| 1 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc all as specified. |
| 2 | M&L brick work with sub class B bricks straight or curved on plan 6m mean radius built in cm 1:6 all as specified. |
| 3 | All as per item above but except bricks |
| 4 | M&L for 15mm thick cement plaster in CM 1:4 on bricks or concrete surfaces finishing the surfaces even and smooth without using extra cement as directed , all as specified. Note :Rate for form work if reqd to be incl in the rate quaoted by the contractor. |
| 5 | Rendering dubbing coat over damaged irregular surface of patches at colms,chajjas,canopy and soffits, roof projections, ceiling facia etc using GI chikrn mess of size 0.25mm thick and 20 mm aperature fixed with nails including necessary scaffolding arrangement as required at site average 15mm thick in cm 1:4 over cement slurry coat thick @ 3 Kg/sqm making the surface even followed by 5mm thick rendering in CM 1:3 furnished even& smooth including applying two coats of weather proof emultion paint incl making of drip course as reqd complete incl roughening surface of old concrete by picking sweeping clean and washing with water all as specified. Note :Rate for form work if reqd to be incl in the rate quaoted by the contractor. |
| 6 | Material and Labour for exterior painting work including complete removal of existing loose paint layers till plaster level by using jet pressure washer and crack filling up to 3mm by using crack seal (Fiber glass reinforced crack filling compound) & up to 10mm by using textured crack filler (Acrylic crack filler with a grainy texture).Touch-up by using wall putty with silicon additives followed by application of one coat of truecare exterior primer on walls and chajjas and applying two coats of modified acrylic smooth emulsion exterior grade with silicon having anti-algal and dust pickup resistance properties,Material should be applied(Dilution,Recoating Period etc...) as per manufacturer instructions by using fully automatic air less spray machine having flow speed of minimum 1 ltr minute and pressure of 3300 PSI.Camouflage/colour pattern decide by the user.Note:a) The above specification is guaranteed for 4 years Performance Warranty.b) Rate of Removing of vegitation/plantation up to height of 7Mtr deemed to be included in the rate coated by contractor. |
| 7 | Rendering 15mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:6) finished even and fair without using extra cement, including taking down existing plaster all as specified and directed. |
| 8 | M&L Preparation of old plastered or unplastered surfaces of wall including cornices, pillasters by using vacum based sanding maching to remove all smoke dust,moulds,moss and efflorescent salts and removing oily and greasy spots etc applying one coat of distemper oil emulsion of shade as approved by Engr-in-charge with auto paint roller on old surfaces of walls all as specified and directed. Note- Surface to be made even and smooth by filling the depression if any. |
| 9 | Applying 2mm thick white putty on wall surfaces and rubbing the surface even and smooth all as specified and directed. |
| 10 | Dismantling wrought iron or mild steel work of any description not other wise provided for |
| 11 | Material and labour for surface excavation in any type of soil n.exc 30 cm and averaging 15cm deep including clearing away all grass vegetation, shrubs , roots and trees not exc 30cm girth complete and getting out complete all as specified and directed by Engineer-in-Charge. |
| 12 | Material and labour for excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out, returning filling and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n exc 50 m and making good surface in any type of soil complete all as specified and directed by Engineer-in-Charge. |
| 13 | Material and labour for Hardcore using broken stone boulders not exceeding 63mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surfaces complete all as specified and directed by Engineer-in-Charge. |
| 14 | Removing excavated soil material n exc 50m and depositing where directed at a level n. exc 1.50m above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete for post holes complete all as specified & directed. |
| 16 | Supply and fixing rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates and similar work,posts, conforming to Fe-410-W(Gde-250 quality B) complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and fixing for MS plated (plain or chequred ) channel, cleats, square cut or notched (ordinary and counter sunk) forming holes complete all as specified and directed by Engineer-in-Charge. |
| 18 | Steel work in hollow tubular trusses including special shaped washer (Shape-Tensile structures can be designed in verious shapes like cones,barrel vaults,or Hyperbolic paraboloids,depending on the desired aesthetic and functional requirements)etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge. |
| 19 | Dismantling any typie of sheeting in roof covering. |
| 20 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverings/cladding to wall,fixed with self tapping screws/J or L hooks incl bitumen washer wherever required all as specified. |
| 21 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverings/cladding to wall,fixed with self tapping screws as specified. |
| 22 | S&F Transparent roofing sheet commonly made of polycarbonate thickness 4mm and UV protection (co-extruded UV layer) as in roof coverings/cladding to wall,fixed with self tapping screws/J or L hooks incl bitumen washer wherever required and colour pattern decide by the usercomplete all as specified & directed by Engineer-in-Charge. |
| 23 | Refixing old asbestos cement, corrugated or semi corrugated sheets in roof, walls etc fixed with L- type or J- type or cranked hook |
| 24 | M&L for Asbestos cement two piece adjustable plain wing ridge 6 mm thick fixed with L- type or J- type or cranked hook |
| 25 | M&L for preparation of new or previously untreated steel surfaces of any description over 10 Cm width and girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified & directed by Engineer-in-Charge. |
| 26 | Material and labour for taking down existing boarding from wall/ceiling of any description complete all as specified & directed by Engineer-in-Charge. |
| 27 | Material and labour Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mmthick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to entre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material and labour Seamless calcium silicate ceiling 12mm dia made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre,including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid eparately) incl Design/colour complete all as specified and directed by Engineer-in-Charge. |
| 29 | Material and labour Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat/curved surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) |
| 30 | Supply and fixing hollow Paneling PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified & directed by Engineer-in-Charge. |
| 31 | M&L for 75mm thick cement concrete (1:3:6) type C-2, using 40mm graded agg as in plinth protection, flooring and sub base etc including finishing the surfaces even and smooth without using extra cement complete all as specified & directed. |
| 32 | M&L for 12mm thick full body vitrified single piece tiles (homogeneous) for stairs with anti skid property and having self embossed grooves (for tread portion) and its skirting in single colour set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and as directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. complete all as specified and directed by Engr-In-Charge. |
| 33 | Material and labour for non skid heavy duty designer coloured tiles as in floor for parking or other open area like flag post etc of size 400 x 400mmx 10-12mm thick in floors etc of pattern as approved by GE, set and jointed (joint free) in neat cement slurry and pointed in coloured cement. over and including screed bed or bedding layers of mortars 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified & directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |