| Sl. No. | Item Description |
| 1 | Providing EPABX System: |
| 2 | Supply, installation, testing & Commissioning of IP based EPABX exchange: The proposed IP Based EPABX System shall be based on Server Media Gateway architecture and advance unified Communication system, expandable up to 5000 Analog or IP Users. The system should be equipped with 1U Server with configuration Intel 15 Dual Core Processor, Dual Giga bit ETH Ports DDR4 8 GB RAM. 1TB SATA SSD, Support End points -IP phones, Analog Phones & Video Phones). VPN Server & Client Should be Built-in in the solution. Voice Mail & Voice Mail to Email for all users should be inbuilt in the system. The system should Support IPV4 & IPV6 from Day one. The system should support Redundant Server for High Availability which can be added at a later date. The Operator console and PBX should be from same OEM. The operator console should have 4.3\\"480x272 main color display and 2x3.5\\" 320x480 side color displays for DSS keys which delivere high-definition audio, wide band audio support, with advanced noise-cancellation feature for crystal- clearHD voice quality and feature advanced acoustic echo cancellation to minimize background noise.6-wayconference call, Buit in Bluetooth, Full-duplex hands-free speakerphone, Phonebook up to 2000 entries. The system should support Voice and Fax Codecs G.711 A-law/U-law, G.722, G.723.1 5.3K/6.3K, G.726, G.729A/B, GSM, AAL2-G.726-32; T.38, Video Codecs H.264, H.263, H263 i/c connection etc. complete as reqd. The quoted model/System should have Type Approval Certificate as per TEC specification number TEC/GR/SW/PBX-005/01/Sept-16 or latest. Tenderer must submit valid TEC approval certificate along with the offer and it should be on the name of manufacturer/tenderer only. The quoted system should be STQC approved. The STQC certificate should be enclosed alongwith the tender The system should also have valid MTCTE certificate from TEC (To be submitted alongwith tender. OEM Authorisation Certifcate for this specific tender is required. Complete in all respects as approved and desired by the Engineer in-charge at site |
| 3 | Supply, installation, testing & Commissioning of IP extensions license for supporting of Core IP or any 3rd party SIP Phone.Complete in all respects as approved and desired by the Engineer in-charge at site |
| 4 | Supply, installation, testing & Commissioning of 48-port Analog Extensions module configurable system featuring 48 female RJ-11 connectors and a network interface with 2 RJ-45 10/100 Mbps Base-T Ethernet ports, along with optional 1000M LAN/WAN support on select models, providing voice support with codecs such as G.711 A/U law, G.723.1, G.729A/B, G.726, iLBC, and AMR, along with features like comfort noise generation (CNG), G.168 echo cancellation, DTMF modes (Signal, RFC2833, Inband), silence suppression with comfort noise, automatic echo cancellation, and call progress analysis (CPA) including positive voice detection, while offering configuration and management through a web UI for instant management and status monitoring, as well as Telnet and SSH access, and supporting FoIP protocols such as T.38 for fax transcoding from T.30 protocol with V.17 modulation schemes, transmission over packet networks, and pass-through up to 14.4 kbps, in addition to application capabilities like call waiting, blind and attended transfer, call forward on busy or no reply, unconditional call forwarding, hotline, call hold, do not disturb (DND), call pickup, 3-way conferencing, and voicemail, further supporting VoIP protocols including TLS/SRTP, OpenVPN, SIP V2.0 (RFC 3261, 3262, 3264), IMS/3GPP, REFER (RFC 3515), ARP/RARP (RFC 826/903), SNTP (RFC 2030), DHCP/PPPOE, TFTP/HTTP/HTTPS, DNS/DNSSRV (RFC 1706/RFC 2782), and VLAN 802.1P/802.1Q, while delivering strong network capabilities such as static IP, PPPOE, DHCP client, IPv4 and IPv6, static and dynamic ARP, DIFFServ and TOS, NAT (route and bridge), MAC address cloning, static routing, built-in firewalls, QoS with traffic shaping, and voice, data, and management VLANs, and finally enabling advanced call routing features including port groups, IP trunks, primary and secondary SIP accounts, 48 inbound and outbound routing options, number manipulation with digit maps, TDM to IP or IP to TDM conversion, and IP load balancing with fault tolerance.Complete in all respects as approved and desired by the Engineer in-charge at site |
| 5 | Supply, installation, testing & Commissioning of 4 Analog Trunks gateway interface features an RJ11 connector, supporting DTMF and pulse dialing modes, with caller ID detection via FSK and DTMF, along with polarity reversal, answer delay, and detection capabilities such as busy tone and no current detection, while the network functionality includes static and dynamic IP configuration, PPPOE, DHCP client, IPv4 and IPv6 support, and compatibility with protocols like TCP, UDP, TFTP, FTP, ARP, RARP, Ping, NTP, SNTP, HTTP/HTTPS, and DNS, as well as diagnostic tools such as Ping and Tracert, and DHCP options 66, 120, and 121, in addition to VoIP protocol support including SIP v2.0 over UDP/TCP (RFC 3261), SDP, RTP (RFC 2833), and multiple RFC standards such as 3262, 3263, 3264, 3265, 3515, 2976, and 3311, along with SIP TLS/SRTP, RTP/RTCP (RFC 2198, 1889), RFC 4028 session timer, RFC 3266 IPv6 in SDP, RFC 2806 TEL URI, RFC 3581 NAT with rport, outbound proxy, DNS SRV/A query/NAPTR query, SIP trunking, early media and early answer, and NAT traversal using STUN and static or dynamic NAT, while voice and fax features include codecs such as G.711 A/U law, G.723.1, G.729A/B, and G.726, along with silence suppression, comfort noise generation (CNG), voice activity detection (VAD), G.168 echo cancellation up to 128 ms, adaptive jitter buffer, programmable gain control, T.38 fax with pass-through, modem/POS support, DTMF modes (Signal, RFC2833, Inband), VLAN 802.1P/802.1Q, and Layer 3 QoS with DiffServ, and maintenance capabilities including SNMP v1/v2/v3, TR-069, auto provisioning via web or Telnet, configuration backup and restore, firmware upgrades via web, CDR, Syslog, network capture, NTP with daylight saving time, IVR-based local maintenance, and cloud-based management, along with software features such as port grouping, web ACL, Telnet ACL, action URL, digit map configuration, routing rules based on prefixes, and caller or called number manipulation. Complete in all respects as approved and desired by the Engineer in-charge at site |
| 6 | Supply, installation, testing & Commissioning of SIP Trunk license for any service provider or to network with any telecom equipement. Complete in all respects as approved and desired by the Engineer in-charge at site |
