, tools, adhesive SH, synthetic resin,lipping tape, nails, screws, etc. all complete and as instructed by the Engineer-in charge. |
| 19 | Providing, fabricating & fixing openable shutters/table top made up of 18 mm thick plywood (green club/equivalent) conforms to IS 659 exterior grade, BWR board & termite proof having high dimensional stability including 1 mm thick lamination with one side decorative of approved quality shade & colour and other side balancing lamination grade 1, exterior grade IS 12823 marked. The edges of the shutters shall be lipped with matching PVC edge binding tape of approved quality including necessary synthetic resin hot pressed to edges on binding machine, including approved magnet catcher (one pair), SS 304 handles for each shutters. The cost includes all materials, labour charges, tools, approved special quality chromium plated brass cupboard locks, adhesive SH, synthetic resin,lipping tape, nails, screws, (excluding concealed hinges which shall be paid seperately under the respective item),etc. all complete and as instructed by the Engineer-in charge. |
| 20 | Providing, fabricating & fixing frames for openable/ sliding shutters/table top made up of 25 mm thick plywood (green club/equivalent) conforms to IS 659 exterior grade, BWR board & termite proof having high dimensional stability including 1 mm thick lamination with one side decorative of approved quality shade & colour and other side balancing lamination grade 1, exterior grade IS 12823 marked. The edges of the shutters shall be lipped with matching PVC edge binding tape of approved quality including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per specification and direction of E-I-C. |
| 21 | Providing fabricating and fixing 19 mm thick Sliding shutters/partitions for cup boards, comprising of following details and as per drawing & as directed by the Engineer-in-charge. Fabricating sliding shutters of required size made of 19 mm thick block board (green club/equivalent ) conforms to IS 659 exterior grade, BWR board & termite proof having high dimensional stability including 1 mm thick lamination with one side decorative of approved quality shade & colour and other side balancing lamination grade 1, exterior grade IS 12823 marked. The edges of the shutters shall be lipped with matching PVC edge binding tape 2.00 mm thick of approved quality including necessary synthetic resin hot pressed to edges on binding machine, including fixing of the sliding system to the shutter ( sliding system shall be paid separately in the relvant item ) The cost includes all materials, labour charges, tools, adhesive SH, synthetic resin,lipping tape, nails, screws, etc. complete all as instructed by the Engineer-in charge. Providing & fixing one pair of door bend adjustment rod fitings vertically for each shutters against the warping of shutters Providing and fixing self adhesive brush sealing strip ( 2500 mm long ) at the outer vertical edges of each sliding shutter to fill the gap between the shutters in locked position. Providing and fixing approved special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws per sliding shutters including approved 300 mm long SS handles per sliding shutters. |
| 22 | Providing and fixing aluminium tower bolts of size 200x10 mm ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete as directed by the Engineer-in-charge. |
| 23 | Providing and fixing bright finished 125 mm brass handles with screws etc. complete as directed by the Engineer-in-charge. |
| 24 | Providing and fixing premium quality Top line L advanced heavy duty SLIDING SYSTEM of approved make viz. Hettich/Hafale/equivalent make for 3000 mm track to accommodate for 3 sliding doors having carrying capacity of each door weight upto 50 KG (Max Door Dimension : Height 2600mm & width 550-1500mm) with silent system soft closing for 3 door including the 3 door runner set, guide set & fixing material for door thickness 18-30mm and 3000mm Runner profile and Guide profile with all the necessary complete kits, including cost of all materials labour, tools,transport, etc. complete all as per instruction and direction of Engineer in charge. |
| 25 | Providing and fixing stainless steel soft closing Concealed hinge having wide opening angle upto 165 degree (Zero protrusion hinge) with intergrated silent system with clip on installation, consists of base 12.5 (crank 0) with mounting plate of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 26 | Dismantling wooden boardings /plywood of Thickness above 10 mm up to 25 mm in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead as per specification and direction of E-I-C. |
| 27 | Providing and fixing chromium plated brass butt hinges 75x65x4 mm (heavy type) with necessary chromium plated brass screws etc. complete. |
| 28 | Shifting of furnitures such as tables, chair, book shelves, etc. from the room to corridor before start the work and after completion of work same furniture will be shifted to room. Note: Files, computer disconnection, removal of files from almirah will be done departmentally. |
| 29 | Supplying, and fixing in position 1mm thick decorative lamination sheet (after removing existing lamination) of approved shade and colour manufactured by M/s Greenlam on M/s Silicone or equivalent approved make including fixing either single or two or more pieces in combination different colour/pattern to the plywood with Synthetic Resign of fevicol and cleaning the surface all complete with cost of materials, labour, tools plants, scaffolding all as per specifications and directions of Engineer-in-charge. |
