| 1 | Taking down carefully aluminum/copper point wiring (light ,fan, socket any type, power, bell etc. ) complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fittings etc) and removing the material from site and making good the disturbed surfaces of walls ceiling etc complete all as directed.( Note: Credit for above items should be made as per credit Schedule separately) |
| 2 | Taking down carefully by submain wiring of any type complete and making good disturbed sufaces to match with the existing surfaces all as directed by Engineer-in-Charge. |
| 3 | Taking down old unserviceable existing SPN/TPN DBs / enclousers any size and type / any descriptions as iron sheet scrap including MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed |
| 4 | M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, 1100 volts grade copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) including with modular flush metal boxes with modular cover plates & frame for mounting modular switches, sockets, regulators etc or including sunk cast iron /pressed steel/terminal boxed for mounting flush type switches/sockets etc with 3 mm thick phenolic laminated sheet covers and including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified in current SSR Part-I & II & directed by the Engineer-in-Charge as described below:- |
| 5 | a) One light/ fan point controlled by one way switch 5 amp complete. |
| 6 | c) One 3 pin 5 Amps socket point controlled by one way switch on same board. |
| 7 | d) One 3 pin 5 Amps socket point controlled by one way switch on independent board. |
| 8 | e) One bell point controlled by one push button. |
| 9 | f) One light point controlled by two 2-way switches. |
| 10 | All as per item No. 4 but for 3 pin / 5 pin 16 Amps sockets outlet with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent Point wiring complete all as specified and as directed. |
| 11 | Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete. |
| 12 | Supply and Fixing Modular bell Push switch 6 Amps with indicator single pole one-way, 1 Module . |
| 13 | Supply and Fixing Modular switch 16 Amp single pole one way,1 Module all as specified. |
| 14 | Supply & Fixing Modular fan Regulator electronic step type complete all as specified. |
| 15 | Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps, combined 2 Module complete all as specified. |
| 16 | Supply and Fixing Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete. |
| 17 | Supply and Fixing Modular switch 6 Amps single pole two-way, 1 Module complete all as specified. |
| 18 | Supply and Fixing in replacement switch piano type , SP, one way, flush type 5 Amps complete all as specified. |
| 19 | Supply and Fixing in replacement socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified. |
| 20 | Supply and Fixing in replacement socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified. |
| 21 | Supply and Fixing in replacement switch piano type , SP, one way, flush type 15 Amps complete all as specified. |
| 22 | Supply and Fixing in replacement bell push siwtch piano flush type, SP, one way, 5 Amps complete all as specified. |
| 23 | Supply and fix in repair ceiling rose surface bakelite 65mm x 50mm three terminals complete . |
| 24 | Supply and fix in repair lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified. |
| 25 | Supply and fix in replacement mini MCB enclosure including DP 16 amp, type 'C' curve complete. |
| 26 | Supply and fix in replacement Bell Ding dong type, 230 Volts complete with connection. |
| 27 | Supply and Fixing in replacement fan Regulator piano flush type (socket type as per existing), electronic step type complete all as specified. |
| 28 | M & L for Sub Main Wiring wiring with two runs single core 2.5 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge.(Note: Two runs of 4 Sq mm (P&N), one run of 4 Sq mm earth wire & One run of PVC casing and caping will be measured as one RM). |
| 29 | All as per item no 23 but for 4 Sqmm |
| 30 | All as per item no 23 but for 6 Sqmm |
| 31 | All as per item no 23 but for 10 Sqmm |
| 32 | Supply & fixing in repair indoor decorative ultra slim surface /Wall mounted LED batten tube light complete fitting 1x 20 watt LED Tube fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply & fixing in repair indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1X9 watt LED Tube fitting (size within 600x25x40 mm) suitable for mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K,>100Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply & fix in repair surface mounted bulk head LED light fitting, IP66 protection, including 10 watt LED lamp complete with all accessories and connection complete all as specified and as directed. |
| 35 | Supply and fix LED 9 W suitable for normal holder (Base Cap B22) complete. |
| 36 | Supply and fix LED 7 W suitable for normal holder (Base Cap E14) complete. |
| 37 | Supply and install of 36W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V including all connections and fixing of bracket complete all as specified. |
| 38 | Supply & fix in repair recess type, 35/36 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete. |
| 39 | S&F in repair LED Round/square recess mounted slim downlighter 15/18 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K complete all as specified. |
| 40 | S&F in repair LED Round/square recess mounted slim downlighter 12 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K complete all as specified. |
| 41 | S&F in replacement MCB distribution board, SPN 12 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified. |
| 42 | All as per item no 36 but for SPN 8 Way |
| 43 | All as per item no 36 but for SPN 4 Way |
| 44 | Supply & fix in replacement MCB SPN 40-63 Amps,' C' series , bracking cap10KA, 240V complete. |
| 45 | Supply & fix in replacement of MCB SPN 16-32 Amps,' C' series , bracking cap 10KA, 240V complete. |
| 46 | Supply & fixing in replacement of MCB SP 6 - 32 Amps, ' C' series ,bracking cap 10KA, 240V complete. |
| 47 | Supply and fix in replacement SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Volts with all connection complete all as specified and directed. |
| 48 | Supply & fix in replacement metal clad SPN plug top 20 Amp for fixing on AC Box complete. |
| 49 | Supply and fix modular MCB DP 16 Amp, ' C' series, 240 V complete all as specified and directed. |
| 50 | S&F in repair Plastic Surface mounting box 1 / 2 module gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge. |
| 51 | S&F in repair Plastic Surface mounting box 3 / 4 module gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge. |
| 52 | S&F in repair Plastic Surface mounting box 6 / 8 module gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge. |
| 53 | Supply & replacement of 3 mm thick laminated mica sheet top cover suitable for switch board 3 way to 6 way including removing & re-fixing of existing switch / socket and complete connection all as directed.Note :- Replacement of unserviceable switch / socket / regulator shall be measured & Paid separately. |
| 54 | All as per item no 48 but for 8 way to 12 way |
| 55 | M&L for Modular metal flush box 1/2 Module complete all as specified and directed. |
| 56 | M&L for Modular metal flush box 3 Module complete all as specified and directed. |
| 57 | M&L for Modular metal flush box 4 Module complete all as specified and directed. |
| 58 | M&L for Modular metal flush box 6 Module complete all as specified and directed. |
| 59 | M&L for Modular metal flush box 8 Module complete all as specified and directed. |
| 60 | M&L for modular white cover plate with frame, 1 / 2module complete all as specified and directed. |
| 61 | M&L for modular white cover plate with frame, 3 module complete all as specified and directed. |
| 62 | M&L for modular white cover plate with frame, 4 module complete all as specified and directed. |
| 63 | M&L for modular white cover plate with frame, 6 module complete all as specified and directed. |
| 64 | M&L for modular white cover plate with frame, 8 module complete all as specified and directed. |
| 65 | M&L for point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces (making good all to the disturbed surfaces as per existing) including one run of 1.5 sqmm PVC insulated copper conductor cable green in colour for continuous earthing including gang box/2.0mm thick MS terminal box as per site requirement for fixing switches, sockets, fan regulators etc fixed to wall with 3mm thick laminated sheet top cover complete all as specified for:- |
| 66 | a) One light point/ fan point / bell point controlled by one switch |
| 67 | b) One 3 pin 5 Amps socket point controlled by one way switch on same board. |
| 68 | c) One 3 pin 5 Amps socket point controlled by one switch on independent board |
| 69 | All as per item No. 60 here-in-before but with 4.0 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4.0 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 70 | Supply and Fixing switch piano type , SP, one way, flush type 5 Amps complete all as specified. |
| 71 | Supply and Fixing socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified. |
| 72 | Supply and Fixing socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified. |
| 73 | Supply and Fixing switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified. |
| 74 | Supply and Fixing fan Regulator piano flush type, electronic step type complete all as specified. |
| 75 | Supply and Fixing in repair modular switch 6 Amps single pole one-way, 1 Module complete. |
| 76 | Supply and Fixing in repair Modular switch 16 Amp single pole one way,1 Module all as specified. |
| 77 | Supply & Fixing in repair modular fan Regulator electronic step type complete all as specified. |
| 78 | Supply and Fixing in repair modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete. |
| 79 | Supply and Fixing in repair modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete. |
| 80 | Supply and fix SP enclosure modular type, with a two pin and earth plug and socket complete with Single Pole MCB of rating 20 Amps, 240 Volts complete with all connection as directed. |
| 81 | Taking down and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). Note:- Old unservieceable item shall be deposited to E/M store yard. |
| 82 | All as per item no 73 but for 1400 mm sweep |
| 83 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor. Old unservieceable item shall be deposited to E/M store yard. |
| 84 | All as per item no 75 but for 1400 mm sweep |
| 85 | Taking down, Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300msweep with, blades, and frame and louvers . Note:- Old unservieceable item shall be deposited to E/M store yard. |
| 86 | All as per item no 77 but for 250 mm sweep |
| 87 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m |
| 88 | All as per item no 79 but for 450 mm sweep |
| 89 | S&F cable with copper conductor PVC round sheathed (Flexible) industrial cable 2.5 sqmm, 3 core |
| 90 | Supply & fixing powder coated CRCA steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted, triple pole and neutral 4 way with 100 Amps rated copper bus bar, type complete all as directed. |
| 91 | Supply & fix in replacement of MCB TPN 40 to 100 Amps,' C' series , bracking cap 10KA, 415V complete including taking down old MCBs all as specified and directed. |
| 92 | S&F TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail ,blanking Plates, cable ties for cable management, 440 V, 4 way complete all as specified including fitting suitable for MCBs with connections complete all as specified and directed.Note : -MCB & MCB /MCCB DBs shall be of same make and measured and paid seperately under respective items of Sch A. DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as pe directed & rate shall be included in the items. |
| 93 | Supply & fix in replacement of MCCB 160 Amps, breaking cap 25 KA, 4 Pole, 415V complete including taking down old MCBs all as specified and directed. |
| 94 | Supply & fix in replacement of MCCB 125 Amps, breaking cap16 KA, 4 Pole, 415V complete including taking down old MCBs all as specified and directed. |
| 95 | Supply & fix in replacement of MCCB 100 Amps,breaking cap16KA, 4 Pole, 415V complete including taking down old MCBs including taking down old MCBs all as specified and directed. |
| 96 | Supply & fixing in repair indoor wall mounted fitting, brushed nickel finishfixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts all as directed at site. Make: Phillips comet 30575 or equivalent |
| 97 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out all as specified and as directed by Engr-In-Charge. |
| 98 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified. |
| 99 | Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified. Please Enable Macros to View BoQ information |
| 100 | Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified. Please Enable Macros to View BoQ information |