| 7 | Supply, Installation, testing & Commissioning of Operator Console device should have 4.3-inch (480x272) color screen LCD along with a 3.5-inch (320x480) color screen LCD for DSS keys, equipped with tri-color LED DSS keys, a system display clock, message waiting indication, 10 line keys, 4 navigation keys, 4 soft keys, and 6 function keys including hold, call forward, phonebook, MWI, headset, and redial, along with volume control keys for up, down, and mute (microphone), 42 DSS keys with tri-color LEDs, and 3 page-switch keys, while supporting configuration via web, export and import options, a web management portal, and auto-provisioning through FTP, TFTP, HTTP, HTTPS, DHCP option 66, SIP PNP, and TR-069, as well as phonebook import and export, web- based packet dump, firmware upgrades, and syslog, and delivering Shield HD voice features such as HD handset and speaker, hearing aid compatible (HAC) handset, acoustic shield, wideband codecs including AMR-WB, Opus, and G.722, narrowband codecs such as AMR-NB (optional), Opus, G.711 (A/H), G.723.1, G.729AB, G.726-32K, AMR, and ILBC, with DTMF support via in-band, RFC2833, and SIP INFO, along with full-duplex hands-free speakerphone with AEC, VAD, CNG, AEC, BNE/NR, and PLC, supporting 20 SIP lines, a local phonebook with up to 2000 entries or remote phonebook via XML/LDAP, 6-way conference calling, call logs with up to 1000 entries for incoming, outgoing, and missed calls, manual or automatic date and time setting, voice message waiting indication, programmable DSS and soft keys, network time synchronization, built-in Bluetooth 2.1 with support for Bluetooth headsets, Wi-Fi dongle, and wireless headsets, as well as call recording via flash drive or server, Action URL/Active URI, uaCSTA, and features like busy lamp field (BLF) with idle, ringing, and busy indicators, LED indicators, call history, speed dial, redial, call forward, call waiting, call transfer, call hold, call return, group listening, emergency call, mute, auto answer, voice message on server, do not disturb (DND), hotline, hot desking, anonymous call, auto answering, call parking and pickup, call out, call answer, and call reject, while also supporting RTCP-XR (RFC 3611), VQ-RTCPXR (RFC 6035), Gigabit Ethernet, dual bridged port for PC bypass, IPv4 and IPv6 or dual stack, static, DHCP, and PPPoE network modes, 802.1X authentication, VPN via L2TP or OpenVPN, VLAN, LLDP, Layer 2 QoS (802.1Q, 802.1P) and Layer 3 QoS (TOS, DiffServ), call server redundancy, SIP 2.0 over UDP, TCP, and TLS, RTP, RTCP, and SRTP, TLS, STUN, ICMP, ARP and RARP, DNS, DDNS, DHCP, PPPOE, SNTP, FTP, TFTP, SSH, HTTP, HTTPS, TR-069, PPP, and LDAP protocols. Complete in all respects as approved and desired by the Engineer in-charge at site |
| 8 | Supply, installation, testing & Commissioning of DSS for Opeartor Console DSS keys which delivere high-definition audio, wide band audio support, with advanced noise-cancelin feature for crystal- clearHD voice quality and feature advanced acoustic echo cancellation to minimize background noise.6-wayconference call, Buit in Bluetooth, Full-duplex hands-free speakerphone, Phonebook up to 2000 entries. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 9 | Supply, installation, testing & Commissioning of Gigabit IP Phone the device features a 2.4-inch 132x64 pixel LCD with backlight, along with LED indicators for call and message waiting, and dual- color (red or green) illuminated LEDs for line status information, offering an intuitive and multilingual user interface with icons and soft keys, and caller ID display with name and number, while delivering HD voice capabilities including HD handset and speaker, hearing aid compatible (HAC) handset, acoustic shield, wideband codecs such as AMR-WB (optional), Opus, and G.722, and narrowband codecs including AMR-NB (optional), Opus, G.711 (A/μ), G.723.1, G.729AB, G.726, and iLBC, along with DTMF support via in-band, RFC2833, and SIP INFO, and full-duplex hands-free speakerphone with AEC, VAD, CNG, PLC, adaptive jitter buffer (AJB), and automatic gain control (AGC), supporting 2 VoIP accounts and call features such as call hold, mute, DND, speed dial, hotline, call forward, call waiting, call transfer, group listening, emergency call, redial, call return, auto answer, and local 5-way conferencing, along with direct IP calling without SIP proxy, 10 built-in ringtone selections, manual or automatic date and time settings, dial plan, XML browser, action URL/URI, RTCP-XR, VQ-RTCPXR, multilingual support, and enhanced DSS keys, while also offering advanced telephony features such as busy lamp field (BLF), anonymous call and rejection, hot-desking, voicemail, flexible seating, executive and assistant functions, call park and pickup, centralized call recording with visual voicemail, and supporting SIP v1 (RFC 2543) and v2 (RFC 3261), call server redundancy, NAT traversal via STUN, IP assignment via static or DHCP, HTTP/HTTPS web server, SNTP-based time synchronization, UDP/TCP/DNS-SRV (RFC 3263), QoS with 802.1p/Q VLAN tagging and Layer 3 TOS/DSCP, SRTP for voice security, TLS, HTTPS certificate management, AES encryption for |
| 10 | Supply, Installation, testing & Commissioning of 8 PoE port + 2 Port. The switch should have a total of 10 Gigabit ports including 8 ports of 10/100/1000 Mbps Ethernet PoE and 2 dual personality ports, should have a non- blocking wire-speed switch fabric and be upgradeable to a cloud-managed switch with a simple firmware upgrade without changing hardware, should provide a minimum 20 Gbps backplane, at least 15 Mpps forwarding rate, a, should support a minimum of 16K MAC addresses, should support EEE IEEE 802.3az standard for minimizing power consumption on a per-port basis, should support dual software (firmware) images, should support IEEE standards including 802.3, 802.3u, 802.3ab, 802.3z, 802.3x, 802.3af PoE, and 802.3at PoE+, should support spanning tree protocols including IEEE 802.1D, 802.1w RSTP, and 802.1s MSTP, should support IEEE 802.1p class of service, IEEE 802.1X port authentication, and IEEE 802.3ad LACP aggregation, should support traffic management and QoS features including rule-based and port-based rate limiting with 64 kbps granularity, port-based egress traffic shaping, jumbo frames up to 9KB, broadcast storm control, IEEE 802.1p priority queues, IGMP/IGMP snooping v1/v2/v3, and congestion control on all ports, should support link aggregation with IEEE 802.3ad LACP and up to 5 aggregation groups, should support resilient networking with IEEE 802.1w RSTP, IEEE 802.1s MSTP, and multiple rapid spanning tree protocols, should support user security and authentication features including MAC filtering per port, IEEE 802.1Q VLAN tagging, protocol-based VLAN, IP subnet-based VLAN, guest VLAN, MVR, IEEE 802.1X authentication including MAC-based and guest VLAN, Layer 2 Protocol Tunneling (L2PT), GVRP for automatic VLAN registration, at least 1K static VLAN and up to 4K dynamic VLANS, port-based VLAN and VLAN isolation, limited MAC addresses per port with configurable aging time, loop guard, RADIUS MAC login, and 802.1X port-based authentication with VLAN and bandwidth assignment, should support IEEE 802.1ab LLDP and MED, should support NTP, Syslog, and DNS client, should provide network administration security including SSL, static and dynamic IP-MAC-port binding, DHCP snooping, ARP inspection, and AAA through RADIUS and TACACS+ servers, should support IPv6 features including IPv6 addressing architecture (RFC 4291), dual stack (RFC 4213), ICMPv6 (RFC 4443), path MTU (RFC 1981), minimum MTU size of 1280 (RFC 5095), encapsulation for MTU up to 1500, neighbor discovery (RFC 4861), DHCPv6 relay, default DHCP client mode, and duplicate address detection, should support network management features including web- based management, SNMP v1/v2c/v3, RMON groups 1, 2, 3, and 9 for monitoring and analysis, port mirroring for source/destination/both, centralized management software for configuration and maintenance of multiple Layer 2 switches, support for sFlow for traffic analysis. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 11 | Supply, installation, testing & Commissioning of Analog Push Button telephone Handset with Display & CLI. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 12 | Supply, installation, testing & Commissioning of of MDF 100 pair with Krone complete in all respects as approved and desired by the Engineer in-charge at site. |
| 13 | Supply, installation, testing & Commissioning of of MDF 20 pair with Krone complete in all respects as approved and desired by the Engineer in-charge at site. |
| 14 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: |
| 15 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 16 | CAT 6 LAN cable |
| 17 | Supply and erection of telephone cable with solid bare copper conductor, special grade PE insulation, paired, polyster taped, nylon rip cord, FR PVC sheathed, conforming to TEC Specification No. G/WIR-06/03 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 18 | Telephone Cable 0.5 Sq.mm, 2 Pair |
| 19 | Telephone Cable 0.5 Sq.mm, 20 Pair |
| 20 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 21 | Wiring Telephone socket point RJ11 (one module) |
| 22 | Wiring network socket point RJ45(one module) |
| 23 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 24 | Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) |
| 25 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 26 | Providing Online 20 KVA UPS System |
| 27 | Supply, Installation, Testing and Commissioning of 20KVA ±192VDC online UPS having following features:> (3:3) High Frequency>50Hz/60Hz Frequency converter mode>ECO mode operation for energy saving(ECO)>3-Stage Extendable Charging Design for Optimized Battery Performance.>Unity Output Power Factor> 12 Amp Inbuilt Charger>32 Battery UPS>Built-in maintenance bypass & static bypass switches.>Parallel operation up to 3 units(optional)>1 Year Warranty>Parallel Redundancy up to 3 Units with Single Battery Bank>One-year on site warranty on UPS, minimum 30 minutes backupComplete in all respect as desired by the engineer in charge at site. |
| 28 | Supply and Erection 12V/42Ah Sealed maintenance free battery, Complete in all respect as desired by the engineer in charge at site. |
| 29 | Supply and erection of Battery Rack with batteries connecting cables( For min. 32 Batteries). Complete in all respect as desired by the engineer in charge at site. |
| 30 | Providing Networking System along with allied accessories: |
| 31 | SITC of Distribution Switch with minimum usable 24 10/100/1000BASE-T ports, 2 10GBASE-T ports , 4 10G SFP+ ports L3 Stackable Managed Switch with Redundant Power Supply Support.1 x RJ45 console port, RJ-45 port for out-of band-management port for accessing the CLI of the switch and USB port. 168 Gbps Switching capacity or higher or non-blocking architecture. 64 Bytes packet forwarding rate should be 125 Mpps or higher. Switch MAC table should be at least 16K or higher. Physical Stacking up to 9 units per stack. Stacking bandwidth up to 80G and up to 32 devices per virtual stack. Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol and ERPS as per standard ITU-T G.8032. BPDU Filter, BPDU restriction, Root restrction. Loopback detection (LBD). IGMP Snooping v1/V2/V3 & IGMP groups 1K or more IGMP groups and require support for IGMP Snooping Fast Leave. MLD Snooping v1/v2 & MLD group 1K or more and require support for MLD Snooping Querier. 16 L3 IP interfaces and IPv4/IPv6 Loopback interface. IPv6 Neighbor Discovery (ND). VRRPv3, Equal-Cost Multi-Path (ECMP) and UDP helper. Static route for both IPv4 and IPv6, OSPFv1, v2 & v3, RIP V1/V2/ng. Should have Policy-based Route (PBR). IEEE 802.1Q VLAN with different type of VLAN like Port based, Voice VLAN, Private, Double (Q-In-Q), Multicast VLAN (ISM VLAN for IPv4/IPv6), 802.1v Protocol VLAN ,VLAN Trunking. should have per-port broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance. port security to secures the access port based on MAC address. Require prevention of DoS attacks, which include Land, Blat, TCP Null Scan, TCP Xmas Scan, TCP SYNFIN, Ping of Death Attack and TCP Tiny Fragment attack. DHCP snooping and DHCP server screening, DHCP server. 802.1X port based and 802.1X host based access control, Identity-driven Policy (VLAN, ACL or QoS) Assignment. RADIUS and TACACS+ authentication. Authentication database failover. QoS (quality of service) IEEE 802.1P for traffic prioritization. 8 queues per port. Different type of QoS priority like Strict Priority Queue and Weighted Round Robin, Strict + WRR, Congestion control using Weighted Random Early Detection (WRED) or WTD. Remark 802.1p priority, Remark ToS/DSCP and Rate limiting in Policy map. Support at least 2K ingress & 512 egress access control entries. ACL based on MAC, IPv4 and IPv6, TCP/UDP port number, User-defined packet contentm, CPU Interface Filtering. Able to manage trough Web-GUI, Fully functional CLI interface and Telnet. Should have multiple Image and configuration support to reduced down time for the switches. sFlow for monitoring traffic in data networks, SNMP v1, v2c, v3 and SNMP Traps and RMON. Support for DHCP Client support for IPv4/IPv6, DHCP server, DHCP Relay and DNS client. Should have SNTP/NTP protocol for time synchronization. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED.. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED. Operating temperature should be 0 to 50 ˚C. Switch should be EMI Certificates FCC, CE and Safety Certifications cUL/UL, CB. All Switches, Wireless and its Networkiing Components from Same OEM. OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards. OEM should have Indian based operation at least for a period of 20+ years and should have an Annual Turnover of Rs. 500 Crores and above in any of last three consecutive Audited Financial years. (To ensure only principal networking companies participate having strong Product , Support and Service.)complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 32 | Supply, Installation, Testing and Commissioning of Patch Panel should be made of cold rolled steel.Should conform to TIA / EIA 568-C.2 Component Compliant.Should terminate 24 UTP CAT 6 (4 pair) Cables.Should confirm to EIA/TIA 568A wiring Pattern.Each port Should be features the spring-loaded shutter.Should be prevents incomplete mating Should be protects from dust and contaminants.Should be Front and rear port labelling as well as panel identification label.Should be Integral cable management shelf ensures bend radius compliance.Operating Life should be minimum 750 insertion cycles.Should be RoHS compliant. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 33 | Supply, Installation, Testing and Commissioning of Patch Cord 1 Mtr Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 34 | Supply, Installation, Testing and Commissioning of Patch Cord 2 Mtr. Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 35 | Supply, Installation, Testing and Commissioning of 27U Network Enclosure Frame-600X800-STEEL with accessories like fan, pdu, cable manager etc. Supply of 27U Enclosure Frame-800X1000-STEEL, Caster Wheels Set of 4 (2 with Brakes & 2 without Brakes),Adjustable Levellers set of 4, Glass Door-800-27U, Metal Door-800-27U-Vented, Side Panels-1000-27U-Vented, Mounting Hardware-(Pack of 20), FHU with 4 FAN 360CFM, Vertical Power Distribution Unit with 12 x 5/15 sockets Round Pin, 230 Volts AC, 32 Amp with Plug, Vertical Cable Manager-27U-Loop, Horz. Cable Manager-1U-Loop, Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility maximizing the usable mounting space, Depth adjustable mounting slots, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with pretreatment process meeting all industry standards, Grounding and Bonding Options can be provided, 100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment, Conforms to DIN 41494 or equivalent standard, Welded Frame, Lockable Toughened Glass Door, Metal Vented Door Steel, DIN Standard 10mm Sq. Slots / Direct M6 Tap, 19” Mounting angles made of formed steel Powder Coated, Welded to Frame, Vented and Field Cable entry exit cut outs complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 36 | Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site.complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 37 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 38 | Wiring Networking socket point RJ45 (one module) |
