| 1 | B/R WORKS :M&L for surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specifed and directed. |
| 2 | M&L for excavation in trenches n.exc 1.5m wide and n.exc 1.5m in deepth; for foundation etc or for shafts, wells, cesspits, manhole, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specifed and directed. |
| 3 | M&L for PCC 1:4:8 type D-2 (using 40mm graded agg) as in foundation, filling and mass concrete complete all as specifed and directed. |
| 4 | M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specifed and directed. |
| 5 | All as per item No 4 above but 6mm to 8mm dia complete all as specifed and directed. |
| 6 | All as per item No 4 above but 5mm dia and over and including 10mm dia in stirrups spacers and binders complete all as specifed and directed. |
| 7 | M&L for RCC M-25 as in foundation, including rafts, footings, foundation beams; plinth beams; bases for coloumns, etc basement slabs under reamed piles and mass concrete.(Note : Design Mix shall be carried out from CTL Jorahat/NABL certified lab) complete all as specifed and directed. |
| 8 | M&L for RCC M-25 as in columns, pillars, piers, posts and struts.(Note : Design Mix shall be carried out from CTL Jorahat/NABL certified lab) complete all as specifed and directed. |
| 9 | M&L for RCC M-25 (Design Mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. (Note : Design Mix shall be carried out from CTL Jorahat/NABL certified lab) complete all as specifed and directed. |
| 10 | M&L for RCCM-25 (Design Mix) as in chajjas. (Note : Design Mix shall be carried out from CTL Jorahat/NABL certified lab) complete all as specifed and directed. |
| 11 | M&L for RCC M-25 (Design Mix) as in beams, cantilvers, bressummers, lintels over 1.5m span.(Note : Design Mix shall be carried out from CTL Jorahat/NABL certified lab) complete all as specifed and directed. |
| 12 | M&L for Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specifed and directed. |
| 13 | M&L for Use and waste of formwork to sides of pillars posts, struts, piers, columns and stanchions finished the suface rough complete all as specifed and directed. |
| 14 | M&L for Use and waste of formwork to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc complete all as specifed and directed. |
| 15 | M&L for Use and waste of formwork to chajjas, troughts and similar items including edges complete all as specifed and directed. |
| 16 | M&L for form work with fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work nexc 200mm thick (horizontal or sloping) complete all as specifed and directed. |
| 17 | Supply only water proofing compound complete all as specifed and directed. |
| 18 | M&L for brick work with sub class `B' bricks well burnt straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specifed and directed. |
| 19 | M&L for brick work with sub class `B' bricks well burnt straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specifed and directed. |
| 20 | S&F powder coated aluminium anodised frame for doors, windows etc with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 21 | S & F Aluminium anodised powder coated shutter weight 0.55 kg/m including necessary jointing cleats, glazing rubber beading/ glazing clips and packing handles 02 Nos in each door pannels all as specified and directed. |
| 22 | S&F Anodised aluminium powder coated window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including all necessary fittings like hinges joining cleats, glazing clips,moving roller, rubber packing, anodised aluminium snap beading, screws etc. complete all as specifed and directed. |
| 23 | Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) (A) Area not exceeding 2.00 sqm each complete all as specifed and directed. |
| 24 | S & F Sheet glass 4.8mm thick frosted on one side,ordinary quality and glazing with oil putty/necessary rubber beading in square exc 0.5 sq. m in each pane complete all as specifed and directed. |
| 25 | S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specifed and directed. |
| 26 | M&L for hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface using broken stones complete all as specifed and directed. |
| 27 | M&L 40 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) as damp proof course to horizontal or vertical surfaces including necessary form works, applying evenly a coat of blown type bitumen at 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm including 150 micron thick polythene film laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all as specifed and directed. |
| 28 | M&L PCC 1:4:8 type D-2 75mm thick as in sub base of floor complete all as specifed and directed. |
| 29 | M&L for non skid coloured joint free tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick in CM 1:6 complete all as specifed and directed. |
| 30 | All as per ser No 29 but on vertical surfaces such as skirting , dado risers to steps over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specifed and directed. |
| 31 | M&L cement concrete 75mm thick 1:2:4 type B-2 using 40mm graded stone aggregate as in pathways/hardstanding laid in alternate ways, each panel not exceeding 3.00 Sqm finished the surface even and fair without using extra cement and joint to be filled with Bituminous mastic filling in proportion of Bitumen and sand (1:2) including necessary form work complete all as specified and directed. |
| 32 | M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound, Grade ‘A’ complete all as specifed and directed. |
| 33 | M&L preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer including anty termite treatment complete all as specified and directed. |
| 34 | M & L rendering 15mm thick on cement mortar 1:4 brick or concrete work finished the surface even and smooth without using extra cement with water proofing compound (Note : WPC shall be measured separately) complete all as specifed and directed. |
| 35 | M&L for rendering 5mm thick plaster in CM 1:3 on fair faces of brick or concrete work finished even and smooth without using extra cement as in ceiling complete all as specifed and directed. |
| 36 | M&L for preparation of newly plastered surfaces of walls & applying two coat of distemper oil emulsion over one coat of primner over 3mm thick wall care putty complete all as specifed and directed. |
| 37 | M&L for preparation of new plastered surface of wall Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including 3 mm thick plaster of paris putty on new surfaces complete all as specifed and directed. |
| 38 | M&L for Preparation of new plastered surfaces and applying three coat of white wash on ceiling complete all as specifed and directed. |
| 39 | M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a)Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m n.exc.250m. (b) M&L 25 thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate) finished even and smooth. (c) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight). (d) M&L for 20 mm thick screed bed in cement mortar 1:4 finished even and smooth.(e) Preparing & cleaning of fully dried cement plastered surface. (f) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384. (g) A layer of APP based polymeric membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (h) One coat of aluminium paint over APP membrane @0.11Kg/Sqm.Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab complete all as specifed and directed. |
| 40 | S&F in repairs for Draperly rod /Harrison rails of stainless steel of 20mm dia with fixing brackets , stops, rollers and rings etc complete all as specifed and directed. |
| 41 | M&L Cement concrete 1:3:6 type C-1 (20 mm graded agg ) in surface channels and drains including form workcomplete all as specifed and directed. |
| 42 | M&L Extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc.complete all as specifed and directed. |
| 43 | Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point complete all as specifed and directed. |
| 44 | Returning, filling in, including spreading, leveling, watering & well ramming in layer s not exc 25 cm complete all as specifed and directed. |
| 45 | M&L of earth filling under floor well ramming including watering as required Spreading & leveling in layers n.exc. 25cm thick complete all as specifed and directed. |
| 46 | M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx22mm thick, as in floors etc, over and including 15 mm thick screed bed or bedding in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed. |
| 47 | S&F for Machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment laid over sand cushing complete all as specified and directed.Note :- Sand cushioning will measured and paid seperately. |
| 48 | Supply and laying of sand including spreading, levelling and ramming in layers n.exc. 25 cm thick in each layer complete all as specifed and directed. |
| 49 | M&L Pre-cast (Factory casted) cement concrete Kerb stone casted in PCC (1:2:4) Type B-1 using 20mm graded stone aggregates with plan or interlocking joints (as directed) with solid blocks, exc. 10 cm in width and setting and jointed in cement mortar 1:6, complete all as specifed and directed. |
| 50 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil complete all as specifed and directed. |
| 51 | S&F for steel work in tubular section for purlin/rafters etc including special shaped washer etc. complete using induction butt welded tubes conforming to I.S. 1161-1998 grade St- 240 complete all as specifed and directed. |
| 52 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc gde Fe-410 W (Gde E- 250) quality A complete all as specifed and directed. |
| 53 | M&L for applying two coat of Synthetic enamal paint over a coat of red oxide primer on new steel based surfaces exc.10cm width or girth including preparation complete all as specifed and directed. |
| 54 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings, cooler stands (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floor in PCC 1:2:4 type B-0 to match the existing floor complete all as specifed and directed. |
| 55 | S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 56 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specifed and directed. Please Enable Macros to View BoQ information |
| 57 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specifed and directed. Please Enable Macros to View BoQ information |