| 30 | Renewing glass panes Frosted glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm), with putty and nails wherever necessary including racking out the old putty as per direction of E-I-C. |
| 31 | Electrical items General Notes: 1.Before quoting, the bidder shall visit the site and make himself familiar with the site, nature, conditions and quantum / scope of work involved. 2. The work mentioned in Schedule has to be done at 4th floor of B-block, AMD Office complex. In any case lift shall not be permitted to be used by the contractor’s people for carrying LT Panels during the execution of work. All the required materials shall be carried manually through staircase.3. All the samples of materials which are to be incorporated in the work shall be of reputed make & got approved by the Engineer -In- charge well in advance. 4.The rates quoted shall include cost of all materials, labour, scaffolding, transportation, hoisting, tools, tackles & installation including GST,EPF, ESI etc. as per labour act and other charges if any. No extra payment over and above the rate quoted shall be made to the contractor in this respect.5.Contractor has to pay minimum wages, EPF & ESI to the manpower deployed for the work as per state/ central government orders issued from time to time.6. The workers employed for the work shall strictly follow all safety measures as stated in safety code of this tender and also as per DAE safety code.7. The contractor shall ensure that all the persons executing the electrical work have valid electrical license.8.The contractor shall adhere to the provisions of applicable labour laws such as Contract Labour ( Regulation & Abolition) Act, 1970, Minimum Wages Act, 1948, Employees State Insurance Act, Equal Remuneration Act, 1970 and rule made there under.9. Since the work is to be done in the existing laboratory premises, removing old panels and installation of new panels is required to be done on holidays only. 10. Required tests as per IS shall be carried out by the contractor in presence of departmental respresentative at manufacturers works/ site at his own cost. The rate quoted by the contractor shall deemed to have included the testing charges. Department will not pay any extra amount towards testing charges. |
| 32 | 11. All 16 A sockets outlets should be with 6 pin & shutter type.12. All wires shall be of 1.1 KV grade FRLS PVC insulated multi stranded copper conductor wire of reputed make and departmental approved.13. Minimum size of the FRLS insulated copper earth wire continuity shall be 2.5 Sq.mm if not mentioned specifically.14. The colour shade of switches & cover plates shall be got approved from department.15. Colour coding of wires/cables should be strictly followed.16. The wiring diagrams shall be got approved from Department well before start of the work.17. Connections shall be done with the crimped type tinned copper lugs.18. Temporary power supply during nights shall be arranged if required during the execution of work. |
| 33 | Dismantling of the floor mounting type medium voltage (415V) electrical power distribution panel located at 4th floor, near PMSG section, A-Block made up of G.E.C make Switch Fuse Units of various capacities by disconnecting 1.1KV grade PVC insulated 4/3.5 core armored aluminum incoming, Al/ Cu outgoing wires of various sizes, power and lighing circuits from PDBs & LDBs by proper marking for easy reconnection/ retermination with the new cubicle type power panels without causing any damage to the the cables and wires, removal of existing MS conduits without damaging wires and shifting the panels & MS conduits from 4th floor to an earmarked area as per the requirement together with the cost of labour, miscellaneous items required for marking/ bunching, tools & plants complete and as per the instruction of Engineer-In-Charge.Distribution panel shall consist 1 No 63A TPN SFU incomer, 1Nos 30A TPN SFU outgoing connected to 7way TPN PDB with 21Nos HRC fuses, 1No 30A TPN SFU outgoing connected to 6 way TPN PDB with 18Nos HRC fuses, various LT cables like 3.5C X 25Sq.mm, and various aluminum/ copper wires ranging 6 Sq.mm, 4 sq.mm, 2.5Sq.mm etc in MS conduit. |
| 34 | Removal of existing wiring in rooms/ Sevice Counter/ corridor including removal of PVC/Steel Conduits, DB, Junction Box, Main wiring form MP Panel to SB, Switch boards, socket outlets, circuit/ point wiring etc (excluding Ceiling fans and Lights) after disconnection of mains and earth connections etc complete. The recess area of DB/ electrical boxes/ switch boards if any available after installing new DB/ switch boards is to be filled with cement concrete, necessary plastering & painting is to be done so as to match with the adjoining areas of wall on all sides, making the good, segregating and stacking the old removed items, including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C. |
| 35 | Removal of existing Ceiling fan/ Wall mounted fan after disconnection of power supply and earth connections etc complete, segregating and stacking the old removed items, including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C. |
| 36 | Removal of existing Tube Light/ Ceiling light after disconnection of power supply and earth connections etc complete, segregating and stacking the old removed items, including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C. |
| 37 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C Point. |
| 38 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( withoutindependent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C Point |
| 39 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 40 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 41 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 42 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 43 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 44 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required. |
| 45 | 3 X 2.5 sq. mm |
| 46 | 3 X 4 sq. mm |
| 47 | 3 X 6 sq. mm |
| 48 | Supplying and fixing of 40mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 49 | Supplying and fixing of 50mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 50 | Supply ,Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 4 core 16 Sq.mm aluminium armoured 1.1 KV grade on wall surface as required 16 sq. mm (clamped with 1mm thick saddle). |
| 51 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 16 sq. mm (28mm)size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 52 | Supplying and fixing of 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 53 | Supplying and fixing 4 way (4 + 12), Double door way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 54 | Supplying and fixing 63A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 55 | Supplying and fixing Single pole 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 56 | Supplying and fixing 40A, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 57 | Design, fabrication, inspection at factory ( stage & final inspection), supply & installation at site, testing and commissioning of medium voltage (415V), 3 phase & neutral, 50Hz, dust & vermin proof IP-42 protection floor mounting cubicle type distribution panels with 300mm ground clearence, body made up of 2.0mm thick CRCA sheet, partitions & doors with 1.60mm CRCA sheet and base with 40X40X5mm channel consiting of sleeves, SMC/DMC fiber glass reinforced bus bar supports, 3 phase voltmeter inbuilt protection with fuse/MCB protection & 3 phase ammeter inbuilt selector with resin cast CT's for metering, anadozied aluminum name plates, 25mm X 6mm continuous copper earth bus with double earth connections on each side of the board, interconnections with FRLS grade PVC insulated copper wires/ copper strips of adequate capacity, ferrule numbers, heavy duty termainal blocks, neopropene rubber gaskets for joints, painting with minimum seven tank treatment process & powder coated with approved shade, enameled danger board, necessary top & bottom plates for cable glands/ cable entries, earthing of all MCCB/ isolator units, name plate of panel incoming & outgoing etc all complete as per the specifications and technical parameters with the incoming and outgoing MCCB'S/ MCB's/ PDB's/ LDB's as detailed below. |
| 58 | Distribution panel of 4th floor (near PMSG) consisting of Incoming:1. 100A TP MCCB, 30KA with neutral link-01 No's, 2. Current transformer (Resin cast) rated 1000/5A, 10VA, Cl 1.0-03 No's, 3. 3 Ph LED Voltmeter, Cl 1.0 with inbuilt selctor switch-01 No's, 4. 3 Ph LED Ammeter, Cl 1.0 with inbuilt selctor switch-01 No's, 5. LED Type RYB indication lamps-03 No's, 6. HRC fuse/ SP MCB-03 No's. Bus bar: 200A Copper Bus bar Outgoing: 3 Nos 6 Way ((4+18) Double door DB consisting of 1. 63 A TP MCCB with neutral link-02 no's, 2. 40A TP MCB with neutral link, 10kA-01 No's, 3. 40A, 100mA, DP RCCB -06 No's, 4. 25A, 30mA, DP RCCB -03 No's, 5. 25A SP MCB, C-Curve, 10kA-12 No's,6. 20A SP MCB, C-Curve, 10kA -12 No's, 7. 6A SP MCB, C-Curve, 10kA-12 No's |
| 59 | Note:a) All MCCB's shall have breaking capacity as specified.b) All outgoing individual feeders shall have 'ON' & 'OFF' indication lamp with cluster type LED.c)FRLS wires/ MCCB's/MCB's/RCCB's shall be confirming to latest IS/IEC standards. d) RCCB's shall have 100mA/ 30mA sensitivity as specified and MCB's shall be of 'c' category unless specifically mentioned. |
| 60 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 61 | 3 Module (100mmX75mm). |
| 62 | 12 Module (125mmX125mm). |
| 63 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 64 | 5/6 amps switch |
| 65 | 15/16 A switch |
| 66 | 3 pin 5/6 A socket outlet |
| 67 | 6 pin 15/16 A socket outlet |
| 68 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 69 | Supplying and fixing of 20A, 240V, SPN industrial type socket outlet with 2 pole & earth, metal enclosed plug top along with 20A SP MCB, \\"C\\" Curve in sheet steel enclosure on surface/ in recess, with chained metallic over for the socket outlet and complete with connections, testing & commissioning etc. as required. |
| 70 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 71 | Brush Less Direct Current (BLDC) Fan without Remote: Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 72 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 ≤ 120 lm/ Watt). Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of 36 W body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range: -5deg C to 40 deg C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time(LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum powerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standard. |
| 73 | Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Please Enable Macros to View BoQ information |