| 1 | Electrical Repair WorkProviding and spreading of approved hard broken granite metal of size ( 40-60 mm) in Substation area at DHH to a compacted thickness of 100mm alongwith sand spreading, including supply, transportation, unloading, spreading, bracing and levelling as per the direction of Engineer-in-charge. N:B:. a)All bids received will remain valid for a period as specified in the Contract Data after the deadline date for submission of bids and validity of bids can also be extended if agreed to by the bidder and the Department.(b) TDS of aerosol based fire extinguisher should be verified and approved by the Superintending Engineer, Electrical Circle (R&B) Odisha, Bhubaneswar before execution of the work. |
| 2 | Cost for painting the word DANGER with skull & BONES SIGN, AS PER is 2551, Shall be written in english/hindi/local language on all four sides of the fencing wall.To be used as safety signage. |
| 3 | S/I/T&C of CPRI Approved LT OUTDOOR floor mounted cubical type electrical panel made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder coated paint is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 1 set of 3P+N 65kA Type-I+II SPD with 63A 4P,MCB,10kA , C series in the incomer.Provision of ON/OFF/TRIP indication for all the feeders areto be given.Provision of R,Y,B indication for all the feeders are to be given.In commer-1: 01 number 4p 800A LSING microprocessor release MCCB,50 kA with Icu= Ics=100% .Make-Schneider(CVS) / ABB (Formula)/ Siemens (3VA) /Legrand (DPX3) Busbar- 04 numbers of 1000Amps aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator.Make of SPD-OBO/Dehn/Siemens/Schneider/ABB/LegrandOutgoing : 2 nos. of 630A 4P LSIG microprocessor release MCCB,36 kA with Icu= Ics=100% .Make-Schneider(CVS) / ABB (Formula)/ Siemens (3VA) /Legrand (DPX3) |
| 4 | Control cable trench 300mm width complete with cover slab,sand filling as per IS standard |
| 5 | Cost for Spare cable of DG of MCH Building for of following size.Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5 core, 185 Sq.mm.(for SNCU DG) |
| 6 | 3.5 core, 240 Sq.mm.(for other DG of MCH) |
| 7 | 3.5core, 300 Sq.mm.(1 span 30 mtr for MCH) |
| 8 | Supplying and making end termination with brass DOUBLE compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5core, 300 Sq.mm. |
| 9 | 3.5 core, 240 Sq.mm. |
| 10 | 3.5 core, 185 Sq.mm. |
| 11 | Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets. |
| 12 | Supply & fixing HT danger notice plate of 250 mm x 200mm, made of mild steel sheet of at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. (11000V) |
| 13 | Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m) |
| 14 | Providing Single Line Diagram on 5mm thick Aluminium sheet in A0 Size duly laminated. |
| 15 | Supplying and fixing of Shock treatment chart both in Regional, Hindi & English.and framed with 5mm thick glass as required. |
| 16 | Supply Surge protection Device (SPD) Clasee B+C , Type - I+II for handling Lightning surges of 10/350 μs & Switching surges of 8/20 μs waveform.Installed in DB and Sub DB. Technology (L-N)-MOV with built in thermal fuse, (N-PE)-Spark Gap Encapsulated / Non-exhausting, Maximum Continuous operating Voltage -320V per pole, Nominal Discharge Current In 30 kA (8/20 µsec), Maximum Discharge Current Imax 40 kA (8/20 µsec).Lightning Impulse Current 7 kA (10/350 µsec)/pole 25 kA (10/350 µsec) Total.Voltage protection level ,Up <1.3 KV, Response time ta -(L-N) -25ns ,(N-PE) <100 ns,Operating temperature range -(-)40°C to (+)80°C . Mounting on - Din Rail, Degree of protection of enclosure - IP 20,Standards/ Certifications - IEC 61643-1 in complete as per the direction of Engineer in charge. .Model : V25 B+C-3+NPE-320 with Transperant Enclosure.Make-Legrand/Siemens/Schneider/Equivalent. |
| 17 | Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 alongwith SPD complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year. |
| 18 | Cost of shifting of AC stabiliser from OT room to out side as per direction of EIC. |
| 19 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Vguard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materialsGROUP-A |
| 20 | GROUP-B |
| 21 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 22 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 23 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 24 | Circuit/submain wiring of 2 nos single core 1.5 sq. mm PVC FRLS insulated, copper conductor, single core cable for phase and neutral and 01 no of single core 1.5 sq. mm PVC FRLS insulated, copper conductor, single core cable for earth continuty conductor In 20 mm dia M S STEEL conduit (2X1.5+1X1.5)Make of wire - Finolex/Anchor/Polycab/HAVELLS/RR KABLE /KEI/Gloster/V-Guard Make of conduit -AKG / BEC/Precision /Norpak /Anchor /Kinjal |
| 25 | Circuit/submain wiring of 2 nos single core 2.5 sq. mm PVC FRLS insulated, copper conductor, single core cable for phase and neutral and 01 no of single core 1.5 sq. mm PVC FRLS insulated, copper conductor, single core cable for earth continuty conductor In 20 mm dia M S STEEL conduit (2X2.5+1X1.5)Make of wire - Finolex/Anchor/Polycab/HAVELLS/RR KABLE /KEI/Gloster/V-Guard Make of conduit -AKG / BEC/Precision /Norpak /Anchor /Kinjal |
| 26 | Circuit/submain wiring of 2 nos single core 4 sq. mm PVC FRLS insulated, copper conductor, single core cable for phase and neutral and 01 no of single core 1.5 sq. mm PVC FRLS insulated, copper conductor, single core cable for earth continuty conductor In 20 mm dia M S STEEL conduit (2X4+1X1.5)Make of wire - Finolex/Anchor/Polycab/HAVELLS/RR KABLE /KEI/Gloster/V-Guard Make of conduit -AKG / BEC/Precision /Norpak /Anchor /Kinjal |
| 27 | Circuit/submain wiring of 2 nos single core 6 sq. mm PVC FRLS insulated, copper conductor, single core cable for phase and neutral and 01 no of single core 2.5 sq. mm PVC FRLS insulated, copper conductor, single core cable for earth continuty conductor In 25 mm dia M S STEEL conduit (2X6+1X2.5)Make of wire - Finolex/Anchor/Polycab/HAVELLS/RR KABLE /KEI/Gloster/V-Guard Make of conduit -AKG / BEC/Precision /Norpak /Anchor /Kinjal |
| 28 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Tapping from 50mm x 6 mm bus bar to all sub panel |
| 29 | 100 bedded IPD/OPD Building & Other BuildingsSupply & Installation of 8 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.08 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 30 | Supply & Installation of 20 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.2 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 31 | Supply & Installation of 30 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 0.3 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 32 | Supply & Installation of 60 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 0.6 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 33 | Supply & Installation of 100 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 1 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 34 | Supply & Installation of 200 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 2 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 35 | Supply & Installation of 500 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 5 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 36 | Supply & Installation of 50 gm aerosol based Manual Fire Extinguisher (Duration:10-20 sec) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 5 years. Make-Pyrogen/Firepro/Stat-x |
| 37 | Supply & Installation of 3.3 Kg Manual aerosol based Fire Extinguisher covering 150m3 for big fire (Throwable unit) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 38 | Supply and installation of linear heat detection cable compatible with aerosol based fire extinguisher as per the direction of Engineer-in-charge. Make-Pyrogen/Firepro/Stat-x |
| 39 | MCH (G+6)Supply & Installation of 8 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.08 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 40 | Supply & Installation of 20 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.2 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 41 | Supply & Installation of 30 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 0.3 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 42 | Supply & Installation of 60 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 0.6 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 43 | Supply & Installation of 100 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 1 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 44 | Supply & Installation of 50 gm aerosol based Manual Fire Extinguisher (Duration:10-20 sec) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 5 years. Make-Pyrogen/Firepro/Stat-x |
| 45 | Supply & Installation of 3.3 Kg Manual aerosol based Fire Extinguisher covering 150m3 for big fire (Throwable unit) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 46 | Supply and installation of linear heat detection cable compatible with aerosol based fire extinguisher as per the direction of Engineer-in-charge. Make-Pyrogen/Firepro/Stat-x Please Enable Macros to View BoQ information |