Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-06-2026 | Corrigendum01 | BOQ | 24-06-2026 |
| Sl. No. | Item Description |
| 1 | Taking down cement plaster from brick walls/soffits of roof projections & chajjas /ceilings etc. including racking out joints, hacking for key & scrubbing down with water etc including disposal of rubbish material to any distance out side MOD land complete all as specified and as directed. |
| 2 | Material and labour for rendering/plastering 15 mm thick in CM (1:4) on any face of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 3 | Material and labour for rendering/plastering 15 mm thick in CM (1:6) on any face of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 4 | Material and labour for rendering/plastering 5 mm thick in CM (1:3) on concrete surfaces of ceiling, finished fair and even complete all as specified and as directed. |
| 5 | Material and labour for complete removal of existing treatment of any type/description (any layer) from external/internal wall/ceiling surfaces, soffits/chajja/roof projection surfaces etc., by scraping steel patti or Mechanical sander/grinder machine having suction vaccum Bag (Smart periodical methodology), complete all as specified and as directed. |
| 6 | Material and labour for preparation of new plastered surfaces, surface after complete removal, applying acrylic putty on internal surfaces of walls/ceiling/soffits etc (thickness vary from 1.5 to 2 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using readymade putty, including sanding with wall sander after filling the putty in first coat/second coat to make surface smooth and ready for receiving interior painting complete all as specified and as directed.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.Make of acrylic Putty: - Berger / Asian / Nerolac |
| 7 | Material and labour for applying 02 coats of interior acrylic emulsion paint of approved tint/shade (Company Depot Tinted) @ 8 sq.m/litre/2 coats to wall surfaces (new or old prepared internal surface after complete removal and applying putty) over and including a coat of interior primer @ 11 sq.m/litre/1 coat (primer shall be same make as acrylic emulsion paint), paint and primer applying by using paint roller brush complete all as specified and as directed.Brand and Make of interior acrylic emulsion paint: - Bison Acrylic Emulsion of Berger / Tractor Emulsion of Asian / Beaty Smooth of Nerolac Brand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 8 | Material and labour for applying 02 coats of exterior acrylic emulsion paint of approved tint/shade (Company Depot Tinted) @ 6 sq.m/litre/2 coats to external walls / Soffits of Chajjas / Roof Projections / Cantilevers / Balcony etc. (on new or old prepared external surface after complete removal) over and including a coat of exterior primer @ 11 sq.m/litre/1 coat (primer shall be same make as acrylic emulsion paint), paint and primer applying by using airless spray gun complete all as specified and as directed.Brand and Make of exterior acrylic emulsion paint: - Weather Coat Glow of Berger / Apex Weatherproof of Asian / Excel of Nerolac Brand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 9 | Material and labour for applying 02 coats of interior acrylic emulsion paint of white shade (Company Depot Tinted) @ 7.50 sq.m/litre/2 coats to ceiling surfaces (new or old prepared internal surface after complete removal and applying putty) over and including a coat of interior primer @ 10.50 sq.m/litre/1 coat (primer shall be same make as acrylic emulsion paint), paint and primer applying by using paint roller brush complete all as specified and as directed.Note ;- Complete removal and putty shall be measured and paid separately under respective item of BOQ.Brand and Make of interior acrylic emulsion paint: - Bison Acrylic Emulsion of Berger / Tractor Emulsion of Asian / Beaty Smooth of Nerolac Brand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 10 | Material and labour for preparation of old previously treated surfaces of concrete / chequered tiles / interlocking tiles / kerb stone /Brick of any description not otherwise described over 10cm width or girth, by cleaning the dust and removing all loose particle with using clean cloths, brooms and dry paint brush etc and after preparing the surfaces applying two coats of washable floor paint, coverage per sqm @ as per manufacturer’s brochure, of approved tint/colour (one colour or alternative any colour) complete as specified and as directed.Make : - INDIGO Platinum Series / Asian paints Apex Floor Guard Exterior Paint / Dulux Floor Plus |
| 11 | Dismantling of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area at any distance as direccted from the site complete all as specified and as directed |
| 12 | Material and labour for 25mm thick PCC in cement mortar (1:2:4) type B0 using 12.5mm graded stone aggregate as in sub base, the surface finished fair/rough complete all as specified and directed |
