| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 sqm complete all as specified and directed. |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed. |
| 3 | Taking down shutters of any description exc 1 Sqm but n exc 2 Sqm each complete all as specified and directed. |
| 4 | Dismantling of water tank RCC/HDPE/Ferrocrete etc of size 250 Ltrs to 500 Ltrs capacity, removal from site, complete all as specified and directed. |
| 5 | Dismantling of water tank RCC/HDPE/Ferrocrete etc of size 1000 Ltrs capacity, removal from site, complete all as specified and directed. |
| 6 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises, complete all as specified and directed. |
| 7 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness, below or above ground level, complete all as specified and as directed. |
| 8 | Demolition of brick work or stone masonay built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles and removal of debris/rubbish off the premises etc complete all as specified and directed. |
| 9 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, rubbish off the premises complete all as specified and directed |
| 10 | Taking up or down steel tubing 15mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 11 | Taking up or down steel tubing 20mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 12 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed. |
| 13 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed. |
| 14 | M&L for preparation of new plastered surface of Ceiling by applying three coats of white wash, complete all as specified & directed |
| 15 | Preparing new plastered surface of wall and appying two coats of cement base paint mixed with silicon based water repellent compound over a coat of primer by roller/brush including curing complete all as specified & as directed. |
| 16 | Preparation of new plastered or unplastered surfaces of walls applying two coats of oil bond distemper paint over a coat of priming paint, complete all as specified and directed. |
| 17 | M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 18 | Rotational moulded polythylene 1000 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position complete all as specified and directed. |
| 19 | Rotational moulded polythylene 500 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position complete all as specified and directed. |
| 20 | Brick work with fly ash (Old Size bricks) sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and as directed. |
| 21 | PCC type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection 75mm thick laid in slope finished even and fair including making joints not more than 2.5 m (or as directed) and at corner, filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed. |
| 22 | 5mm thick rendering on concrete surface of ceiling, chajjas etc. in CM 1:3 finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 23 | 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 24 | M&L for rendering 10mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas, roof projections etc, including taking out peeled off plaster / concrete if required and making surface in true line, true shape and finishing the surface smooth without using extra cement complete all as specified and directed. |
| 25 | 15mm thick rendering cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with WPC finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid for separately. |
| 26 | S&F in repairs 300 mm mild steel hydrulic door closer hydraulically regulated designation No-3 , universal type , suitable foor door shutters of 851 to 1200mm in width and of weight between 61 to 80 kg complete all as specified and directed. door closer, complete all as specified and directed. |
| 27 | S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor Overall length of cover plate 150mm, fixed in floor complete all as specified & directed. |
| 28 | Marble work 12-15mm thick (table rubbed and polished) in cooking plateform, window cill, steps, stair case trade & riser etc in 15 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Bhaislana Zebra including dismantiling complete all as specified & directed. |
| 29 | M&L for Round chamfering to the edges of marble/granite slabs not exc 15 mm wide complete all as specified and directed. |
| 30 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 31 | M&L for PCC 1:2:4 type B-0 ( using 12.5mm graded crushed stone aggregate) padding as roof mixed with WPC as per manufacturer's instruction, surface finished even and smooth without using extra cement, complete all as specified and directed. Note: WPC shall be measured and paid for separately. |
| 32 | Reinforced cement concrete 1:2:4 type B-0 (using 20 mm graded crushed stone aggregate) as in slabs, kitchen slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork, complete all as specified and directed. |
| 33 | M&L for PCC 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, benching, copings, kneelers, apex stones, bed plates, kerbs , fillet, gola, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed (Also applied in broken RCC chajjas and roof protection) |
| 34 | M&L 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth mixed with liquid water proofing compound as per manufacturer instruction including raking out joingts, hacking for key, scrubbing down with water etc complete all as specified and directed.Note : WPC shall be measured separately. |
| 35 | Material and labour for preparation of surfaces and apply first of coat Fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflective Index (SRI) of 100-110, having minimum elongation of 350%, tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure & reduce surface temperature upto 10 degree Celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry. Apply second of undiluted coat @ 0.45 ltr/sqm. Apply third and final coat undiluted @0.45ltr/sqm complete application to be done by the manufacture or authorised applicator complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 36 | Material and labour for preparation of surfaces and apply first of coat Fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflective Index (SRI) of 100-110, having minimum elongation of 350%, tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure & reduce surface temperature upto 10 degree Celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry. Apply second of undiluted coat @ 0.45 ltr/sqm. Apply third and final coat undiluted @0.45ltr/sqm complete application to be done by the manufacture or authorised applicator complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |