| 1 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed |
| 2 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed |
| 3 | Dismantling structural steel work including doors, gates and Window but excluding framed truss etc.complete all as specified and directed |
| 4 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed |
| 5 | Refixing except sheeting galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 6 | Material and labour for old size sub Class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar ( 1:6) having compressive strenght not less than 75 kg/Sq cm all as specified and directed. |
| 7 | Material and labour for 10 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and fair all as specified. |
| 8 | Material and labour Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thickwalls built in in cement mortar ( 1:6) having half brick wall |
| 9 | Material and labour Applying white wash newly plastered surface one coat of undecorated surface and two coat of sequent coat on walls complete all as specified and directed |
| 10 | Material and labour for preparing the new plastered surfaces and applying two coats of cement base paint on walls complete all as specified and directed. |
| 11 | Material and labour Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing (Grade A )Compound complete all as specified and directed. |
| 12 | Material and labour providing, cement concrete1:2:4 type B1(20mm graded aggregate) as in lintels upto 1.5m Clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. |
| 13 | Material and labour Mild steel barsTMT Bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending,mspirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 14 | Ditto, TMT Bar but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 15 | Material and labour Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) 25 mm thick complete all as specified and directed |
| 16 | Material and labour Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement to match + screed bed 1:6 (15mm thick) |
| 17 | Material and labour Glazed ceramic tiles in vertical surface 450x350x7 mmthick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thk backing coat CM 1:3 |
| 18 | Material and labour Cement concrete type C- 2,1:3:6 (40mm graded aggregate) 75 mm thick as in plinth protection complete all as specified and directed. |
| 19 | M &L for Non asbestos fibrecement buildingboards 4 mm thick of size 600mm x 600mm fixed orlaid/ inserted to timber/ GI/ Aluminium frameworkwith screwcomplete all as specified and directed. |
| 20 | Supply and fixed Anodised aluminium snap grid frame work for false ceiling all as specified Size of grid 605 x 605mm for celling with Gl frame work for seamless ceiling comprising of G l perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners wit mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 21 | Supply and fixed Pressed Steel Windows/Ventilator using box type hinges, MS Spring Latch, MS tower Bolt and telescopic stay complete complete all as specified and directed. |
| 22 | Supply and fixed 4.0 mm thick sheet glass ordinary/tinted quality and glazing with oil putty in squares exc 0.5 sq. m in each pane in squares. |
| 23 | Supplied and fixed Pressed steel frames of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, |
| 24 | Supply and fix, 40 mm thick, flush shutters, solid core construction, with particle board core and ply wood face panels commercial type on both sides all as specified and directed |
| 25 | Supply and fixed 35 mm thick 2nd class hard wood Glazed and skelton shutter(minimum three panel) open rebated and prepared to receive glass, gauze etc edges of the framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members as specified all as specified and directed |
| 26 | Supply and fixed Stainless steel wire cloth.0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 27 | Supply and fixed Butt hinges, medium weight, cold rolled mildsteel 100 mm, and fixed complete all as specified and directed. |
| 28 | Supply and fixed Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 29 | Supply and fixed Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified and directed. |
| 30 | Supply and fixed Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 31 | Material and labour for 15 mm thick Rendering (5mm thick CM 1:4 with WPC over a coat of 10mm thick CM 1:4) on other than fair faces of brickwork or concrete surface without using extra cement .complete all as specified and directed. For external surface |
| 32 | Supply only integral liquid integral waterproofing compounds to IS 2645 complete all as specified and as directed. |
| 33 | Material and labour for two coat of synthetic enamel paint over a coat of Pink Primer, including prepration of new untreated wooden surface over 10 cm width complete all as specified and directed. |
| 34 | Supply and fixed Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 35 | Supply and fixed Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 36 | Material and labour for two coat of synthetic enamel paint including prepration of old steel surface over 10 cm width complete all as specified and directed. |
| 37 | Material and labour for two coat of synthetic enamel paint including prepration of new surface over 10 cm width complete all as specified and directed. |
| 38 | Supply and fixed MILD Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 4923-1997(reaffirmed 2009) grade Yst-310 complete all as specified and directed |
| 39 | Supply and fixed and repair PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 40 | Supplying and laying and repairing of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified 16 mm Dia |
| 41 | Supply and fixed and repair Pillar taps 15mm, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed complete all as specified and directed |
| 42 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials all as specified and directed by engineer in charge. |
| 43 | Material and labour for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLH/S in and including concealed PVC conduit 20/25 mm dia medium duty ISI marked with all necessary fittings for mounting of modular switches/sockets including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light/ceiling fan/exhaust fan controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 complete all as specified and directed by Engr- in-charge. |
| 44 | All as per item No. 42 above but 3 pin 5 amps socket out let point with the same board with other switches with cables of 1.5 Sqmm size complete all as specified and directed. |
| 45 | All as per item No. 42 here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed. |
| 46 | Supply and fixed Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls complete for 4 modules complete all as specified and directed. |
| 47 | -do- all as per item No 45 above but for 6 modules complete all as specified and directed. |
| 48 | -do- all as per item No 45 above but for 8 modules complete all as specified and directed. |
| 49 | Supply and fixed ceiling rose, 3 ph plastic round PVC/polycarbonate isolated body for mounting ceiling fan/exhaust fan/light fittings complete all as specified and directed. |
| 50 | Supply and fixed modular cover plate with frame for fixing of modular switches/sockets for 4 modules complete all as specified and directed. |
| 51 | -do- all as per item No. 49 above but for 6 modules complete all as specified and directed. |
| 52 | -do- all as per item No. 49 above but for 8 modules complete all as specified and directed. |
| 53 | Supply and fixed switch piano modular flush type 5/6 Amps 230V AC complete one way complete all as specified and directed. |
| 54 | Supply and fixed modular socket 6A out let 2/3 pin 5 Amps flush type complete all as specified and directed. |
| 55 | Supply and fixed modular switch socket outlet multipurpose 3 pin 15 Amps and one pin 5 Amps controlled by one switch complete all as specified and directed. |
| 56 | Supply and fixed Fan step regulator, 120W - 2 module controlled by one switch complete all as specified and directed. |
| 57 | Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 30W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size |
| 58 | Supply and fixed surface and wall mounted LED batten 4feets with 1x20W indoor decorative luminaries with and including electronic driver and 1x20W LED lamp,pre wired including necessary electric connection copper flexible PVC cable of 0.5 sqmm 3 core not more than 1m in length from ceiling rose to light fittings. |
| 59 | Supply and fixed sheet metal enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified. |
| 60 | Supply and fixed MCB 6 to 32 amps single pole amp rating 240V, 10KA breaking capacity 'C' Curve complete all as specified. |
| 61 | Supply and fixed MCB DP 40 amps 240 volts 10KA breaking capacity 'C' Curve complete all as specified. |
| 62 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cableSupply and fixedoundation of poles and getting out in soft /loose soil complete all as specified and directed by Engr-in-Charge. |
| 63 | Material and labour for 40mm bore GI tubes light grade for cable protection inside in walls/ground making good surface with all fixing accessoires (clamps, nut, bolt and washer etc) complete all as specified and directed. Make Jindal/Tata/Nezone |
| 64 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm complete all as specified and directed by the Engr-in-Charge |
| 65 | Removing excavated materials not exc 50 mtr and depositing where directed at a level next 1.5mtr above the starting point complete all as specified and direced by the Engr-in-Charge |
| 66 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 67 | Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 68 | Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed. Please Enable Macros to View BoQ information |