| 13 | Material and labour for 15 mm thick bedding layer (screed bed for floor tiles) in cement mortar (1:6) in grey cement including mixing of liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50kg, and finish the surface even and fair/rough to receive the tile complete all as specified and as directed.Note :- (i) Liquid Water Proof Compound shall be measured and paid separately as supply only under respective item of BOQ. (ii) The labour element of mixing of Liquid Water Proof Compound is included in this item. |
| 14 | Material and labour for 10 mm thick bedding layer (screed bed for skirting tiles) in cement mortar (1:4) in grey cement including mixing of liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50kg, and finish the surface even and fair/rough to receive the tile complete all as specified and as directed.Note :- (i) Liquid Water Proof Compound shall be measured and paid separately as supply only under respective item of BOQ. (ii) The labour element of mixing of Liquid Water Proof Compound is included in this item. |
| 15 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 16 | Material and labour for providing Double charge vitrified coloured tiles (approved light shade), area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, having thickness not less than 8mm, premium quality having water absorption less than 0.08%, straight edge, stain free, glossy finish, laid as in floors and skirting, set and jointed in neat cement slurry, joint filled/pointed with white or coloured cement to match the shade of tile, including necessary cutting as per site requirement, complete all as specified and as directed. |
| 17 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position and including disposal of rubbish material to any distance out side MOD land complete all as specified and as directed. |
| 18 | Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 19 | Material and labour for Coloured chequered cement concrete tiles of size 30cm x 30cm x 25mm thick laid as in floor/path, set and jointed in neat cement slurry @ 3.00 Kg / Per Sqm, tiles made by table vibratory method using PU/rubber mould, with grey cement and colour pigment, colour / pattern as approved, complete all as specified and as directed. |
| 20 | Material and labour for machine cut 18-20mm thick (minimum), Kota stone slab (size of slab not less than 550x500mm for flooring including 75mm wide white marble strips (border) all-around of room/verandah, set & jointed in and including neat cement slurry, laid over and including 15mm thick cement mortar (1:4) screed bed, and pointing in white cement mixing with pigment to match with shade of slab, including rubbing /grinding and polishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed. |
| 21 | Material and labour for machine cut 15-18mm thick, Kota stone slab as in skirting, dado and on pillar, set & jointed in and including neat cement slurry, laid over and including 10mm thick cement mortar (1:3) screed bed, and pointing in white cement mixing with pigment to match with shade of slab, including machine cutting to make it square or rectangular as per site complete all as specified and as directed. |
| 22 | Material and labour 18-20mm thick approved shade Granite, machine cut, duly factory grinding and polishing (table rubbed and polished) as in cooking platform, in steps, jambs, for counter sunk wash basin and like or where directed, set & jointed in and including neat cement slurry, laid over and including 15mm thick cement mortar (1:4) screed bed, and pointing in white cement mixing with pigment to match with shade of slab, including cutting as required including cleaning and extra polishing if required complete all as specified and as directed.Note : Single piece should be used in steps/jambs/shelves, equal to width of slab, including accommodate the hole for gas pipe in cooking platform and chamfering/rounding the outer edges, nothing extra shall be paid on this account. |
| 23 | Dismantling of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description, stacking serviceable brick for re use if directed and balance removing rubbish from the site complete all as specified and as directed. |
| 24 | Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed |
| 25 | Taking down aluminium chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1 sqm but not exceeding 4Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed. |
| 26 | Taking down aluminium chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 4 sqm but not exceeding 8 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed. |
| 27 | Material and labour for aluminium work for fabrication and fixing of glazed door/window/ventilator side and top hung type with or without sash bars, partition/fixed type etc, made out of aluminium extruded section conforming to IS:733 and IS:1285 (standard tubular sections/ appropriate Z sections and other sections as approved make for chowkhat frame with one or more rebates and door/window frame) any size as directed, powder coated (minimum thickness of powder coating not less than 50 micron) including necessary joining cleats, glazing clips, EPDM rubber/neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings/ Aluminium mongery, Hardware, hinges, pivots, peg stays, suitable handle, tower bolt, sliding door bolt, dash fasteners etc as per site requirement and as per standard Engineering practice, Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified and as directed.Note :- (i) The weight of each section or complete door window including fittings/ Aluminium mongery, Hardwareexcept decorative grill , glass and other material for filling in panel shall be physically ascertained through a board of officers convened by GE and payment shall be made only after the actual weight at site. (ii) Glass, Pre laminated board and Door closer shall be measured and paid separately under respective item of BOQ. |
