| 1 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc., conforming to IS specification including primer coating and enamel painting as per design given by the departmental officers etc., complete as per standard specification. |
| 2 | Supplying , fixing and roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers. |
| 3 | Roofing with Galvanised Corrugated Iron Sheet of 0.8mm thickness (22 Gauge) using 20mm x 6mm G.I bolts and nuts and limpet washers, hook bolts and nuts (of size required) and washers or screws, wooden battens, 50mm x 6mm iron wind ties and white lead etc., complete as per standard specification. |
| 4 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles:The profiles should be three chamber system which provides high insulation properties with outer frame 60mmx55mm with anouter wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25x24x25mm steel reinforcement with a thickness of 1mm to have dimensional stability.Thes ash should be of 60x102mm. The mullion should be of 60x74mm. The profiles should have co-extruded seals. Hardware:All the hardware like friction stays, handles should be screwed with self tapping screws.The handles,locks should be designed so that they cannot be released from outside.Glazing:The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation:The profiles should be cut to length and welded 45 degrees. The windows hould be designed such that the water drainage does not pass through the reinforcement chamber.The window system should be fixed directly to the plastered brick wall using self expanding any lon plug and driving m selectroplated screws into plug. |
| 5 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod with fan clamp with side plates and cross arm of size 450mm (18\\") |
| 6 | Supply of Following Materias etc., Complete. |
| 7 | Single Stove Burner |
| 8 | Cooker |
| 9 | Insect Killar |
| 10 | Anda (Big Size) |
| 11 | Vada Chatti |
| 12 | Silver Buckets |
| 13 | Commercial Refrigerator |
| 14 | Weighing Scale |
| 15 | Wet Grinder |
| 16 | 400 Lit Water Cooler |
| 17 | Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 18 | Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floor sand the oppointed with Water Resistant Tile Epoxy Grout etc.,complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)Vitrified Tiles of Size : 600 x 600 x 8mmVariety : Double Charged |
| 19 | Supplying and painting the walls with two coats of cement paint as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work). |
| 20 | Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 21 | UPVC Pipe (Un-Plasticized Polyvinyl Chloride) UPVC usedfor residential and home applications, water pressure inresidential areas do not normally exceed the maximumtolerance. (50 mm dia) |
| 22 | Earthwork excavation and depositing on bank with initial lead and lift as initial of 10 M and lift of 2 M in narrow trenches for laying of pipes for water supply works in Hard stiff clay, stiff black cotton, hard red earth shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravel soil including refilling the sides of foundation in layer of 15m thick watering ramming depositing the surplus earth in the premises as directed by the departmental officers etc., complete complying with standard specification. |
| 23 | Lowering PVC/ DWSC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste.For depth upto 2m, 50mm to 75mm dia (OD) PVC pipe |
| 24 | Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.a. Upto 2.40m Depth. |
| 25 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers - Mixing by mechanical means |
| 26 | Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 10 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge.In Cement Mortar 1:5 |
| 27 | Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 28 | Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used , curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 29 | Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used , curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 30 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc., with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 31 | Reinforced Cement Concrete 1:1½:3 (One Cement, One and a half crushed stone sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including Super Plasticiser, mixing charges for machine mix,laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - machine mix |
| 32 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 33 | Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, ransportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., 2000 Lit |
| 34 | Supplying and fixing Mild Steel grills for windows, ventilators etc., complete complying with standard specifications and as directed by the departmental officers. |
| 35 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. |
| 36 | Supply and fixing of Manhole Cover SFRC 600mm x 600mm |
| 37 | Providing Rectification Works to Outer Steel Gates etc., Complete as per Quotation |
| 38 | Providing Electrical Service Works as per Labour Quotation etc., Complete |
| 39 | Add G.S.T. @ 18% Please Enable Macros to View BoQ information |