| 39 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 40 | CAT 6 LAN cable |
| 41 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 42 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 43 | Providing Audio Video and Conference System: |
| 44 | Supply, installation, testing & Commissioning of delegate conference gooseneck microphone shall be a table-embedded condenser microphone with a minimum length of 230mm, designed for professional conferencing and speech applications. It shall support multiple selectable polar patterns including cardioid, omnidirectional, super-cardioid, bi-directional (figure-of- eight), and uni- directional for flexible usage. The microphone shall have a frequency response of 90Hz to 20kHz (- 3dB), sensitivity of -32dBV @1Pa or better, and a signal-to-noise ratio of 90dB or higher. It shall be capable of handling a maximum SPL of 120dB (1% THD at 1kHz) with total harmonic distortion less than 0.1%. The unit shall have a nominal impedance of 120 ohms and shall operate on 24V-48V phantom power. The microphone shall feature a balanced 3-pin XLR interface and shall be constructed with an all-metal body with anti-RF interference design and integrated vibration isolation to minimize handling noise. It shall include a built-in windshield and shall be suitable for flush/table mounting in boardrooms, conference rooms, and similar environments.Complete in all respects as approved and desired by the Engineer in-charge at site |
| 45 | Supply, installation, testing & Commissioning of chairman conference gooseneck microphone shall be a table-embedded condenser microphone with a minimum length of 230mm, designed for professional conferencing and speech applications. It shall support multiple selectable polar patterns including cardioid, omnidirectional, super-cardioid, bi-directional (figure-of-eight), and uni-directional for flexible usage. The microphone shall have a frequency response of 90Hz to 20kHz (-3dB), sensitivity of -32dBV @1Pa or better, and a signal-to-noise ratio of 90dB or higher. It shall be capable of handling a maximum SPL of 120dB (1% THD at 1kHz) with total harmonic distortion less than 0.1%. The unit shall have a nominal impedance of 120 ohms and shall operate on 24V-48V phantom power. The microphone shall feature a balanced 3-pin XLR interface and shall be constructed with an all-metal body with anti-RF interference design and integrated vibration isolation to minimize handling noise. It shall include a built-in windshield and shall be suitable for flush/table mounting in boardrooms, conference rooms, and similar environments.Complete in all respects as approved and desired by the Engineer in-charge at site |
| 46 | Supply, installation, testing & Commissioning of conference system controller shall be a fully digital audio controller with built-in high-performance processor, designed for professional conferencing applications. It shall support minimum 40 delegate units expandable up to 128 units with external power supply, using RJ-45 based connectivity with Power over Ethernet (PoE) for combined audio and power transmission. The unit shall support AOIP (Audio over IP) with low latency and 48kHz sampling rate, along with TCP/IP based control architecture for integration with PC software and third-party systems. It shall provide minimum 4 RJ-45 ports for microphone units and additional RJ-45ports for camera tracking control, software control, and wall-mounted controller interface. The controller shall support multiple speech modes including FIFO, normal, free, and apply mode, with selectable number of open microphones. It shall have a frequency response of 20Hz to 20kHz, signal-to-noise ratio greater than 85dB, and dynamic range of 80dB or better. The system shall support centralized control functions such as microphone gain adjustment, priority management, forced on/off, and status monitoring. It shall feature ring network architecture for fail-safe operation, hot plug-and-play functionality, and integration with camera tracking systems. The unit shall be rack-mountable (1U) and operate on PoE+ and 100-240V AC power supply, suitable for boardrooms, conference halls, and unified communication environments.Complete in all respects as approved and desired by the Engineer in-charge at site |
| 47 | Supply, installation, testing & Commissioning of junction box shall be a microphone control and distribution unit designed for use with a digital conferencing system, capable of interfacing between the audio controller and microphone units. It shall support connection of minimum 2 microphone units per junction box and shall include 2 RJ-45 ports for microphone connectivity and 2 RJ-45 ports for link/cascade between junction boxes. The unit shall support DC 24V power distribution to connected microphones and shall have a frequency response of 40Hz to 20kHz with total harmonic distortion less than 0.1%. It shall include selector switches to configure connected microphones as host or participant units, along with LED indication for status monitoring. The unit shall be supplied with minimum 4 RJ-45 patch cords for interconnection and shall support scalable architecture for multiple unit expansion. The junction box shall have low power consumption of approximately 2W and shall be designed for reliable operation in temperatures ranging from -10°C to 60°C with humidity tolerance of 10% to 85%. The enclosure shall be compact, robust, and suitable for installation in conference tables and meeting room environments. Complete in all respects as approved and desired by the Engineer in-charge at site |
| 48 | Supply, installation, testing & Commissioning of professional wireless audio system designed for reliable and high-quality sound transmission in live events, conferences, and stage applications. It delivers stable RF performance with clear audio output, ensuring minimal interference and onsistent signal strength. The system typically includes a receiver unit with multiple channel selection, easy synchronization, and user-friendly controls, along with handheld or bodypack transmitters. Built for durability and ease of operation, the SOW 6150 is suitable for presentations, performances, and public address setups where mobility and dependable wireless audio are essential. Complete in all respects as approved and desired by the Engineer in-charge at site |
| 49 | Supply, installation, testing & Commissioning of professional dual-channel power amplifier designed to deliver reliable and efficient audio performance for live sound and installation setups. It provides stable power output with low distortion, ensuring clear and consistent sound reproduction across a wide frequency range. The amplifier features advanced protection systems such as overload, short- circuit, and thermal protection for safe operation. With standard input/output connectivity and user- friendly front panel controls, the SMA 250D is suitable for driving speakers in venues like uditoriums, conference halls, and public address systems. Complete in all respects as approved and desired by the Engineer in-charge at site |
| 50 | Supply, installation, testing & Commissioning of wireless microphone system designed for clear and stable vocal transmission in live sound, presentations, and public address applications. It includes a handheld dynamic microphone paired with a dedicated receiver unit for reliable wireless connectivity. The system delivers strong signal stability with minimal interference, ensuring clean and intelligible audio output. It is easy to operate, supports plug-and-play setup, and is suitable for conferences, events, classrooms, and stage performances where mobility and speech clarity are required complete in all respects as approved and desired by the Engineer in-charge at site |
| 51 | Supply, installation, testing & Commissioning of wireless lavalier microphone system designed for hands-free voice capture in presentations, conferences, lectures, and public speaking applications. It includes a compact lapel (clip-on) microphone and a dedicated receiver unit for stable wireless transmission. The system delivers clear and natural vocal reproduction with minimal background noise, ensuring good speech intelligibility. It offers easy setup and reliable performance, making it suitable for professional and educational environments where discrete and mobile audio capture is required .complete in all respects as approved and desired by the Engineer in-charge at site. |
| 52 | Supply, installation, testing & Commissioning of The suitable wall mount bracket shall be fabricated heavy-duty steel structure designed to securely support IFPD displays, with anti-rust powder coating and suitable load-bearing capacity as per display size and weight. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 53 | Supply, installation, testing & Commissioning of professional Full HD PTZ (Pan-Tilt-Zoom) camera designed for video conferencing, lecture capture, broadcasting, and training environments. It features a 1/2.8\\" HD CMOS sensor with 20X optical zoom and up to 12X digital zoom, delivering clear and detailed image capture even from long distances. The camera supports Full HD 1080p output with smooth 60fps performance and offers multiple video interfaces including HDMI, USB 3.0, and IP streaming for flexible integration. It provides wide-angle coverage with precise pan and tilt control low-noise image processing, and strong compatibility with control protocols like VISCA and PELCO. Compact and reliable, t suitable for medium to large rooms such as conference halls, classrooms, auditoriums, and houses of worship complete in all respects as approved and desired by the Engineer in-charge at site. |
| 54 | Supply, installation, testing & Commissioning of 8-input and 8-output digital audio matrix processor used for flexible audio routing and control in professional sound systems. It provides DSP functions such as mixing, equalization, gain, delay, and noise control, and is commonly used in conference rooms, auditoriums, and multi-zone installations for centralized audio management complete in all respects as approved and desired by the Engineer in-charge at site. |
| 55 | Supply, installation, testing & Commissioning of Screen Size (W) 2560 x (H) 1440 mm, Pixel Pitch 1.53mm indoor / GOB,Resolution (w x h) 208 x 04, Pixel Density: 422,626 pixel/m2,Pixel configuration: R1G1B,Cabinet Dimensions (w x h) 640 x 480 mm, Physical Resolution (w x h) 416x312 ,Cabinet Material: Diecast Aluminum Weight/Cabinet:7Kg, Thickness:60 mm, ervice:Front, Power Supply unit: 5V-40A, Brightness: 800 cd/m2(max), Viewing Angle :140°/140°, Minimum Viewing Distance: >1.53m, Brightness Control: 256 levels,Contrast Ratio=5000:1,Grey scale :16bits, Refresh frequency: >3840/7680Hz, Driving mode:Constant Current Driving,Scan method: 1/52 Scan,Input Voltage: AC 110-240V/5V60Hz, Power Consumption (m2): <450W/m Max <220W/m2 Avg, Lifetime: 1,00,000 hours, International Protection: IP45,Operation emperature: -0°C~50°C / 10%-65%RH (No Condesation), Working humidity: 10%-60% RH (No Condesation) complete in all respects as approved and desired by the Engineer in-charge at site. |
| 56 | Supply, installation, testing & Commissioning of server display size 8.40 X 4.72 ft, Inputs: 1x HDMI 2.0 (IN & LOOP) 2x HDMI 1.3,1x 10G optical fiber port (OPT 1) 1x 3G-SDI (IN & LOOP) 1x USB 3.0 (Play images or videos saved in a USB drive.),Output Connectors:-4x Gigabit Ethernet ports A single device supports up to 2.6 million pixels, delivering a maximum width of 10,240 pixels and a maximum height of 8192 pixels. 2x Fiber outputs OPT 1 sends the output on Ethernet ports 1~4. OPT 2 copies or backs up the output on Ethernet ports 1~4. 1x HDMI 1.3 For monitoring display. 1x 3D connector Directly connect a third-party 3D emitter. Audio input and output :Audio input accompanied with HDMI sources 3.5 mm independent audio input and output Adjustable output volume,EDID management Import and export EDID files.,Easy preset saving and loading Up to 256 user-defined presets supported Load a preset by simply pressing one button. Save, overwrite and delete a preset. Preview the layer layout saved in the preset.,Multiple layer display Supports 6*2Kx1K layer resources. Users can create layers in three different pecifications - 4Kx2K, 4K×1K, and 2K×1K. These layers will use 4x, 2x, and 1x 2K layer resources respectively, depending on the capacity of the input source connector used to open the layers. Adjustable layer size and position Adjustable layer priority Adjustable aspect ratio,Color adjustment Supports output color management, including brightness, saturation, contrast and hue.,Supports USB playback for instant plug-and-play onvenience., Electrical Parameters: Electrical Parameters Power connector Rated power consumption Operating Environment Temperature 100-240V, 50/60Hz 41 W 0°C to 50°C, Humidity Storage Environment Temperature, 5% RH to 85% RH, non-condensing -10°C to +60°C Humidity, Physical Specifications Dimensions: 5% RH to 95% RH, non-condensing, Net weight 482.6 mm x 302.2 mm x 50.1 mm, 3.8 kg. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 57 | Supply, installation, testing & Commissioning of wall mount bracket shall be fabricated heavy-duty steel structure designed to securely support IFPD displays, with anti-rust powder coating and suitable load-bearing capacity as per display size and weight. complete in all respects as approved and desired by the Engineer in-charge at site |
| 58 | Supply, installation, testing & Commissioning of compact presentation remote device used to control slides wirelessly during meetings, lectures, and presentations. It typically includes functions such as slide navigation (next/previous), laser pointer, and screen control, allowing presenters to move freely without being near the computer. It offers plug-and-play USB connectivity with stable wireless transmission, making it suitable for classrooms, conference rooms, and professional presentations where smooth and hands-free control is required complete in all respects as approved and desired by the Engineer in-charge at site |
| 59 | Supply, installation, testing & Commissioning of wireless audio/video transmission system designed to send signals over distances up to 70 meters with stable and low-latency performance. It is commonly used for extending HDMI or AV signals in conference rooms, classrooms, and presentation setups. The system supports plug-and-play operation with reliable signal quality, ensuring clear transmission without significant loss or interference, making it suitable for medium-range wireless connectivity between source devices and displays complete in all respects as approved and desired by the Engineer in-charge at site |
| 60 | Supply, installation, testing & Commissioning of high-definition multimedia cable used to transmit audio and video signals between devices such as laptops, projectors, displays, and AV equipment. It supports digital signal transfer for clear, high-quality output with minimal loss. The 2-meter length makes it suitable for short-distance connections in conference rooms, classrooms, and home or professional AV setups complete in all respects as approved and desired by the Engineer in-charge at site. |
| 61 | Supply, installation, testing & Commissioning of long-distance (min 10 mtr) high-definition multimedia cable used to transmit digital audio and video signals between devices such as laptops, media players, projectors, and displays. It ensures stable signal transfer with high-quality resolution support, making it suitable for professional AV installations, conference rooms, classrooms, and auditoriums where devices are placed farther apart complete in all respects as approved and desired by the Engineer in-charge at site. |
| 62 | Supply, installation, testing & Commissioning of 4x2 HDMI 2.0 matrix switcher designed for professional AV applications, allowing flexible routing of four HDMI input sources to two HDMI displays. It supports up to 4K resolution at 60Hz with HDR and HDCP 2.2 compatibility, ensuring high- quality video transmission. The device enables seamless switching and distribution of audio-video signals and includes multiple control options such as front panel buttons, IR remote, RS-232, and Ethernet/web interface, making it suitable for conference rooms, classrooms, control rooms, and digital signage systems complete in all respects as approved and desired by the Engineer in-charge |
| 63 | Supply, installation, testing & Commissioning of Category 6A (Cat6A) shielded twisted pair (STP) communication cable designed for high-speed data and AV network installations. It features 4-pair 23 AWG solid copper conductors with overall foil shielding and a drain wire to ensure strong protection against electromagnetic interference and signal loss. The cable supports high-performance pplications such as 10G Ethernet, HDBaseT, audio-video distribution, IP control systems, PoE, and structured LAN networks, making it suitable for professional AV, conferencing, and data center environments. It comes in a black flame-retardant jacket and is typically supplied in 1000 ft reels for large installations. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 64 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 65 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 66 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 67 | Overall size 1.5sq.mm (48/0.20mm), 2Core |
| 68 | Providing CCTV System: |
| 69 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Rugged Bullet /DomeCamera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944), Max Frame Rate: 50fps or better, Quad stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux @ F1.6 (color), 0 Lux IR On, Smart IR with upto 50m IR distance or better, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3-1/100,000s; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG Streams: 4, Video Streams configurable at different Resolutions and FPS Max@50FPS, 3.6 mm, Fixed, F1.4,Electronic Image Stabilization with G- Sensor, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence, Protocols: IPv4, IPv6, TCP/IP, HTTP, HTTPS, RTSP/RTP/RTCP, IGMP/Multicast, SMTP, SNMP. DHCP, NTP, DNS, DDNS, COS, QoS, 802.1X, UPnP, mDNS (Bonjour), UDP, ICMP, ARP, TLS, SFTP Video Analytics Server featuer. Motion Detection, Scene Change, Tamper Detection, Smart Motion, Intrusion, Loitering, Line Crossing Detection, Unattended Object Detection, Missing Object Detection, People Counter, Queuing, Crowd Gathering, Heat Map, Face Detection, camera reset option in camera, 5 Privacy Mask, 6 Region Of Intreset, Defog, TLS 1.2 & 1.3, AES-128/256, SSH/Telnet closed, Stream Encryption, Secure boot, Prevent brute-force attack, 2TB Micro SD/SDHC/SDXC card slot; Gore Vent, POE (802.3 af) and 12V DC, Max 10.6 W or better, IP 66 & IP67, IK 10 vandal proof with Aluminium + Polycarbonate Housing. Having Operating temp range:-30°C-60°C. Certifications: ONVIF Profile S,G,T,M compliant (Can be verified from onvif Website, T profile must have secure streaming), UL, FCC, CE, RoHS, BIS-ER, STQC Complied & NDAA Section 889 compliant.Camera should be with five year warranty. The MAF and warranty should be submitted by OEM directly. complete in all respect as desired by engineer in-charge. |
| 70 | Supply, erection, testing & commissioning of 64 Channel NVR (Network Video Recorder shall be support the STOC Cameras) Main Processor ARM Processor Operating System Embedded LINUX Onvif Compliance ONVIF Profile S User Management User level: Administrator, Regular user Log System, Recording, User Date & Time Time Zone, Manual, Automatic Sync NTP, Daylight Saving Time Fan Yes Security Encrypted streaming and control, Inputs 64 channels, Audio Input Output 3.5 mm Line in x1 3.5 mm Line out x1 Two-way Communication Supported Audio Format G.711, Interface HDMI 1 (4K Max), HDMI 2 (1080P), VGA x1 (1080P), Resolution: 3840 x 2160, 1920 x 1080, 1280 x 1024, 1024 x 768, Display Split: 1/4/9/16/32/64, OSD Time OSD, channel OSD, Stream Application 1 X 1: 1 ch 12 MP MAX 2 x 2: 4 ch 4 K 4 x 4: 16 ch 2 MP 8 x 8: 64 ch D1, PTZ Operation Direction control, Home, Iris, Preset, Patrol(group), Focus +/- Zoom+/ Compression H.265/H.264 Resolution Up to 3840 x 2160 Frame Rate 30 fps Recording Mode Continuous, Manual, Event Pre-Event Recording Interval Main stream: 2M Sub stream: 1M Post-Event Recording Interval 30 s (Max. 60 s) Recording Stream Camera Stream 1 Camera Stream 2, Recording Throughput 320M, Event Camera: Camera Alarm In, Motion detection, Camera disconnection, Tampering detection System: System Alarm in/out, Disk failure, Disk full, VA (SMD/intrusion/crowd/Multi loitering detection) Event Action Video recording Send email, Buzzer, FTP, Camera Alarm Out, PTZ-Preset, System Alarm Out,Send video to full screen, Alarm Input 16, Alarm Out 6, RS485 Supported RS232 Supported e-SATA Supported, INTERNAL HDD Internal x8 (3.5\\"), HDD Max. Capacity 10TB Manual Backup USB Dongle (FAT Format) Raid Raid 11516, Sync Playback 16 channels, Decoding H.265/H.264: 4000 x 3000 @ 30 fps (1-CH) 3840 x 2160 @ 120 fps (4-CH) 720 x 576 @ 480 fps (16-CH) Search Mode Time search, Event Search, video clip Playback Function Regular (play, pause, stop), play backwards, next frame, Go back 30 seconds, Go forward 30 seconds, speed control, timeline, timeline scale, Digital zoom, snapshot back up Snapshot JPG, Ethernet 10/100/1000Mbps Ethernet (RJ-45) x 2 PoE N351604xxR: 802.3at/af compliant PoE ports x 16 Supported Protocols IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP/RTP/RTCP, SMTP, FTP, DHCP, NTP (Secure), DNS, DDNS, IP Filter, P2P, SNMP Maximum Number Of Users 16, Network Throughput 400M, Smart Phone Compatibility IOS 11 or later and Android 5.0 or later support Browers Edge, Chrome, Firefox, safari, USB Ports Front x 2, usb2.0; Back x1, usb3.0, Power Supply: 100-240V AC, 50/60HZ,DUAL SMPS, Operating Temperature-10°C -55°C (14°F-131°F) Relative Humidity Less than 90% RH Storage Temperature -40°C to 60°C (-40°F 140°F). Emissions FCC Part 15, CE (EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-6-4), ICES-003, Comply with UKCA and RCM Immunity CE (EN 50130-4, EN 55035) Comply with UKCA and RCM Safety UL LISTED TO UL/CSA 62368- 1, CE(EN 62368-1), Comply with UKCA and RCM RoHS CE(EN 63000), UAE (Cabinet Decree No.10 of 2017). Complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 71 | Supply, erection, testing & commissioning of Switches: 24 Ports 10/100/1000 Mbps PoE + 4 Ports 10G SFP+ Smart Managed Layer 2 Switch, Power budget 370W from day1, Support 802.3af/at), Switching Capacity 128 Gbps, MAC Address Table 16K, Packet Forwarding Rate, 95.24 Mpps, Flash Memory 64 MB, DRAM Size 256 MB DDR3, IGMP v1/v2/v3 Snooping & MLD snooping v1/v2, 802.3x Flow Control, HOL Blocking Prevention, LLDP/ LLDP-MED, 802.1D, 802.1W, 802.1s, 802.1Q, 802.1p QOS, SPQ, WRR, WDRR, Bandwidth Control, Static routing, IPv6 Neighbor Discovery (ND), ACL Max. 768 rules shared by IPv4, MAC, & IPv6, Traffic segmentation, ARP Spoofing Prevention, ARP Inspection, DHCP Snooping, MAC authentication, SSH v2, TLS v.1.2, DoS attack prevention, 802.1X Port-based Access Control, Port Security, RADIUS/TACACS+, MD5 authentication, GUI, Full CLI, Telnet Server, TFTP Client, MDI/MDIX, SNMP v1/v2c/v3. Internal/External 6 kV surge protection on all RJ-45 access ports, Operating Temperature -5 to 50°C, Storage Temperature -20 to 70°C, Operating Humidity 0% to 95% relative humidity, Certifiate: EMC EN 55032, Class A; EN 61000-3-2; EN 61000-3-3; EN 55024, Safety EN 62368-1, ROHS EN IEC 63000, 47 CFR FCC part 15: 2017, Subpart V, Class A, ICES-003, IEC 62368-1, IEC 60950-1, IEC 60950-1/AMD1, IEC 60950-1/AMD2, UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14. MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017, OEM Should be ISO 45001, ISO 27001 & ISO 14001 Certified, OEM Should have Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent). Complete in all respects as approved and desired by the Engineer in-charge at site. |
| 72 | Supply, Installation, Testing and Commissioning of Patch Panel should be made of cold rolled steel.Should conform to TIA / EIA 568-C.2 Component Compliant.Should terminate 24 UTP CAT 6 (4 pair) Cables.Should confirm to EIA/TIA 568A wiring Pattern.Each port Should be features the spring-loaded shutter.Should be prevents incomplete mating Should be protects from dust and contaminants.Should be Front and rear port labelling as well as panel identification label.Should be Integral cable management shelf ensures bend radius compliance.Operating Life should be minimum 750 insertion cycles.Should be RoHS compliant. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 73 | Supply, Installation, Testing and Commissioning of Patch Cord 1 Mtr Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 74 | Supply, erection, testing & commissioning of 6000GB Audio Video HDD 3.5 Inches Connector SATA, Interface SATA, Operating Temperature 0°C to 65°C, Transfer Rate minimum 160MB/s, Recording Technology — CMR, Certifications BSMI, ICES-003/NMB-003, CE, FCC KC, Maghreb, RCM, UKCA, VCCI, CB- Scheme, TUV, UL for NVR recording and playback complete in all respects as approved and desired by the Engineer in-charge at site. |
| 75 | Supply erection, testing & commissioning of Smart 55\\" LED Commercial Panel /Regular with 2 HDMI Port, TV Input, 3 Years Warranty, 2 HDMI Port, TV Input, 3 Years Warranty, Resolution 4K, Brightness 300 cd/m2 Support 4K Ultra HD 20 Watt 2.0 Audio Output Web Browser Soft AP, WiFi (bandwidth) Screen Share (Miracast) USB Cloning, 2 No. Of HDMI Port, 2 no USB Port, complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 76 | Supply, Installation, Testing & Commissioning of 6 Mtr HDMI Cable for NVR, UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 77 | Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 78 | Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19\\" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respects as approved and desired by the Engineer in-charge at site. |
| 79 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: |
| 80 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 81 | CAT 6 LAN cable |
| 82 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 83 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 84 | Providing Fire Detection/ Emergency Evacuation & PA System: |
| 85 | FIRE PANELS & ANNUNCIATORS: |
| 86 | Supply, installation, testing & Commissioning of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event , 1000 alarm log history events, Qwerty/ Touch Screen keypad for operation. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 250 analog addressable devices (Devices and detectors). The panel shall work in degrade mode in case of CPU failure, Products not having this feature will offer Redundant CPU. Four access levels, flash EPROM, Panel Shall include 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall support with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 5 Telephones in conference in multiple FFT Risers. The panel shall be expandable upto Min. 10 loop, UL & FM approved. Panel shall have provsion for Modbus/ Bacnet over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable for remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th complete in all respects as approved and desired by the Engineer in-charge at site. |
| 87 | Supply, installation, testing & Commissioning of chassis (Small size) for Amplifier and Digital Series Distribution Board. Chassis should be fabricated from 14-gauge steel, e key-locked door is provided with a pin-type hinge, two keys and the necessary hardware to mount the door, Right- or left-hand hinges, selectable in the field. Door opens 180°, door should be heat dissipation refers to the process of transferring heat away from a system, component, or device to maintain its temperature within acceptable limits. Chassis should be of same make OEM as complete in all respects as approved and desired by the Engineer in-charge at site. |
| 88 | Supply, installation, testing & Commissioning of Loop Cards Class A Wiring with min. supporting cable length Up to 1.2 Km UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 89 | Supply, installation, testing & Commissioning of Digital Voice Command Controlling Board combines the capabilities of a powerful digital audio processor, an eventdriven audio message generator, and a router.The DVC has two wire digital audio ports to connect to wire DAL segments. The DVC may be networked Programmable from NUP port. Up to 32 minutes of standard quality or 4 minutes of high quality digital audio storage of user-selected/created messages and tones. Suppons twisted-pair wire media. Suppons single- and multi-mode fiber-optic media when used with fiber option modules. 4-channel analog audio supported.The DVC Should be Compatible with Auxiliary input for line level, 1.0 VRMS, or 1.41 Vp-p low level audio. Selectable AGC, user control of audio level, and audio supervision are supported. UL Listed: S635.ULC Listed: S635.FM Approved. The solution should be from single OEM complete in all respects as approved and desired by the Engineer in-charge at site. |