| 28 | Supply and fixing Silver Anodized Aluminum Grills, anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15 (decorative grill of size of mesh 50mmX50mm or approved design/pattern), fixed to the door/window frame for safety of glass etc, with proper fixing material as per standard Engineering practice, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed.Note :- (i) The weight of aluminium grill shall be physically ascertained through a board of officers convened by GE and payment shall be made only after the actual weight at site. |
| 29 | Supply & fixing aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed (IS Marked) complete all as per direction. |
| 30 | Supply & fixing 6.3 mm thick sheet glass ordinary quality in squares / retangular exceeding 0.5sqm in each pane (aluminium door/window/ventilator/fixed partition) complete all as specified and as directed. Note :- Cost for Aluminium fittings, rubber, beading for securing the glass shall be included in main item of aluminium window/ventilator of BOQ. |
| 31 | Supply & fixing 12mm thick particle board as per IS 12823: 2025, interior grade BWR grade bonded with phenol formaldehyde synthetic resin, pre-laminated both side with decorative choice lamination, fixed to aluminium door frame work all as specified and directed.Note :- Cost for Aluminium fittings and beading for securing the board shall be included in main item of aluminium window/ventilator of BOQ. |
| 32 | Taking down steel rolling shutter complete with all components of any description and area 10Sqm to 15.00 Sqm each, and removing from site complete all as specified and as directed. |
| 33 | Providing & fixing tiled false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main \\"T\\" at 600 mm c/c to form a grid of 1200x600mm and secondary cross \\"T\\" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 3mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights, complete all as specified and directed. |
| 34 | Taking down carefully existing point wiring (light/fan/sockets/bell/power point) any type complete with all accessories such as switch socket with sheet, ceiling rose, lamp holder including rusted/broken concealed conduit, junction and sunken boxes etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed. |
| 35 | Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 20 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and made from 1.6-1.63 mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket / regulator etc, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ. |
| 36 | All as per above point wiring item but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ). |
| 37 | Material and labour for concealed Point wiring for one socket out let 5/6 Amps point controlled by one switch on independent board (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 20 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and made from 1.6-1.63mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket / regulator etc, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ. |
| 38 | Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch on independent board (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 25 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and made from 1.6-1.63mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket / regulator etc, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ. |
| 39 | Supply and fixing modular switch 6Amps, single pole, one way, 1 module complete all as specified and as directed. |
| 40 | Supply and fixing modular switch 16Amps, single pole, one way, 1 module complete all as specified and as directed. |
| 41 | Supply and fixing modular Socket outlet multipurpose type 6 Amp, 2 module complete all as specified and as directed. |
| 42 | Supply and fixing modular Socket outlet multipurpose type 16 Amp, 2 module complete all as specified and as directed. |
| 43 | Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, topline series, 240 volts, 6 Amp, complete all as specified and as directed. |
| 44 | Supply and fixing modular stepped type (1-4/5), electronic Fan regulator, 100-120 watt, 250 volts, (2 module) suitable for any type of fan except BLDC fan complete all as specified and as directed. |
| 45 | Taking down existing LED tube light of any size complete all as specified and as directed. |
