| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and directed. |
| 3 | Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 4 | M&L for sand cushioning with dry clean sand 15cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for payments. |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, classClass LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed. |
| 6 | S&F in repair,given size bore tubing of 50 mm bore “light grade” in trenches/ on pole for protection of cables complete all as specified and directed. |
| 7 | All as per Ser Item No . 6 above but for 40 mm borecomplete all as specified and directed. |
| 8 | All as per Ser Item No . 6 above but for 80 mm bore complete all as specified and directed. |
| 9 | Supply ,laying & testing in trenches / pole of 150 sq mm 3.5 core cable XLPE insulated screened PVC bedded galvanised steel strip or wire, armoured electric power cable (heavy duty) with stranded aluminium conductor 11000 volts earthed grade of cross sectioal area wth all fitting accessories eg. lux etc. specified and directed by engr in charge of given size complete all as specified and directed. |
| 10 | All as per Ser Item No. 7 above but for 95 sq mm 3.5 core complete all as spcified and directed |
| 11 | All as per Ser Item No. 7 above but for 70 sq mm 3.5 core complete all as spcified and directed |
| 12 | All as per Ser Item No. 7 above but for 50 sq mm 3.5 core complete all as spcified and directed |
| 13 | All as per Ser Item No. 7 above but for 35 sqmm 3.5 corecomplete all as spcified and directed |
| 14 | All as per Ser Item No. 7 above but for 25 sqmm 3.5 core complete all as spcified and directed |
| 15 | All as per Ser Item No. 7 here-in-before but for 16 sq mm 4 core complete all as spcified and directed |
| 16 | All as per Ser Item No. 7 here-in-before but for 10 sqmm 4 corecomplete all as spcified and directed |
| 17 | All as per Ser Item No. 7 here-in-before but for 25 sqmm 2 core complete all as spcified and directed |
| 18 | All as per Ser Item No. 7 here-in-before but for 16 sqmm 2 corecomplete all as spcified and directed |
| 19 | All as per Ser Item No. 7 here-in-before but for 10 sq mm 2 core complete all as spcified and directed |
| 20 | Dismantling of old/rusted aluminium conductor steel reinforced of any size and removing the same from site of work complete all as specified and directed. |
| 21 | Dismantling of old/rusted Cross arms,bracings, supports, clamps and back plates including nut bots etc any size and removing the same from site of work complete all as specified and directed. |
| 22 | Dismantling insulators any type, any size complete all as specified and directed. |
| 23 | Supply, install, testing and commissioning outdoor type LT panel of size 1m x 1m x 0.5m, with IP 65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door painted with powder coated paint and aluminium bus bar of 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (FP-I,FP-II & FP-IV)Note : Foundation to be included in the quoted priceIncoming :-(a) MCCB, 4 Pole, 250A, 415 V, 36 kA. (I/C). Thermal magnetic adjustable type(b) multifunction 3 phase meter duly showing voltage,amps,kw,PF,frequency,kva & kVar.(c) aluminium bus bar 4 strip -400 amps (length should not be less than 0.7 m)(d) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etcOutgoing :-(a) MCCB, 4 Pole, 200 Amp, 415 V, 36 kA - 02 No Thermal magnetic adjustable type(b) MCB,TPN, 100A, 240 V, 18 kA - 02 Nos. (c) MCB, TPN, 63 A, 240 V, 18 kA - 04 No. Please Enable Macros to View BoQ information |
| 24 | Supply, install, testing and commissioning outdoor type LT panel of size 1m x 1m x 0.5m, with IP 65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door painted with powder coated paint and aluminium bus bar of 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (FP-I,FP-II & FP-IV)Note : Foundation to be included in the quoted priceIncoming :-(a) MCCB, 4 Pole, 250A, 415 V, 36 kA. (I/C). Thermal magnetic adjustable type(b) multifunction 3 phase meter duly showing voltage,amps,kw,PF,frequency,kva & kVar.(c) aluminium bus bar 4 strip -400 amps (length should not be less than 0.7 m)(d) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etcOutgoing :-(a) MCCB, 4 Pole, 200 Amp, 415 V, 36 kA - 02 No Thermal magnetic adjustable type(b) MCB,TPN, 100A, 240 V, 18 kA - 02 Nos. (c) MCB, TPN, 63 A, 240 V, 18 kA - 04 No. Please Enable Macros to View BoQ information |