| 1 | Supply, Installation, Testing & Commisioning of Microprocessor based addressable OPC complied fully networkable fire alarm control panel ( VDS / UL / LPCB / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 320 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store minimum 4000 log events in its memory (EPROM). The panel should have extra loop card slot for future expansion. Two Loop Panel. INTELLIGENT FIRE ALARM SYSTEM Item No-1.1 Page 1 |
| 2 | Supply, Installation, Testing & Commisioning of Microprocessor based Intelligent addressable and network connected Repeater OPC complied panel ( VDS / UL /ERTL/ LPCB/ FM approved), should have all the controls and monitoring as on the main fire alarm panel, functioning as a controller, shall allow remote command in the system reset, trouble and alarm silence and manual alarm. It shall be programmable to display information for the entire system i.e. all panels in the network, having minimum 320 characters LCD display (display system status). The system text displays shall include: Alarm missing point trouble; system test, service, local system test, extra custom test by polling circuit and address. The repeater panel should annunciate alarm and trouble conditions in the occation of signal actuation. Degree of protection as per OEM Standard. INTELLIGENT FIRE ALARM SYSTEM Item No-2 Page 1 |
| 3 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector ( VDS / UL / LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA (Note : Detectors without built-in fault isolator is also acceptable with one independent short circuit fault isolator after every four (04) detector is to be provided without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. Degree of protection as per OEM Standard. INTELLIGENT FIRE ALARM SYSTEM Item No-3 Page 1 |
| 4 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector ( VDS / UL / LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 58 deg. C to 68 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA (Note : Detectors without built-in fault isolator is also acceptable with one independent short circuit fault isolator after every four (04) detector in the loop is to be provided without extra cost) the detectors should have built in response indicator with LED indicator.Degree of protection as per OEM Standard. INTELLIGENT FIRE ALARM SYSTEM Item No-4 Page 2 |
| 5 | Supplying, installation, testing & commissioning of responseindicator on surface/recessed MS Box with metallic cover having two LED and Degree of protection as per OEM Standard etc. complete with all connections etc as required. INTELLIGENT FIRE ALARM SYSTEM Item No-7 Page 2 |
| 6 | Supply, Installation, Testing & Commissioning of Addressable Loop Powered /panel powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator as per NFPA (Note :Hooter without built-in fault isolator is also acceptable with one independent short circuit fault isolator is to be provided without extra cost). ( VDS / UL / LPCB / FM approved ) approved. Degree of protection as per OEM Standard. INTELLIGENT FIRE ALARM SYSTEM Item No-8 Page 2 |
| 7 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / LPCB / FM approved ) with in built short circuit fault isolator as per NFPA (Note : MCP without built-in fault isolator is also acceptable with one independent short circuit fault isolator is to be provided without extra cost). Degree of protection as per OEM Standard. INTELLIGENT FIRE ALARM SYSTEM Item No-9 Page 2 |
| 8 | Supply, Installation, Testing & Commissioning of Addressable Control Modules/ Relay Module ( VDS / UL / LPCB / FM approved ) for controling Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator / External fault isolator with adjustable setting parameter likes(Resistive, Inductive or capacitive) of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required. INTELLIGENT FIRE ALARM SYSTEM Item No-11 Page 2 |
| 9 | Supplying and delivery of following size Un-Armoured cables XLPE insulated are designed for 1.1 kV Stranded copper conductor and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) 2 core 1.5 sqmm Copper Un-Armoured LT Cable, XLPE, 1.1KV Grade ( Item No-3.1 Page 2) |
| 10 | Supplying and fixing RED colour PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 20 mm size [7(a)/ E-16 ] |
| 11 | Cleaning,Servicing,Checking, necessary Rectification, Testing and Re-commissioning of Intelligent Addressable Multisensor (Fixed Temp + ROR + Smoke) Detector along with Base & other necessary accesories, Manual Pull Station or Break Glass type MCP along with all necessary accessories and Hooter Cum Strobe along with all necessary accessories as per direction of EIC and as per latast Fire alarm guide line (VDS approved Siemens make fire alarm system ) (FOR PP UNIT) |
| 12 | Checking,Testing,necessary repairing and Re-Commissioning of existing Siemens make Fire alarm control panel at Main Rajbari building and connecting the existing Siemens make Fire alarm system after necessary work / rectification at OPD Building for Centralized monitoring from Rajbari building and control installed individual detector and other devices within entire hospital campus from single fire alarm panel installed at Rajbari Building. (FOR PP UNIT) |
| 13 | Supplying, Installing, Testing & Commissioning of LED technology, High efficiency, Double Sided Exit Signage cum Emergency light with Function Use either as an emergency luminaire or exit sign, Testing system Stand Alone, Housing Polycarbonate, Glow wire test: 850°C, RAL9003, Type of mounting Surface: Recessed base for ceiling, double sided cone diffuser, plexi plate diffuser, set of 3 exit legends (L, R, D), Degree of protection IP65, Operation Mode Non Maintained or Maintained & Non Maintained mode selectable, Connection voltage 230V -/+ 5% [220V-240V] 50-60Hz, Permissible ambient: temperature +5°C to +40°C, Battery: Ni-Cd, Duration 3 hours, Viewing distance 30m, Insulation class II, Dimensions for 30 m viewing distance version: 371 x 170 x 62. ( Make: Eaton/Teknoware/ADB) |
| 14 | 1. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SUPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM.2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL.3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES. Please Enable Macros to View BoQ information |