| 1 | Stripping off worn out plaster and raking out joints of walls, celings etc. up to any height and in any floor including removing rubbish with in a lead of 75 m as directed. . |
| 2 | Cleaning the exposed reinforcement preferably upto full diameter by wirebrush, applying two coats of polymer based rust removing compound left for24 hours, removing the coating and then applying two (2) coats of polymermodified anti corrosive protective coating formulated to inhibit the corrosionof reinforcement as per manufacturer's specification] [Mode ofmeasurement:The affected surface area of reinforcement shall beconsidered for payment] |
| 3 | (a) Applying 2 coats of bonding agent with synthetic multi functional rubberemulsion having adhesive and water proofing properties by mixing with waterin proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer'sspecification [Cement to be supplied by the Department] |
| 4 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge. |
| 5 | b) 25 mm thick |
| 6 | Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor). [Excluding cost of chipping over concrete surface]. |
| 7 | (ii) With 1:4 cement mortar . |
| 8 | (c)10 mm. thick plaster. (Add. above ground floor - 2nd floor) |
| 9 | (i) with 1:6 cement mortar. |
| 10 | (b) 20 mm. thick plaster. |
| 11 | (b) Rendring the surface of walls and ceiling with white cement based wall putty of approved make and brand (1.5mm thick). |
| 12 | Acrylic Distemper to interior wall, ceiling with a coat of solvent basedinterior grade acrylic primer (as per manufacturer's specification)including cleaning and smoothning of surface.Two Coats |
| 13 | Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter ( top rail, bottom rail, lock rail,door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS:733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM Natural white |
| 14 | Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top,bottom and side member, intermediate member , glazing clip made of Aluminium Alloy Extrusions conforming to .Natural white. |
| 15 | a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90sqm |
| 16 | Supplying bubble free float glass of approved make and brand. Conforming to IS: 2835-1987. |
| 17 | (iii) 5 mm thick clear glass. |
| 18 | Supplying fitting & fixing in position 9 mm thick Heavy Duty Cement board - Type-A (High Pressure steam cured, tested asper AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, density >1450kg/m3, Bond strength 15 N/sqmm fire resistant, termite proof, moisture resistant) reinforced with cellulose fibre manufactured through autoclaving process as per IS : 14862 &ISO 8336, with fibre cement screws in partition excluding cost of supporting structure as per drawings and direction of Engineer-in-Charge complete. (Note: The Item -26 under Section - U(Page - 247) can be used as supporting structure for internal partition ). |
| 19 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. |
| 20 | (vii) 100 mm x 58 mm x 1.90 mm. |
| 21 | (i) Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete :. |
| 22 | (b) Medium (I.S.I. size 2). |
| 23 | Anodise aluminium barred/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S.204/74 fitted and Fixed with cadmium plated screws:. |
| 24 | (iv) 150 mm long x 10 mm dia. bolt. |
| 25 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S.230/72) fitted and fixed complete:. |
| 26 | (a) With continuous plate base (hexagonal/round rod). |
| 27 | (vi) 150 mm grip x 10 mm dia rod. |
| 28 | Collapsible gate with 40 mm.X 40mm x 6 mm.Tee as top and bottom guide rail, 20 mm,X10 mm,X2 mm. vertical channels 100 mm. apart in fully stretched position 20 mm. X5 mm.M.S. flats as collapsible bracing properly rivetted and washered including 38 mm. steel rollers including locking arrangement, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls , floors etc. and making good damages complete. (Add extra @1% for each addl. floor upto 5th floor and @1.25% for each addl. floor above 5th floor.)In ground floor. . Please Enable Macros to View BoQ information |