| 1 | Item Description |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with dismantling as required. -Group A |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with dismantling as required. - Group B |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with dismantling as required. - Group C |
| 5 | Wiring for circuit/submain wiring alongwith earthwire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduit as required 2X2.5 sq. Mm.+1X2.5 sq mm earth wire |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.-2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 7 | Supply and fixing following way,single pole and neutral,sheet steel,MCBdistribution board,240 volt,on surface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar din bar,interconnections,powder painted including earthing etc.as required ( but without MCB/RCCB/Isolator)12 way double door |
| 8 | Supply and fixing following way,single pole and neutral,sheet steel,MCBdistribution board,240 volt,on surface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar din bar,interconnections,powder painted including earthing etc.as required ( but without MCB/RCCB/Isolator)16 way,single door |
| 9 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral |
| 11 | Supplying and fixing of following rating double pole(single phase and nuetral),240 volts ,residuat breaker(RCCB) having sensitivity current 30mA in the existing MCB DB mplete with connections, testing and commissioning etc as required 63Amps |
| 12 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel,making connections etc as required 100 Amp TP&N |
| 13 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel,making connections etc as required 200 Amp TP&N |
| 14 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 15 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 16 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 17 | Supplying and fixing two module stepped type/continuous type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 18 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 19 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 20 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) |
| 21 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 22 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 23 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a. 5/6 amps switch |
| 24 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.b. 15/16 amp switch |
| 25 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.c. 3 pin 5/6 amp socket outlet |
| 26 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.d. 6 pin 15/16 amp socket outlet |
| 27 | Supplying and fixing of 100 Amps 415 Volts Step Type Busbar Chamber Box |
| 28 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |