| 1 | Earthwork in excavation by mechanical means (hydraulic excavator) / manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.a) All kinds of soil |
| 2 | Earthwork in excavation by mechanical means (hydraulic excavator) / manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.b) All types of Ordinary rock including all types of laterite rock, blasting prohibited |
| 3 | Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete.b) Moorum |
| 4 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 5 | Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases for columns and mass concrete. |
| 6 | Centering and shuttering including struttings, propping etc. and removal of formwork for b) vertical surfaces such as retaining walls, return walls, walls (any thk) including attached pilasters, buttresses, plinth and string courses, fillets, etc. |
| 7 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate. 20 mm nominal size) excluding cost of centering, shuttering and finishing in:a) All works upto plinth level |
| 8 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate. 20 mm nominal size) excluding cost of centering, shuttering and finishing in:b) In retaining walls, return walls (any thk) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc, upto floor five level. |
| 9 | Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall, wing wall and earth retainig structure complete as directed by the Engineer in chargeA) 100 mm dia |
| 10 | Providing and laying filter media with Granular materials crushed stone Aggregates satisfying the rerquirement As Per Clause 2504.2.2 of MOSRT & H Specification to a thickness of 500 mm laid horizontally in layers of 250mm thick and compacted to firm condition etc. complete as direction by Engineer-in-charge. |
| 11 | Refilling the pipeline / foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 12 | Centering & shuttering including Strutting, Propping & removal of forms for :i) Foundations, Footings, Bases for columns |
| 13 | Centering & shuttering including Strutting, Propping & removal of forms for :iii) Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan) |
| 14 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size)a) All works upto plinth level |
| 15 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size)b) In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level |
| 16 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.)) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S.1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 17 | Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastner of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA6 grade sleeve, including drilling of hole in frame, concrete / masonry, etc. as per direction of Engineer..e) 10 x 160mm |
| 18 | M.S.Plates (SAIL, TATA VIZAG, JSW Steel Ltd.) |
| 19 | Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in cm. 1 : 5 (1 cement : 5 coarse sand) in foundation upto plinth level |
| 20 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 / Rectangular Hollow Section (RHS) IS4923 / Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW, APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 21 | Transportation and CarriageC) BY MANUAL LABOUR INCLUDING LOADING, UNLOADING STACKING FOR A LEAD LESS THAN 0.5Kms. Item No. Materials Unit of ratesLight Materiala) Lime, Murrum, building rubbish, earth, manure or sludge and excavated rocksi) lime, moorum, earth , building materials, rubbish |
| 22 | Transportation and CarriageC) BY MANUAL LABOUR INCLUDING LOADING, UNLOADING STACKING FOR A LEAD LESS THAN 0.5Kms. Item No. Materials Unit of ratesLight Materialb) Sand, stone aggregate and soiling.i) sand, stone agg below 40mm nominal |
| 23 | Transportation and CarriageC) BY MANUAL LABOUR INCLUDING LOADING, UNLOADING STACKING FOR A LEAD LESS THAN 0.5Kms. Item No. Materials Unit of ratesLight Materialb) Sand, stone aggregate and soiling.iii) soling stone |
| 24 | Transportation and CarriageC) BY MANUAL LABOUR INCLUDING LOADING, UNLOADING STACKING FOR A LEAD LESS THAN 0.5Kms. Item No. Materials Unit of ratesHeavy Materialsb) cement |
| 25 | Transportation and CarriageC) BY MANUAL LABOUR INCLUDING LOADING, UNLOADING STACKING FOR A LEAD LESS THAN 0.5Kms. Item No. Materials Unit of ratesHeavy Materialsc) Steel |
| 26 | a) Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 27 | Providing and fixing Prince or equivalent make PVC SWR half round eaves gutter with bolts, nuts and flat iron brackets 40 x 3 mm size complete.b) 180 mm nominal size |
| 28 | Extra for providing and fixing prince or equivalent make PVC SWR running outlet with 2 clamps for socketed half round eaves gutters.b) 180 mm nominal size |
| 29 | Extra for providing and fixing prince or equivalent make PVC SWR joint bracket with 2 clamps for socketed half round eaves gutters.b) 180 mm nominal size |
| 30 | Extra for providing and fixing prince or equivalent make PVC SWR short stop ends for socketed half round eaves guttersb) 180 mm nominal size |
| 31 | 12mm cement plaster 1:3 (1 cement : 3 fine sand) |
| 32 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
| 33 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (Such as Dulex / Asian Paints / Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 34 | Painting (two or more coats) with black anticorrosive bitumastic paint of approved brand and manufacture on new work to give an even shade. |
| 35 | Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35/M40 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer - in I, Wave, Rectangular, Square etc shapes. The products should comply to IS 15658:2006 and manfucatured by ISO 9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. c) 80 mm thick in all colours except grey (M40 grade) |
| 36 | 25 mm dia ISI marked Rigid PVC conduit (Medium) conforming to IS 9537 |
| 37 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required.(a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm Conduit) |
| 38 | Supply and erecting of 56 inch (1400mm sweep) ceiling fan, double ball bearing type, complete with all accessories.(a) Cat A |
| 39 | Installation, earthing, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm FR PVC insulated copper conductor single core cable sheet cover on the fan box etc. as required. |
| 40 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required(a) Cat A |
| 41 | Supply and erecting 'J' type Mild Steel fan hook fabricated out of 35 X 6 mm flat strip suitable for rafters complete with coach screws etc as required.(a) For 4 inches rafter size |
| 42 | Supplying and fixing extra down rod of 20 cm length GI pipe 15 cm dia heavy gauge including painting etc as required |
| 43 | Supply and installation of 50 W Flood light as required of make: Carron / Samson / Bajaj etc, or of suitable make as directed by Engineer-in-charge |
| 44 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit (medium) with modular switch, modular plates, suitablesize modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(c) Group C -- with Cat A Modular Accessories |
| 45 | 25 mm PVC junction box two way |
| 46 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.a) SP, Cat A |
| 47 | SPN, single door MCB DB, 4 way,(2+ 4 MODULE) Cat A Please Enable Macros to View BoQ information |