| 90 | Supply, installation, testing & Commissioning of Digital Voice Command Keyboard/ Touch Screen for local annunciation and controls; status LEDs and 24 user-programmable buttons.Display All Call, Page Active Evac Areas, Page Active Alert Areas, Page Inactive Areas UL Listed . The solution should be from single OEM complete in all respects as approved and desired by the Engineer in-charge at site. |
| 91 | Supply, installation, testing & Commissioning of Paging Microphone compatible with Emergency evacuation Control Panel UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 92 | Supply, installation, testing & Commissioning of Addressable Smoke photo-Thermal Detector and base with sensitivity range as per NFPA 72. The intelligent detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches. Designed to meet UL & FM Approved . The solution should be from single OEM. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 93 | Supply, installation, testing & Commissioning of Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min.NFPA 72. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches.UL & FM Approved The solution should be from single OEM complete in all respects as approved and desired by the Engineer in-charge at site. |
| 94 | Supply, installation, testing & Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device complete in all respects as approved and desired by the Engineer in-charge at site.UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 95 | Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and Min.110 cd flashintg at 1 Hz for visual indication. UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 96 | Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary / Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in- charge at site. |
| 97 | Supply, installation, testing & Commissioning of Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary/ Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 98 | Supply, installation, testing & Commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device.UL & FM Approved Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM.complete in all respects as approved and desired by the Engineer in-charge at site. |
| 99 | Supply, installation, testing & Commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 100 | Supply, installation, testing & Commissioning of Addressable Fire Fighter's Telephone Jack for two way communication between Remote Fire Fighter & Fire Command Center UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 101 | Supply, installation, testing & Commissioning of Chassis assembly enclousre for Fire fighter telehphone handset, UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 102 | Supply,installation,testing & Commissioning of Digital Audio Amplifier with transformer as per site requierment . Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of Min 95 W ( It may be 1 unit or Combination of Multiple units to achieve the Requirement) at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall be (Wall/Panel Mounted). Integrated 8 channel Digital Voice Evacuation System Controller (as per requierment) capable of broadcasting Evacuation Messages on the same peer-to-peer Network and 2 ways Communication capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC/Amplifier operation. Products not having this feature must provide dedicated CPU for DVC. The Evacuation System Controller shall have FFT Risers to control and conference minimum 30 Telephones.. Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers can be back up of minimum 5 hours using secondary power source(battery power/UPS power) complete in all respects as approved and desired by the Engineer in-charge at site. |
| 103 | Supply, installation, testing & Commissioning of 2W Multi-Tap (0.25W; 0.SW; 1W; 2\/\/}, Ceiling/Wall Mount Speakers. The speakers shall be of the same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 104 | Supply, installation, testing & Commissioning of Back Box for 2W Multi-Tap (0.25W; 0.SW; 1W; 2W}, Ceiling/Wall Mount Speakers as complete in all respects as approved and desired by the Engineer in-charge at site. |
| 105 | Supply, Installation, Testing and Commissioning of LED Glow Type EXIT Sign Board with minimum three hour backup, photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class-1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. |
| 106 | Supply, Installation, Testing and Commissioning of industrial grade Emergency Exit Light with LED Sign 2 Language, inbuilt Battery: 12V, 7AH with min 4 hr Backup made of power coated Sheet Metal, work with AC 220V, 50Hz (+/-15%) and Battery Light Source: 9W x 2 nos LED Bulbs, Battery operating volts: 11V to 14V, Battery charger: Regulated constant volt constant current Battery charging Time: 7 to 8 Hrs (app) Power consumption: 10W (app) while charging, LED display diffuser: Red/Green acrylic transparent, Tillable, Auto lights up while power failure complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. |
| 107 | Supply, installation, testing & Commissioning of Online UPS 1 kva 800 Watts Tower UPS with 1 hour battery backup. Operating Temperature Range 0 to 40 Degree @ 100% Load @ 50 Degree with 50% Load,Storage Temperature -15°C~60°C, Relative Humidity 0-95% No condensates, Acoustic Noise 40 dBA @ 1 Meter, Cooling Forced air cooling by the internal fans, Input Socket IEC C13, Output Socket IEC C14, No of output sockets 3 No's, Rated Input Voltage 208/220/230/240 Vac, Maximum working input voltage range 160 to 300 Vac @ 100% Load, 100 to 300 Vac @ 50% Load, Input Power Factor 0.99, Input THDi% 5%, Generator Set Yes 1.5 x UPS Capacity, Rated kVA 1000 VA, Rated kW 800 Watts, Load type Resistive load/ lagging load/ nonlinear load/ transformer load/ lighting load, Load power factor range 0.5~1 lagging, Load Crest Ratio 3:1, Online Efficiency 88%, Rated Battery Voltage 36 Vdc, Battery Type VRLA (Valve Regulated Lead Acid Battery), 12VDC, Battery backup Back UP : 936VAH, Maximum charging current 10 Amps, ECO Mode Available, Communication (Independent SCI) Available, Intelligent Card slot (Independent SCI) Available, OVCD Available, EPO Function Available, Intelligent Fans Speed control Available, Auto restart function Available, Cold start Available complete in all respects as approved and desired by the Engineer in-charge at site. |
| 108 | Supply and erection of fire survival cable for fire alarm & PA system with annealed stranded copper conductor, fire resistant mica tape wrapped (at 950°C for 180 minutes), XLPE insulated, LSHZ (low smoke & zero halogen) bedding, LSZH (low smoke & zero halogen) red outer sheath, galvanized steel wire armour, 600/1000 volts grade, Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ, Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) left bare in pipe or casing or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 109 | Fire Survival cable 2Core x 1.5 sq.mm |
| 110 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 111 | Overall size 1.5sq.mm (48/0.20mm), 2Core |
| 112 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 113 | Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed |
| 114 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 115 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail