| 1 | Taking down carefully aluminum/copper point wiring (light ,fan, socket any type, power, bell etc.) complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fittings etc) and removing the material from site and making good the disturbed surfaces of walls ceiling etc complete all as directed.( Note: Credit for above items should be made as per credit Schedule separately) |
| 2 | Taking down carefully by submain wiring of any type complete and making good disturbed sufaces to match with the existing surfaces all as directed by Engineer-in-Charge. |
| 3 | Taking down old unserviceable existing SPN/TPN DBs / enclousers any size and type / any descriptions as iron sheet scrap including MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed |
| 4 | M & L for Point wiring for One light point controlled by one switch 5 amp with 1.5 sqmm (nominal area) single core PVC insulated sheathed (FRLSH) cable, 1100 volts grade, multi-stranded copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20 mm dia med gd) and its all accessories complete concealed in wall and modular flush metal boxes with modular cover plates & frames for mounting modular switches, sockets, regulators etc. including earth wire of PVC insulated (FRLSH) copper conductor multistranded of 1.5 sqmm size in green colour complete all as specified in current SSR Part-I & II & directed by the Engineer-in-Charge. |
| 5 | All as per item No.4 here-in-above but for One wall/exhaust fan point controlled by one switch 5 amp. |
| 6 | All as per item No.4 here-in-above but for One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified. |
| 7 | All as per item No.4 here-in-above but for One 5 Amp 5 pin socket outlet point on independent board with other switches including earth wire as specified. |
| 8 | All as per item No.4 here-in-above but for One bell point controlled by one push button. |
| 9 | All as per item No.4 here-in-above but for 3 pin/ 5 pin, sockets outlet,15 amps with 4.0 sqmm PVC insulated & unsheathed (FRLSH), multi-stranded copper condutor cable, independent, Point wiring complete all as specified and as directed . |
| 10 | Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete. |
| 11 | Supply and Fixing Modular bell Push switch 6 Amps with indicator single pole one-way, 1 Module . |
| 12 | Supply and Fixing Modular switch 16 Amp single pole one way,1 Module all as specified. |
| 13 | Supply & Fixing Modular fan Regulator electronic step type complete all as specified. |
| 14 | Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps, combined 2 Module complete all as specified. |
| 15 | Supply and Fixing Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete. |
| 16 | S&F Ding Dong Calling Bell 230 V Single phase complete all as specified and directed. |
| 17 | Supply and fixed in repair ceiling rose surface bakelite 65mm x 50mm three terminals complete . |
| 18 | S&F Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten |
| 19 | S&F indoor decorative ultra slim surface/ wall mounted LED batten tube light fitting complete, 1x 20 watt with polycarbonate channel housing & integrated electronic driver, energy efficient, 140V-270 volts, co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with pvc insulated pvc sheathed twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. |
| 20 | M & L for Sub Main Wiring for DB to DB with two runs single core 10 Sqmm PVC insulated unsheathed (FRLSH) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete concealed in wall/roof with and including 10 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge.(02 run 10 Sq mm single core cable, one run of 10 Sq mm earth wire & One run of PVC conduit will measured as one RM). |
| 21 | S&F Ceiling Fan having sweep 1200 mm, 3-blades of aerodynamic ABS material (dust & mark resistant), energy-efficient BLDC motor single phase with inverter technology consuming not more than 28 W at rated speed of approx. 280 RPM and air delivery not less than 245 m³/min with service value not less than 7.00. The fan shall be supplied without LED under light and in Pearl White colour finish only. The fan shall include RF remote control with timer (up to 8 hours), sleep/breeze modes, and memory function. Noise level shall be whisper-quiet. The fan shall have 5-Star energy rating, 2 years manufacturer’s warranty, and be BIS/ISI marked wherever applicable. Installation shall be carried out by authorized service personnel with all accessories complete as per manufacturer’s standard. Note: Old fan should be deposited in MES store yard. |
| 22 | M&L vertical load line distribution board factory made and tested made of sheet metal enclosure powder coated suitable for upto MCCB 100A triple pole and neutral as incomer and outgoing MCBs, 4 way TPN with rated busbar 415 volts,neutral link, Blanking plates (Without MCCB/MCBs) IP 43 (double door type) ISI marked suitable for G Frame MCCB 160 Amp as incommer of Make: Havells Cat Pt No DHDLVDRWAOF04 of Havells or its equivalents (Note MCCB Price should be measured and paid seperately) |
| 23 | M&L vertical load line distribution board factory made and tested made of sheet metal enclosure powder coated suitable for MCCB 160A triple pole and neutral as incomer and outgoing MCBs, 6 way TPN with rated busbar 415 volts,neutral link, Blanking plates (Without MCCB/MCBs) IP 43 (double door type) ISI marked suitable for G Frame MCCB 160 Amp as incommer of Make: Havells Cat Pt No DHDLVDOBGSFE06 of Havells or its equivalents |
| 24 | M&L vertical load line distribution board factory made and tested made of sheet metal enclosure powder coated suitable for MCCB 160A triple pole and neutral as incomer and outgoing MCBs, 12 way TPN with rated busbar 415 volts,neutral link, Blanking plates (Without MCCB/MCBs) IP 43 (double door type) ISI marked suitable for G Frame MCCB 160 Amp as incommer of Make: Havells Cat Pt No DHDLVDOBGSFE12 of Havells or its equivalents |
| 25 | Supply & fixed in repair of MCCB 63-100 Amps, breaking cap 25 KA, 3 Pole, 415V complete including taking down old MCBs all as specified and directed. |
| 26 | Supply & fixed in repair of MCCB 125 Amps, breaking cap 25 KA, 3 Pole, 415V complete including taking down old MCBs all as specified and directed. |
| 27 | Supply & fixed in repair of MCCB 160 Amps, breaking cap 36 KA, 3 Pole, 415V complete including taking down old MCBs all as specified and directed. |
| 28 | Supply & fixed in repair of MCCB 160 Amps, breaking cap 36 KA, 4 Pole, 415V complete including taking down old MCBs all as specified and directed. |
| 29 | S&F MCB distribution board, SPN 12 way, double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified. |
| 30 | S&F MCB distribution board, SPN 8 way, double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified. |
| 31 | S&F MCB distribution board, SPN 4 way, double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified. |
| 32 | S&F MCB SPN, 32 Amps, 'C' series, breaking cap 10 kA, 240V in MCB DB complete with electrical connection all as specified and directed. |
| 33 | S&F MCB SPN, 40-63 Amps, 'C' series, breaking cap 10 kA, 240V in MCB DB complete with electrical connection all as specified and directed. |
| 34 | S&F MCB SP, 6-32 Amps, 'C' series, breaking cap 10 kA, 240V in MCB DB complete with electrical connection all as specified and directed. |
| 35 | S&F MCB SP, 40 Amps, breaking cap 10 kA, 240V in MCB DB complete with electrical connection all as specified and directed. |
| 36 | M&L for earthling complete with galvanized steel earth plate eletrode 60x60 cm x6.3 mm thick burred directly in ground (earth pit not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Metrs below normal ground level connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthling test point all as specified and indicated including testing on completion including excavation and arth work PCC pit & RCC pit over funnel with watering pipe wire mesh GI protection pipe etc complete. |
| 37 | All as per item no 36 but for GI Strip 25x4mm |
| 38 | Taking down carefully by XLPE Cable/service connection of any type |
| 39 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out all as specified and as directed by Engr-In-Charge. |
| 40 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified. |
| 41 | Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified. Please Enable Macros to View BoQ information |
| 42 | Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified. Please Enable Macros to View BoQ information |