Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil items:Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth within all lead and lift as directed by Engineer-in-Charge. a) All kinds of soil as per entire satisfaction and direction of Engineer-in-charge. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 3 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for :a) Foundations, footings, bases of columns, etc. for mass concrete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for :a)Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for :a) Suspended floors, roofs, landings, balconies and access platform as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for :a) Shelves (Cast in situ) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for :a) Lintels, beams, plinth beams, girders, bressumers and cantilevers as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for :a) Columns, Pillars, Piers, Abutments, Posts and Struts as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for :a) Stairs, (excluding landings) except spiral-staircases as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for :a) Edges of slabs and breaks in floors and walls i) Under 20 cm wide as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. a) Thermo-Mechanically Treated bars of grade Fe-500D or more as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 14 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Nothing Extra cement content shall be payable separately. In case the cement content in design mix is more than specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cementa) All works upto plinth leveli)Concrete of M30 grade with minimum cement content of 350 kg /cum as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 15 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Nothing Extra cement content shall be payable separately. In case the cement content in design mix is more than specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.a) All works above plinth level upto floor V leveli)Concrete of M30 grade with minimum cement content of 350 kg /cum as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 16 | Providing and laying autoclaved aerated Concrete (AAC) blocks masonry with 100mm / 125 mm thick with Grade 1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 17 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 18 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. a) Granite stone slab all colour and texture except black, Cherry/ Ruby redi) Area of slab upto 0.50 sqm as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 19 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. a) Granite stone slab all colour and texture except black, Cherry/ Ruby redi) Area of slab over 0.50 sqm as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 20 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. a) Granite work as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 21 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 22 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 23 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 24 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 25 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) a) 250x10 mm as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 26 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 27 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 28 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. a) Single rubber stopper as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 29 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : a) For fixed portioni) Powder coated aluminium (minimum thickness of powder coating 50 micron) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 30 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : a) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).i) Powder coated aluminium (minimum thickness of powder coating 50 micron) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 31 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): a) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 32 | Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge a) Powder coated minimum thickness 50 micron aluminium as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 33 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: a) Profile Bi) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 34 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. a) Hot finished welded type tubes as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 35 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 36 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 37 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. a) Glazed Vitrified tiles Matt/Antiskid finish of sizei) Size of Tile 600 x 600 mm as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 38 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. a) 110 mm diameter as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 39 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) Coupleri) 110mm as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 40 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) Bend 87.5°i) 110 mm bend as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 41 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) Shoe (Plain)i) 110 mm Shoe as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 42 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 43 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :a) Ridges plain (500 - 600mm) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 44 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :a)Flashings/ Aprons.( Upto 600 mm) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 45 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.a) GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 46 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main ’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x 28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening “for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 47 | 12 mm cement plaster of mix : a) 1:6 (1 cement: 6 fine sand) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 48 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:6 (1 cement: 6 fine sand) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 49 | Finishing walls with Acrylic Smooth exterior paint of required shade : a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: a) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 52 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 53 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 54 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : a) Flat back wash basin of size 630x450 mm as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 55 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.a) Semi rigid pipe i) 32 mm dia as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 56 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 57 | Providing and fixing toilet paper holder : a) C.P. brass as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 58 | Providing and fixing soil, waste and vent pipes : a) 100 mm dia.i) Sand cast iron S&S pipe as per IS: 1729 as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 59 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 60 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 61 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anticorrosive bitumastic paint, cutting chases and making good the wall:a)15 mm dia. nominal bore as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 62 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anticorrosive bitumastic paint, cutting chases and making good the wall:a)20 mm dia. nominal bore as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 63 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External worka)25 mm dia. nominal bore as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 64 | Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 :a)150 mm dia. pipe as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 65 | Supplying pig lead at site of work as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 66 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 67 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. a) 15 mm nominal bore as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 68 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. a) 15 mm nominal bore as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 69 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: a) 15mm nominal bore as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 70 | Providing and fixing PTMT grating of approved quality and colour. a) Circular type.i) 100 mm nominal dia as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 71 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: a) 100x100 mm size P typei) With common burnt clay F.P.S. (non- modular) bricks of class designation 7.5 as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 72 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : a) Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 1 16 kg (weight of cover 58 kg and weight of frame 58 kg) :i) With common burnt clay F.P.S. (non- modular) bricks of class designation 7.5 as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 73 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. a) With common burnt clay F.P.S. (non- modular) bricks of class designation 7.5 as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 74 | Electrical items:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit/ casing capping, with modular switch, modular plate, suitable GI/PVC box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group C) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 75 | Wiring for circuit/ submain wiring along with earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 76 | Wiring for circuit/ submain wiring along with earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. as required. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 77 | Supplying and fixing 8 way (4 + 24), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). as required. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 78 | Supplying and fixing 63 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 79 | Supplying and fixing 5A to 32A Rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 80 | Supplying and fixing 63 A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 81 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 82 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 83 | Supplying and fixing two way 5/6 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 84 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 85 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 86 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 87 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 88 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/sub-main wiring/ cable as required.as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 89 | Supplying of 4 Core x 10 Sq. mm of 1.1 KV aluminium conductor XLPE Insulated, PVC inner-sheathed armoured, Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 90 | SITC of 20W (1200 mm) LED Batten With extruded polycarbonate, environmental friendly & energy efficient this linear profile LED lighting fixture provides uniform illumination for brighter light as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 91 | Supply, installation, testing & commissioning of 250 mm sweep PVC body exhaust fan as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 92 | Supplying and making end termination with al lugs for 4C X 10 Sq.mm (10 mm) of PVC Sheathed / XLPE aluminium conductor cable of 1.1 KV Grade as required as per entire satisfaction and direction of Engineer- in - charge including carriage of material in all leads and lifts. |
| 93 | Supplying installation testing and commissioning of Three phase electronic energy meter (HPSEBL tested) 10-60 A, class 1.0 accuracy, suitable for Three phase (415 - 440) V AC supply, including connections, accessories and making good of surface as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 94 | Supplying and fixing of 12\\"X10\\"X1\\" thick Wooden mounting board duly painted or varnished, complete with necessary fixing arrangements as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail