|
| 1 | Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation board/slabs/ blanket any thickness including cover filllets complete all as specified and directed. |
| 2 | S&F for 5mm thick PVC hollow sheet ( the thickness of inner wall 0.7 to 1.00 mm) in wall panelling inclusive of solvent cement and filling at sitewith U clip or PVC frame as per specification and drawing complete all as specified and directed. |
| 3 | M&L 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work as in wall paneling complete all as specified and directed. |
| 4 | Dismantling timber framed in fillets,rails, posts rafters,purlines, etc under 40 sq cm in section complete all as specified and directed. |
| 5 | M&L second class Hardwood plain filllets, rectangular in section, clean swan, secured with nails exc 13 and n.exc 25 Sqm complete all as specified and directed. |
| 6 | M&L 18/19mm teak wood lipping 6mm thick for block board or veneered particle board complete fixed with nails complete all as specified and directed. |
| 7 | S & F Anodised aluminium snap grid frame work for false ceiling size of grid 605x605 mm and 4 mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 8 | Dismantling of plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed. |
| 9 | S&F Galvanised,corrugated mild steel sheeting of 0.63mm thick with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts and washers, in roofs, walls etc. with grade of zinc coating 275complete all as specified and directed. |
| 10 | S&F Plain, galvanised, mild steel sheeting of 0.63 mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 11 | M&L for preparation of new steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide premier.(camouflage pattern) complete all as specified and directed. |
| 12 | Dismantiling Wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 13 | S & F Roof trusses Fe 410W (grade-E-250)quality A (framed )trussed ,purlins crane gantries rails etc(beam tee angle channel or flat sections) complete all as specified and directed. |
| 14 | S&F in repair for second class softwood 1.218m x 0.198m x 8mm thick non glue laminated wooden boarding as in flooring including 0.6mm PE poly moisture foam as in underlay barrier of overlapping 20cm fix them with adhesive tape, boarding fix in floating manner complete all as specified and directed. |
| 15 | Taking down plastering, in cement mortar, complete all as specified and directed. |
| 16 | Demolition of Brickwork or stone/ boulder masonry built in cement mortar complete all as specified and directed. |
| 17 | M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width set in cement mortar 1:4 type C1 1:3:6 (20mm graded aggregate)complete all as specified and directed. |
| 18 | M&L for Rendering 10mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 19 | M&L for Rendering 15mm thick cement plaster 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 20 | M&L for preparation of new cement plastered surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of premier.(camouflage pattern) complete all as specified and directed. |
| 21 | Taking down chowkhat or door frames exc 1.5 sqm n exc 4 sqm each (withouttaking off shutters from the frame) complete all as specified and directed. |
| 22 | Taking down chowkhat or door frames n exc 1.5 sqm each (withouttaking off shutters from the frame) complete all as specified and directed. |
| 23 | S&F of powder coated (minimum thickness of powder coating 50 micron) aluminium anodised frame for doors, windows, ventilator, with one or more rebates incl joining cleat for fixing etc.complete all as specified and directed. |
| 24 | S&F of podwer coated (minimum thickness of powder coating 50 micron) Anodiesed Aluminium door shutters, aluminium section weighing 0.55Kg/m incl necessary jointing cleats, glazing clips, ruber neoprene packing, handles, 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed. |
| 25 | Hacking out old broken glass Exc 1.5 Sqm (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 26 | M&L Sheet glass of 5.5 mm thick,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed. |
| 27 | S&F Premium Roller Blinds Blackout Day & Night Window Shades | UV & Heat Protection Greenguard Certified , complete all as specified and directed. |
| 28 | S&F 150mm Aluminium anodised,barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 29 | S&F 200mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 30 | S&F In repair aluminium Door closer hydraulically regulated,extruded section body designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and directed. |
| 31 | M&L 9mm thick Plywood, grade BWR, type BB, fixed with nails to timber frame work complete all as specified and directed. |
| 32 | S&F for 5mm thick PVC hollow sheet ( the thickness of inner wall 0.7 to 1.00 mm) in wall panelling inclusive of solvent cement and filling at sitewith U clip or PVC frame as per specification and drawing complete all as specified and directed. |
| 33 | S&F for 1.00mm thick decorative Sunmica Laminated sheet wood grain, complete all as specified and directed. |
| 34 | M&L 1st class soft woodPlain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed. |
| 35 | M&L 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed. |
| 36 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 37 | M&L Securing glass of any description in existing wooden frames glazed with putty/ beads including removing loose or decayed putty/ beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work (New length of frame reputtied shall be measured) complete all as specified and directed. |
| 38 | M&L Including taking down of existing old unsv Point wiring and points using approved colour coding as per IS for modular switch and socket in concealed conduit with 1.5 Sqmm FRLS cable (multi-stranded) PVC insulated and sheathed electric cable 1100 volts drawn through PVC Conduit and including rigid 20 mm PVC concealed conduit and conduit Accessories ISI marked with valid CML No ( IS 9537-1983 for conduit and IS 3419: 1976 for conduit accessories ) meduim grade including fixing / grouting with mild steel / pressed steel sunken boxes (with earth dolly ) of suitable thickenees covered with suitable modular cover plate including runing up 1.5 sqmm multistanded copper conductor PVC insulated cable as earth continutiy conductor along with wiring and connecting to the common earth dolly for fixing the switches/sockets/regulators etc all as specified and directed at site for the follwings. Note: - 1. Modular cover plate is inclusive of the rated quoted by the contractor 2. switches and sockets shall be measured and paid separately. |
| 39 | One light/fan point controlled by one 5 Amps one way switch (3 Nos point Strip light ) |
| 40 | Four light Point controlled by one 5 Amps one way switch complete all as specified and directed. |
| 41 | One 3 pin socket outlet 5 Amps on independent board complete all as specified and directed. |
| 42 | One 3 pin socket outlet 5 Amps on same board complete all as specified and directed. |
| 43 | M&L Including taking down of existing old unsv Point wiring and points using approved colour coding as per IS for modular switch and socket in concealed conduit with 2.5 Sqmm FRLS cable (multi-stranded) PVC insulated and sheathed electric cable 1100 volts drawn through PVC Conduit and including rigid 20 mm PVC concealed conduit and conduit Accessories ISI marked with valid CML No ( IS 9537-1983 for conduit and IS 3419: 1976 for conduit accessories ) meduim grade including fixing / grouting with mild steel / pressed steel sunken boxes (with earth dolly ) of suitable thickenees covered with suitable modular cover plate including runing up 2.5 sqmm multistanded copper conductor PVC insulated cable as earth continutiy conductor along with wiring and connecting to the common earth dolly for fixing the switches/sockets/regulators etc all as specified and directed at site for the follwings Note: - 1. Modular cover plate is inclusive of the rated quoted by the contractor 2. switches and sockets shall be measured and paid separately. |
| 44 | S & F and taking down of Modular switch 1 way 6 A,1 module, 240 Volts complete all as specified and directed. |
| 45 | Supply & fix modular switch 1 way, 16 Amps, 1 modular (ISI marked).complete all as specified and directed. |
| 46 | Supply & fix modular socket, 6 Amps, 3 pin combind 2 module (ISI marked).complete all as specified and directed. |
| 47 | Supply & fix modular socket, 16 Amps, 3 pin combind 2 module (ISI marked).complete all as specified and directed. |
| 48 | Supply and fix modular cover plate with frame, 3 module. complete all as specified and directed. |
| 49 | Supply and fix modular cover plate with frame, 8 module.complete all as specified and directed. |
| 50 | Supply and fix modular metal flush box 3 module. complete all as specified and directed. |
| 51 | Supply and fix modular metal flush box 8 module. complete all as specified and directed. |
| 52 | S&F and taking down of LED COB focus light fittngs 7 Watt in white/warm white/Natural white lightcomplete all as specified and directed. |
| 53 | Supply & fix and taking down of LED 9 Watts Indoor Ceiling Spot Light/Focus Light/Track Light (White)|Flexibly Rotatable Light Head|for Kitchen,Living Rooms -Trackway Included (Black Body),complete all as specified and directed. |
| 54 | Supply and fixing LED Warm White luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface panel fittings with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.complete all as specified and directed. |
| 55 | S&F building LED outdoor strip light IP-65, 60 LEDs per meter, 14.4 watt in warm white complete all as specified and directed. complete all as specified and directed. |
| 56 | S&F and taking down of MCB DB sheet enclosure,Double door type, Triple pole and neutral 415V with 200 Amp rated bus bar suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed. |
| 57 | Supply and fixing and taking down of 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and currentcarrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed. |
| 58 | Supply & fixing and taking down of MCB TPN (40-63) Amp 240V, 10KA 'C' curve current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed. |
| 59 | M&L for and taking down of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed. |
| 60 | S&F Modular Switch socket Combination 16 Amp,6 Pin,3 Module flush type complete all as specified and directed. |
| 61 | S&F Modular white Cover plate with Frame complete all as specified and directed. (8 Module) |
| 62 | S&F Modular white Cover plate with Frame complete all as specified and directed. (6 Module) |
| 63 | S&F Modular white Cover plate with Frame complete all as specified and directed. (4 Module) |
| 64 | S&F Modular Metal flush box 4 module complete all as specified and directed. |
| 65 | S&F Modular Metal flush box 6 module Complete all as specified and directed by Engr-in-Charge. |
| 66 | S&F Modular Metal flush box 8 module complete all as specified and directed. |
| 67 | S&F building LED outdoor strip light IP-65, 60 LEDs per meter, 14.4 watt in warm white complete all as specified and directed. |
| 68 | Deduct Schedule of Credit of listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item Please Enable Macros to View BoQ information |