| 46 | Supply and fixing LED tube light fitting polycarbonate housing 1 x 20/22 Watt, appx 4 feet long, housing environment friendly, including electric connection with using suitable size flexible copper conductor cable, complete fitting with all accessories and following specifications, complete all as specified and directed. :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 47 | Taking down unserviceable old DB SPN/TPN any type including fittings, MCB etc complete all as specified and directed. |
| 48 | Supply and fixing (concealed flush to wall) factory made VTPN (Vertical type), 4 Way 415V, as per IEC 61439-3, DB (made out of CRCA sheet not less than 1.2mm thick, with copper bus bar rating 200 Amps, with two neutral bar, 2 earth bar and cable tie for cable management, including in built one number MCCB 4 pole 100Amp, 16KA as incomer, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, including making good disturbed surfaces of walls as necessity complete all as specified and directed.Note :- MCB/ISOLATOR for outgoing shall be measured and paid separately under appropriate item of BOQ. |
| 49 | Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way, 240V AC supply, As per IEC 61439-3, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, including making good disturbed surfaces of walls as necessity complete all as specified and directed.Note :- MCB/ISOLATOR for incoming and outgoing shall be measured and paid separately under appropriate item of BOQ. |
| 50 | Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed. |
| 51 | Supply and fixing MCB ‘B’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed. |
| 52 | Disconnecting electric connection and taking down carefully ceiling fan and keep in safe custody. After the building repair work or as directed re-fixing /hanging the ceiling fan including electric connection with and including new flexible copper conductor cable of suitable size from ceiling rose/connector to fan connector, including in replacement new nut bolts, rubber reel, machine screws and split pins etc and normal servicing, cleaning the fan body with blades, canopies, down rod etc. complete all as specified and as directed.Note :- (i) Serial Number of ceiling fan shall also be re-written on fan with red colour permanent marker.(ii) In case of any damage of fan during custody, the contractor will responsible for the same and shall be replaced/repaired by the contractor as per decision of GE without any extra cost to Govt. |
| 53 | Dismantling/ Taking down existing unserviceable sub main wiring any run, any size from and including rusted/broken concealed conduit/casing caping, junction boxes etc and making good disturbed surface of walls/floors etc as per existing complete all as specified and as directed. |
| 54 | Material and labour for surface sub main wiring (Three run i.e. 1 x phase and 1 x neutral and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) with 6 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 25 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, pipe hook/PVC clamps etc., for independent circuit from panel/DB to sheet metal enclosure complete all as specified and as directed.Note :-Three run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. |
| 55 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6-6.3 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto 7.5 mtr length, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embedded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 56 | Supply, installation/lowering, connecting commissioning and testing of Horizontal type open well Submersible pump set, complete with motor (Close-coupled) and required accessories, of capacity 5 HP, 3 Phase, 415V AC, 50 Hz, RPM 2800, designed for a discharge minimum 40 meter head, pump with minimum 600 LPM (or as per OEM recommendation), High-grade Copper winding and advanced thermal protection to prevent motor burnout, including inlet SS Water Cylindrical Submersible Pump Strainer and out let connections required to connect the pump with pipes of any size/type as per existing, complete all as specified and directed. Note:- PCC Foundation if required for fixing and outlet delivery pipe as required same shall be measured and paid separately under appropriate item of BOQ). |
| 57 | Supply, installation/lowering, connecting commissioning and testing of Horizontal type open well Submersible pump set, complete with motor (Close-coupled) and required accessories, of capacity 10 HP, 3 Phase, 415V AC, 50 Hz, RPM 2800, designed for a discharge minimum 50 meter head, pump with minimum 600 LPM (or as per OEM recommendation), High-grade Copper winding and advanced thermal protection to prevent motor burnout, including inlet SS Water Cylindrical Submersible Pump Strainer and out let connections required to connect the pump with pipes of any size/type as per existing, complete all as specified and directed. Note:- PCC Foundation if required for fixing and outlet delivery pipe as required same shall be measured and paid separately under appropriate item of BOQ) |
| 58 | Supply, installation/lowering, connecting commissioning and testing of Horizontal type open well Submersible pump set, complete with motor (Close-coupled) and required accessories, of capacity 20 HP, 3 Phase, 415V AC, 50 Hz, RPM 2800, designed for a discharge minimum 80 meter head, pump with minimum 600 LPM (or as per OEM recommendation), High-grade Copper winding and advanced thermal protection to prevent motor burnout, including inlet SS Water Cylindrical Submersible Pump Strainer and out let connections required to connect the pump with pipes of any size/type as per existing, complete all as specified and directed. Note:- PCC Foundation if required for fixing and outlet delivery pipe as required same shall be measured and paid separately under appropriate item of BOQ) |
| 59 | Supply & fixing GI pipe flanged type medium grade of size 65 mm bore as a outlet delivery pipe connected to open well Submersible pump set including fittings, elbow, reducer, nut bolts, gasket etc., fixing arrangement as per site requirement complete all as specified and directed |
| 60 | Supply & fixing GI pipe flanged type medium grade of size 40 mm bore as a outlet delivery pipe connected to open well Submersible pump set including fittings, elbow, reducer, nut bolts, gasket etc., fixing arrangement as per site requirement complete all as specified and directed |
| 61 | Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in foundation for open well Submersible pump set, benching/coping & similar work etc including slightly rounded or chamfered angles and necessary form work as required at site etc. complete all as specified and as directed. |
| 62 | Supply and fixing Mild steel screw bolts, size and length of bolt as per site requirement, (machine made for grouting in PCC foundation for holding the pump motor) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and as directed. |
| 63 | Supply and fixing copper cable 6 Sqmm x 3 Core flexible flat/round cable, copper conductor multistrand, PVC insulated and overall PVC sheathed, 1100 volt, for connection from starter to motor pump complete all as specified and as directed. |
| 64 | Supply and fixing copper cable 10 Sqmm x 3 Core flexible flat/round cable, copper conductor multistrand, PVC insulated and overall PVC sheathed, 1100 volt, for connection from starter to motor pump complete all as specified and as directed |
| 65 | Supply, installation, connecting commissioning and testing DOL starter Suitable for 3-phase, 415V, 50Hz submersible motor pumps up to 20 HP all in accordance with latest IS/IEC 60947-4-1 specifications, economical model including powder-coated sheet metal enclosure ( IP54/56), incorporating Definite purpose heavy-duty contactor for reliable switching, Adjustable thermal overload relay 20-32 amps, Dry run protection, built-in protection phase preventor for protection against reversal and single phasing, digital Analog ammeter to monitor motor current and voltmeter, operation with push buttons (Start/Stop) and LED indicator for \\"Motor On\\" status, including all other accessories and fixing arrangement along wall /pole, complete all as specified and directed. |
| 66 | Supply, installation, connecting commissioning and testing DOL starter Suitable for 3-phase, 415V, 50Hz Self-Priming Monoblock Centrifugal motor pump 5 HP all in accordance with latest IS/IEC 60947-4-1 specifications, economical model including powder-coated sheet metal enclosure (IP54/56), incorporating Definite purpose heavy-duty contactor for reliable switching, Adjustable thermal overload relay 9-14 amps, Dry run protection, built-in protection phase preventor for protection against reversal and single phasing, digital Analog ammeter to monitor motor current and voltmeter, operation with push buttons (Start/Stop) and LED indicator for \\"Motor On\\" status, including all other accessories and fixing arrangement along wall /pole, complete all as specified and directed. |
| 67 | Supply, installation, connecting commissioning and testing of Self-Priming Monoblock Centrifugal coupled pump set with motor, Cast Iron (CED coated) impeller (or High-Grade Brass for high corrosion resistance) complete with motor and required accessories, of capacity 5 HP, 3 Phase, 415V AC, 50 Hz, RPM 1500, designed for a discharge minimum 15-24 meter head, pump with minimum 525 LPM, TEFC (Totally Enclosed Fan Cooled) with built-in Thermal Overload Protector (TOP), complete pump set fixed on foundation or on moveable trolley complete all as specified and directed.Note:- PCC Foundation or moveable trolley for fixing as required same shall be measured and paid separately under appropriate item of BOQ) Please Enable Macros to View BoQ information |
| 68 | Supply, installation, connecting commissioning and testing of Self-Priming Monoblock Centrifugal coupled pump set with motor, Cast Iron (CED coated) impeller (or High-Grade Brass for high corrosion resistance) complete with motor and required accessories, of capacity 5 HP, 3 Phase, 415V AC, 50 Hz, RPM 1500, designed for a discharge minimum 15-24 meter head, pump with minimum 525 LPM, TEFC (Totally Enclosed Fan Cooled) with built-in Thermal Overload Protector (TOP), complete pump set fixed on foundation or on moveable trolley complete all as specified and directed.Note:- PCC Foundation or moveable trolley for fixing as required same shall be measured and paid separately under appropriate item of BOQ) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |